| 1 | Wiring points for light with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable (drawn through existing concealed PVC conduit) with 1.5 sqmm PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit and 5 amp flush type switch & ceiling rose/angle/batten holder fixed on 3mm thick phenolic laminated backelite sheet with brass machine screw and brass cup washers mounted over existing MS switch board box/junction box with supply of all material, labour and T&P etc. required for proper completion of the work as directed at site by the Engineer I/C PS No. 174 (C) |
| 2 | Wiring points for ceiling fan (light duty exhaust fan) with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable (drawn through existing concealed PVC conduit) with 1.5 sqmm PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit and 5 amp flush type switch & ceiling rose/angle/batten holder fixed on 3mm thick phenolic laminated backelite sheet with brass machine screw and brass cup washers mounted over existing MS switch board box/junction box with supply of all material, labour and T&P etc. required for proper completion of the work as directed at site by the Engineer I/C PS No. 177 (C) |
| 3 | Wiring points for Plug point with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable (drawn through existing concealed PVC conduit) with 1.5 sqmm PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit and 5 amp flush type switch & ceiling rose/angle/batten holder fixed on 3mm thick phenolic laminated backelite sheet with brass machine screw and brass cup washers mounted over existing MS switch board box/junction box with supply of all material, labour and T&P etc. required for proper completion of the work as directed at site by the Engineer I/C PS No. 178 (C) |
| 4 | Wiring point for exhaust fan with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable in 2mm thick PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit,15 A piano type switch & ceiling rose on 3mm thick phenolic laminated backelite sheet etc. complete in all respects including matching colour wash.(Heavy duty Ex. Fan) PS No. 144 (C) |
| 5 | Supply and fixing of power plug with 15A/250 V flush type switch and 5 pin 15A/250V flush type flush universal socket in suitable MS box of 175mm x 100mm x 50 mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. PS No. 1139 |
| 6 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. PS 291 |
| 7 | Supply and wiring of submains with 2 nos. 4 sq mm and 1 no 2.5 sq mm FRLSH PVC insulated copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. PS 291(A) |
| 8 | Supply and wiring of submains with 2 nos. 6 sq mm and 1 no 4 sq mm FRLSH PVC insulated copper conductor cable. in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. PS 291(D) |
| 9 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. DSR Electricals 2018 No. 9.3 a) 2 X 25 sq. mm (9.3.2) |
| 10 | c) 4 X 16 sq. mm (9.3.29) |
| 11 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 12 | Location and pin pointing of 11KV HT Cable fault exposing the same in the underground 11KV Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable fault locator) (AOR) |
| 13 | Location and pin pointing of LT Cable fault exposing the same in the underground LT Cables including digging of trench upto the depth of the cable, cutting the faulty cable and sealing of the faulty cable and sealing of the faulty cable, by expert technical staff. (AOR) |
| 14 | Repairing of 11KV Fuse wire/Jumper i/c supply & fixing of required size conductor, fuse wires of 11KV Line/DP Structure of Transformer by taking shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, Shoes and other necessary items. (AOR) |
| 15 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501 a) 25 sqmm x 3.5 core |
| 16 | 50 sqmm x 3.5 core |
| 17 | 16 sqmm x 2 core |
| 18 | 25 sqmm x 2 core (AOR) |
| 19 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making onnection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504a) 25 sqmm |
| 20 | 50 sqmm |
| 21 | 16 sqmm |
| 22 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. i) 90 mm dia (OD-90 mm & ID-76 mm nominal) DSR Electrical-18 pg-52, I.No.14.16.2 |
| 23 | 63 mm dia (OD-63 mm & ID-50 mm nominal) DSR Electrical-18 pg-52, I.No.14.16.1 |
| 24 | Supply and fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect CAT- AAA PS 1443 |
| 25 | Supply of ceiling fan 1200 mm dia (ISI Mark) Make- Crompton/Havells/Bajaj/Usha or equivalent (AOR) |
| 26 | Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect.PS NO 1116 |
| 27 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. DSR Electrical 2018/ I.No. 1.45 P-8 |
| 28 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect complete in all respects. P.S.No. 1413 CAT AAA |
| 29 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument &instrument box with CTs etc. in case of TPN, complete in all respect. PS No. 807 e (ii) 40 A TPN |
| 30 | S/F of Copper Cable of size 2.5 mm x 3 Core. Complete in all respect (AOR) |
| 31 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS 725 (B) |
| 32 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects. PS No. 716 |
| 33 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 34 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate moorum screening, red bajri and labour required. i) bituminious portion (AOR) |
| 35 | water bound macadam (AOR) |
| 36 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 37 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 38 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 39 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) Please Enable Macros to View BoQ information |