| 1 | Civil Works: |
| 2 | Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety. In ground floor(a) 1:3:6 proportion |
| 3 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(f) 25mm to 30mm thick shuttering without staging in foundation etc |
| 4 | Hire and Labour Charges for shuttering with hard wood for precast R.C. Slab curved, or stright and striking out the same including fitting, fixing the precast slab in position with necessary carriage and haulage, hosting etc, complete in all respect. (only the area in contact with concrete to be measured) |
| 5 | Screed concrete on roof with cement concrete (1:2:4 ) including admixture of damp proof materials as per manufactures specification laid in panels as directed including cleaning, chipping and applying cement slurry @ 1.75 kg/SQM. Providing ghoondies at junctions with parapet etc. Shapping and finishing at mouths of rain water pipes complete with top finishing with cement punning not more than 1.5 mm thick, curring complete as per direction of E.I.C. (Same as Artificial stone).[Artificial Stone Flooring (Sl. no. 4 at Page no. 22 3rd CORRI.) minus Neat Cement Punning (Sl. 8 at Page no. 166)= Rs. 330.00 - Rs. 34.00 = 296.00].Average 35 mm thick. |
| 6 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge.All floors. |
| 7 | Application of priming coat for standard bituminous waterproofing treatment over flat roof with Bitumen primer of approved brand fufilling the provision of I.S.1346-1991 & 3384-1986 applied @ 0.27 Liters /SQM overcleanand prepared roof surface complete as per satisfaction of the Engineer - in - Charge. |
| 8 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per SQM & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/SQM of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage,complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) |
| 9 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation,basement and upto roof of ground floor/upto 4 m.(i) Tor steel/Mild Steel.II. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL |
| 10 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no separate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for EACH additional floor or 4m. beyond initiial 8m. or part thereof.I) For structural members of specified sections weighing less than 22.5 Kg./m |
| 11 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface.]In ground floori) With 1:6 cement mortar(b) 20 mm. thick plaster. |
| 12 | (c) 15 mm. thick plaster |
| 13 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, etc. NOTE: Cement 0.152 CUM per SQM |
| 14 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc |
| 15 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.On steel or other metal surface :With super gloss (hi-gloss) -Two coats (with any shade except white) |
| 16 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper/Acrylic emulsion paint including scrapping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of EIC. (a) One coat (i) Water based interior grade Acrylic primer |
| 17 | Applying Acrylic emulsion paint of approved make and brand on walls and ceiling including sand papering in intermidiate coats including putty (to be done under specific instruction of the Superintending Engineer)., (Two coats),(i) Standard Quality. |
| 18 | Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scrapping and preparing the surface throughly, complete as per manufacturer’s specification and as per direction of the Engineer-in-Charge. In ground floor.(a) One coat |
| 19 | Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (a) Normal Acrylic Emulsion.In ground floor. |
| 20 | Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary. (Payment to be made on the length of individual lines of wire.) |
| 21 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide EACH and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood vveneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.In ground floor.(a) 35 mm thick shutters (single leaf) |
| 22 | PVC Door 30 mm thick, Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C.multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to EACH other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in EACH corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strongenough to with stand wear and tear. The rate is inclusive of cost of all materials,labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete. |
| 23 | Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. |
| 24 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).b) Movable door shutter.Top rail |
| 25 | Bottom rail |
| 26 | Lock rail |
| 27 | Door vertical |
| 28 | Glazing clip |
| 29 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.iii) weather gasket / wool pile for door vertical |
| 30 | Labour charge for fabrication and installation of composite door, window, Partitions made from annodized extruded alloy aluminium sections for the following units:-(D) Partly glazed and partly panelled partition or fixed glazing made of extruded and anodised alloy aluminium sections, fabrications after cutting to proper shape and size, drilling and aligning fitted with inbuilt locking arrangement cutting the glass / board (prelaminated / particle / block) to requisite shape and size moulding the edges fitted and fixed glazing clips and dry set neoprine /EPDM gasket, along with all other necessary arrangements for fixing the partition to walls, floors, beams,columns polysulphide sealant for water proofing if necessary complete in all respect as per drawing and specifications and direction of the Engineer in charge. The rate includes the hire charge of all tools and plants, adhesive, joineries such as screw, fastener but excluding the cost of extruded aluminium sections, EPDM gasket, glass, board, glazing clips, locking arrangement, etc.I) For partitions using section of size:a) 63.5 mm x 38.10 mm |
| 31 | Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board,10-12 Micron thickness Annodizing film.Natural white.a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 SQM Kg. 391 391 391 391 391 391 391 391 391 391 391 401 391 391 391(unit wt of Top, bottom & side member @1.366 kg/m ; intermediate member @ 1.443 kg/m; glazing clip: 0.167 kg/m respectively)[Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.7 Kg per Sq.M] |
| 32 | (B) Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand.B. Colour |
| 33 | Supplying concealed type heavy duty PVC headed aluminium tower bolt for double leaf doors as per approved make and brand as per direction of Engineer-in-Charge.(a) 200 mm long |
| 34 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.(iii) 5mm thick clear glass. |
| 35 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.(a) Upto 20 users:-(i) Within a lead of 150 metre |
| 36 | Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats and repairing the pit as necessary including fitting the slab. |
| 37 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.450 mm X 300 mm size. |
| 38 | Supplying, fitting and fixing urinal flush pipe fittings of approved brand.C.P. urinal flush pipe fittings range of two |
| 39 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.C.P. Flush Pipe |
| 40 | Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand). |
| 41 | Supplying, fitting and fixing bib cock or stop cock. (c) (i).Chromium plated Bib Cock (angular shape with wall flange [Equivalent to Code No.5037 & Model - Florentine of Jaquar or similar brand]. |
| 42 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)For Exposed Work PVC Pipe. 15 mm |
| 43 | For Exposed WorkPVC Pipe. 25 mm |
| 44 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer2000 Litre capacity |
| 45 | Labour for hoisting plastic water storage tank.Above 1500 Litre Upto 5000 Litre capacityUpto 1st story from G.L. |
| 46 | Labour for punching hole in plastic water storage tank upto 50 mm dia. Please Enable Macros to View BoQ information |