| 1 | Supply, Installation, Testing & Commissioning of 82.5 KVA Silent Water Cooled, Silent DG Set. Complete in all respects as per direction of E/I. (AOR) |
| 2 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 ( Grandley, Gloster, Kalinga, Havells, Nicco, Plaza, KEI Make) i) 70 sqmm x 3.5 core |
| 3 | ii) 50 sqmm x 3.5 core |
| 4 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504 70 Sqmm |
| 5 | iii) 50 sqmm |
| 6 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. PS. No. 725 (B) |
| 7 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects. PS Nos. 716 |
| 8 | S&F of 100 Amp. four pole change over switch on 40mm x 40mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. Ps No. 378 |
| 9 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve as per PS No. 1020 (A) |
| 10 | Wiring points for light with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 FR PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and ceiling rose/angle/batten holder 3mm thick phenolic laminated backelite sheet etc.Complete in all respects as per direction including mathcing colour wash. P.S. No. 138C |
| 11 | Wiring points for Fan/fresh air fan (light duty exhaust fan) with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 FR PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and ceiling rose 3mm thick backelite sheet etc.Complete in all respects as per direction including mathcing colour wash. P.S. No. 140C |
| 12 | Wiring points for Plug with 1 sq. mm. FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 FR PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and socket etc.Complete in all respects as per direction including mathcing colour wash. P.S. No. 141C |
| 13 | Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. P.S No. 1405 Cat AAA |
| 14 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. PS No. 1002 Cat A |
| 15 | Supply and fixing of power plug with 15A / 250 V flush type switch and 5 pin 15 A / 250V flush type socket in suitable M.S. box of 175 mm x 100 mm x 50 mm size with Bakelite sheet cover 3 mm. thick fixed with brass machine screws and cup washer. P.S. No. 1139 |
| 16 | S & F surface/Flush mounting 8ways V TPN distribution board without additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. PS No.1028B Cat A |
| 17 | S/F of fan regulator dimmer 250/300W ISI mark on the existing switch board including making connection T&P etc. for proper completion of work to the satisfaction of Engineer of work. PS No. 1203 |
| 18 | Supply, Installetion, Testing & Commissioning of 450 mm dia 1400 R.P.M Exhaust fan with lovuvred shutters (AOR) |
| 19 | Supply and Fixing of Ceiling fan 1200 mm dia ISI marked Make-Baja, Crompton, Havells or equivalent make. (AOR) |
| 20 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other rameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 100 Amp. MCCB-1 No & 63 Amp. MCCB-3 NosCat. B. Pannel Cubicle Type PS No.812(C) |
| 21 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.DSR-2018 1.17. 4 x 10 sq. mm 1.17.28 |
| 22 | 4 x 16 sq. mm+2x6 Sqmm 1.14.11 |
| 23 | 3 x 2.5 sq. mm DSR-2018 1.17.12 |
| 24 | 3 x 4 sq. mm DSR-2018 1.17.21 |
| 25 | 3 x 6 sq. mm DSR-2018 1.17.30 |
| 26 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.DSR-2018 1.23. 15/16 A switch DSR-2018, 1.23.3 |
| 27 | 3 pin 5/6 A socket outlet DSR-2018, 1.23.4 |
| 28 | 6 pin 15/16 A socket outlet DSR-2018, 1.23.5 |
| 29 | 5/6 amps switch DSR-2018, 1.23.1 |
| 30 | Supply of DG Set Oprateror 01 Nos. Complete in all respects as per direction of (AOR)Staff 100 % verified by department. @ 33475.00 each |
| 31 | Supply and laying 90 mm dia DWC ( Double wall corrugated pipe across the road by Trenchless method (Manual). Complete in all respect as per direction of E/I. (AOR) |
| 32 | Supplying and laying of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete asrequired.DSR 18 14.16.2. 90 mm dia ( OD-90 mm & ID 76 mm nominal) Please Enable Macros to View BoQ information |