| 1 | Excavation by manpower with tools and eqpts standard/specifications for making trenches and not exceeding 1.5 m wide and not exceeding 1.5 m in depth without hampering the existing services like PNG, NFS, Water supply line, Electric supply line for relaying of existing cable, taking out existing cable, HV cable cover, stacking and depositing to MES yard at directed place incl getting out Soft/Loose soil complete all as specified by Engr-in-charge. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested all as specified and directed. |
| 3 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 4 | Supply and laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable all as specified. |
| 5 | M&L for laying of Sub class 'B' size well burnt brick laid flat in trenches as protection to LT cable complete all as specified and as directed. |
| 6 | Supply, laying and testing cable XLPE Insulated ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 3.5 x 185 sqmm size of cable complete all as specified and directed. |
| 7 | Supply, laying and testing cable XLPE Insulated ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 3.5 x 150 sqmm size of cable complete all as specified and directed. |
| 8 | Supply, laying and testing cable XLPE Insulated ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 3.5 x 25 sqmm size of cable complete all as specified and directed. |
| 9 | Supply, laying and testing cable XLPE Insulated ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 2 x 16 sqmm size of cable complete all as specified and directed. |
| 10 | Supply, laying and testing cable XLPE Insulated ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 2 x 10 sqmm size of cable complete all as specified and directed. |
| 11 | Supply, laying and testing cable XLPE Insulated ,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 2 x 4 sqmm size of cable complete all as specified and directed. |
| 12 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by ENgr-in-charge |
| 13 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of GI pipe and LT cables along the pipe for 50mm dia GI Pipe complete all as specified and directed |
| 14 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of GI pipe and LT cables along the pipe for 100mm dia GI Pipe complete all as specified and directed |
| 15 | S&F GI tubing light grade galvanised with all fittings & fixed complete wall/pole for 40mm bore complete all as specified and directed. |
| 16 | S&F GI tubing light grade galvanised with all fittings & fixed complete wall/pole for 50 mm bore complete all as specified and directed. |
| 17 | S&F GI tubing light grade galvanised with all fittings & fixed complete wall/pole for100 mm bore complete all as specified and directed. |
| 18 | M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in foundation/surface repair etc complete all as specified and directed. |
| 19 | S&F cable route indicator for LT, 6mm thick CI plate of size 100mm dia welded to MS angle iron 50mm x 50mm x 6mm embedded in PCC 1:3:6 type C-1 block size 150mm x 150mm x 160mm complete all as specified and directed. |
| 20 | Supply, installation, commissioning and testing, in repair, Junction Box , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply),CPRI approved, plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-(a) Incoming supply:- (i) Mains incomer, 125 A, 25 kA, 4-pole MCCB with adjustable thermal-magnetic release - 01 No (ii) Indicating lamp Neon type for R-Y-B - 3 Nos (vi)Extended rotary handle & spreader terminals for above MCCB-01 Nos (vii) 6 A TP MCB-01 NosMAIN BUSBAR SIZE- 25 X 10 mm. EC grade aluminium busbarsMAIN BUSBAR SIZE (For neutral)-25 X 10 mm. EC grade aluminium busbarsEARTHING BUS 25 X 5 mm. EC grade aluminium busbarsPANEL MOUNTING-Floor mountedCABLE ENTRY-Bottom for both incoming and outgoingPANEL FABRICATION-From 11G CRCA sheet steelFINISHING-Powder coating (min. 80 micron) after 7-tank process to shade RAL-7035Size of Junction Box shall be 850mm x 800mm x 450 mm |
| 21 | S&F, in repair, MCCB 3 Pole 415 volt Fixed type 125 Amps with breaking capacity 36 KA Complete all as specified and directed. |
| 22 | S&F, in repair, MCCB 3 Pole 415 volt adjustable type 160 Amps with breaking capacity 36 KA Complete all as specified and directed. |
| 23 | S&F, in repair, MCCB 4 Pole 415 volt adjustable type 160 Amps with breaking capacity 36 KA Complete all as specified and directed. |
| 24 | S&F, in repair, MCCB 4 Pole 415 volt adjustable type 200 Amps with breaking capacity 36 KA Complete all as specified and directed. |
| 25 | S&F, in repair, MCCB 4 Pole 415 volt adjustable type 250 Amps with breaking capacity 36 KA Complete all as specified and directed. |
| 26 | S&F, aluminum lugs for cable size 25 sqmm complete all as specified and directed. |
| 27 | S&F, aluminum lugs for cable size 35 sqmm complete all as specified and directed. |
| 28 | S&F, aluminum lugs for cable size 50 sqmm complete all as specified and directed. |
| 29 | S&F, aluminum lugs for cable size 70 sqmm complete all as specified and directed. |
| 30 | S&F, aluminum lugs for cable size 120 sqmm complete all as specified and directed. |
| 31 | Supply, installation, commissioning and testing, in repair, Main Panel board, LT (415 Volts, 50 Hz , 3-phase, 4 wire supply),CPRI approved, plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-(a) Incoming supply:- (i) Changeover switch of cap 630 A, 80 x 10 mm. EC grade aluminium busbars of 04 strip - 01 Nos (ii) Mains incomer, 630 A, 25 kA, 4-pole MCCB with adjustable thermal-magnetic release - 01 No (iii) MFM without RS-485 port, class - 1.0- 01 Nos (iv) Indicating lamp Neon type for R-Y-B - 3 Nos (vi)Extended rotary handle & spreader terminals for above MCCB-01 Nos (vii) 32 A TP MCB-01 Nos (viii)20 A SP MCB-01 Nos (ix) CT - 400 / 5 A, class - 1.0-03 Nos.(b) Outgoing supply:- (i) MCCB, thermal and magnetic setting, 3 pole, AC, 415volts,315 Amp rating, 25KA rupturing capacity - 02 Nos (ii) MCCB, thermal and magnetic setting, 3 pole, AC, 415volts, 160 Amp rating, 25KA rupturing capacity - 03 Nos (ii) Extended rotary handle for above MCCB - 01 Nos (iii) Wire - 16 sq. mm. for power wiring (iv) Terminal connectors for power connections (v) Digital street light timer switch alongthwith contactor 40A, 220 V AC-3 complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |