| 1 | Material and labour for Point wiring for complete with PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS-694, 1.5 sqmm (nominal area) ( Phase- R, Y , B, Neutral- Black), drawn through and including non metallic PVC casing- capping (not less than 20mm wide) (ISI marked) and accessories on surface of wall/roof with sunken type pressed steel/welded terminal boxes made out of 1.6mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor 1.5sqmm as earth continuity conductor (green colour) and connecting to common earth dolly complete all as specified and as directed including taking down copper/aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc for one light / exhaust fan/ ceiling fan point, controlled by one, one way switch complete all as specified and as directed by Engineer-in-Charge. Make of Cable- Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GEMake of PVC Casing Capping -Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 2 | All as per item No.1 here-in before but for bell point controlled by one, one way bell push button. |
| 3 | All as per item No.1 here-in before but One 3 pin, 5/6 Amps socket outlet point on the independent board |
| 4 | All as per item No.1 here-in before but for one 3 pin, 5/6 Amps socket point, on same board with other switches controlled by one, switch. |
| 5 | All as per item No. 1 described here - in - before but for 3 pin 15/16 Amps switch socket combination on independent board with 2.5sqmm copper cable single core and provision of 2.5sqmm PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete. |
| 6 | All as per item No. 1 described here - in - before but for 3 pin 15/16 Amps switch socket combination on independent board with 4.0 sqmm copper cable single core and provision of 4.0 sqmm PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete. |
| 7 | Supply and fix Switch Piano, flush type, single pole, one way, 5 Amps, 240 volts, ISI marked complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 8 | Supply and fix bell push, flush type, single pole, one way, 5 Amps, 240 volts, ISI marked complete all as specified and as directed.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 9 | Supply and fix Call bell electric (Ding Dong type) suitable for working on 230 volts AC supply multi music type complete all as specified and as directed. Make: Anchor Door Bell (38916)/ Havells Rubio (AHLLXR000)/ SSK |
| 10 | Supply and fix ceiling rose, surface type bakelite, 3 plate, PVC/Polycarbonate type 65x32mm with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge.Make: Legrand /crabtree/ Honeywell/ Anchor |
| 11 | Supply and fix Switch Piano, flush type, single pole, one way, 15/16 Amps, 240 volts, ISI marked complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 12 | Supply and fix socket outlet, 3 Pin, 5 Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 13 | Supply and fix socket outlet, combination 15/16 Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 14 | Supply and fix stepped type electronic fan regulator on existing phenolic laminated sheet ,100W, 230 V etc complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 15 | Material and labour for Point wiring for complete with PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS-694, 1.5 sqmm (nominal area) ( Phase- R, Y , B, Neutral- Black), drawn through in and including (medium grade) rigid non metallic PVC conduit pipe, not less than 20 mm size ISI marked with conduit accessories / fittings / junction box / inspection covers etc of ISI marked and cutting chases for concealed conduit with all surfaces by means of screws and sunk / cup washers, with Modular metal flush box including white cover plate with frame for mounting of switches sockets fan regulators etc including 1.5 sqmm, 1100 volts grade PVC insulated FRLS unsheathed flexible, multi stranded copper conductor cable (green colour) as continuous earthwire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end and including taking down copper/aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. for one light / Fan / Exhaust fan, controlled by one, one way switch all as specified and as directed Make of Cable- Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GEMake of PVC Conduit -Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 16 | All as per item No.15 here-in before but for bell point controlled by one, one way bell push button. |
| 17 | All as per item No.15 here-in before but One 3 pin, 5/6 Amps socket outlet point on the independent board |
| 18 | All as per item No.15 here-in before but for one 3 pin, 5/6 Amps socket point, on same board with other switches controlled by one, switch. |
| 19 | All as per item No. 15 described here - in - before but for 3 pin 15/16 Amps switch socket combination on independent board with 2.5sqmm copper cable single core and provision of 2.5sqmm PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete. |
| 20 | All as per item No. 15 described here - in - before but for 3 pin 15/16 Amps switch socket combination on independent board with 4.0 sqmm copper cable single core and provision of 4.0 sqmm PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete. |
| 21 | Supply & Fix ceiling fan regulator modular type two module AC, 240 volts 50 HZ, electronic step type complete all as specified and as directed by Engineer-in-Charge. Make : legand/havells/crabtree/Havells/SSK |
| 22 | Supply and fix Modular type bell push,one module, for call bell ,single pole, one way 6 Amps, 240 volt, 50Hz complete all as specified and as directed by Engineer-in-Charge.Make:Anchor / Legrand / Havells/.Crabtree/Leader |
| 23 | Supply and fix Modular type socket outlet 15/16 Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 24 | Supply and fix Modular type socket outlet 15/16 Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 25 | Supply and fix Modular type socket outlet 5 Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 26 | Supply and fix Modular type, switch single pole, one way, 6 Amps, flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 27 | Supply and fix Modular type switch single pole one way 15/16 Amps, flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 28 | Cutting chases with dust free cutting machine, pinning in making good the disturbed surface of wall / ceiling and pointing in cement mortar 1:3 to cutting chases for concealed conduit wiring, etc., and making good etc of girth not exceeding 10 cm girth all as specified and as directed by Engineer-in-Charge. |
| 29 | Supply and fix angle holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge.Make: Anchor / Legrand / Havells/.Crabtree/Leader |
| 30 | Supply and fix 100 watts LED high bay light fitting(asjustable type using hook/ cradle mounting options), 240 volts, 50Hz, AC supply complete with all accessories internally prewired and including electrically connection with cable of size 0.5 Sqmm (nominal area) including hanging arrangments and taking down existing light fittings etc complete all as specified and as directed by Engineer-in-Charge. Make : Philips Cat part No BY515P LED150S , Syska Cat Part No : UFO-E HI-BAY 100W and Bajaj Cat part No BGHBM 100WLED XE or equivqlent in Shakti/Wipro |
| 31 | Supply and fix 4ft, 6500K Inverter LED Batten lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including 02 Nos of PVC square /round boxes , screws clips including hanging arrangments and taking down existing light fittings etc complete all as specified and as directed by Engineer-in-ChargeMake: Shakti Cat part No. SZSLBMX018-iBB, Havells Cat Part No. LHEXASP7IN1W020 or equivqlent in Philips/Wipro |
| 32 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection, connection with three core copper flexible cable 16/0.20 mm from ceiling rose to fitting including hanging arrangments and taking down existing light fittings etc complete all as specified and as directed by Engineer-in-Charge.Make : Philips / Bajaj / Wipro |
| 33 | Supply and fix LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size including taking down existing light fittings etc complete all as specified and as directed by Engineer-in-Charge.Make : Phillips Cat No RC380B LED36S -6500 G4 L60 W60 PSU OD or equivalent of Havells / Crompton Greaves. |
| 34 | Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including hanging arrangments and taking down existing light fittings etc complete all as specified and as directed by Engineer-in-ChargeMake : Shakti Cat No SZSLAMX036-HLO or equivalent of Havells/Philips |
| 35 | Supply and fix round/square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp including connecting up with three core flexible copper conductor cable of suitable size including hanging arrangments and taking down existing light fittings etc complete all as specified and as directed by Engineer-in-ChargeMake: Havells Cat No LHEBLEP5IN1W020 or equivqlent in Philips/Wipro |
| 36 | Supply and fix LED light fitting 9W/10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including hanging arrangments and taking down existing light fittings etc complete all as specified and as directed by Engineer-in-Charge.Make: Philips/wipro/crompton. |
| 37 | Supply and fix Indoor Decorative light, wall mounting, metal , glass home , 220-240V with B22 LED bulb of 9 Watts including connecting up with three core flexible copper conductor cable of suitable size including taking down existing light fittings etc complete all as specified and directed by Engr-in-charge.Make: Havells cat part no. LHFOAJE1TZ1I060 or equivalent of wipro/philips |
| 38 | Supply & Fix LED Wall light/Picture light 15W, aesthetically designed with multiple body colour option, high efficiency LED, opaque diffuser, inbuilt driver, suitable for highlighting wall hangings including taking down existing light fittings etc complete all as specified and directed by Engr-in-charge.Make: Shakti cat part No. SZWPFPX015 or equivalent of wipro/philips/Havells |
| 39 | Supply and fix in repairs Sheet metal enclosure concealed to the wall for 12 way Distribution Boards (DB’s), double door, single pole & neutral with 100 amps rated bus bar, suitable for fixing MCBs/RCBOs complete all as specified and as directed by Engineer-in-Charge. Make: Havells / Legrand / L&T |
| 40 | Supply and fix in repairs double door, sheet metal enclosure, powder coated concealed to the wall for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 100 amps rated bus bar 230 volt conforming to IS 13032-199 etc complete all as specified and as directed by Engineer-in-Charge. Make: Havells / Legrand / L&T |
| 41 | Supply and fix in repairs double door, sheet metal enclosure, powder coated concealed to the wall for MCB DB SPN 4 way fitted with neutral link, earth bar , din rail and 100 amps rated bus bar 230 volt conforming to IS 13032-1991 including taking down etc complete all as specified and as directed by Engineer-in-Charge. Make: Havells / Legrand / L&T |
| 42 | Supply and fix in repairs double door, sheet metal enclosure, powder coated concealed to the wall for MCB DB TPN 4 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 415 volt conforming to IS 13032-1991 including taking down etc complete all as specified and as directed by Engineer-in-Charge. Make: Havells / Legrand / L&T |
| 43 | Supply and fix in repairs double door, sheet metal enclosure powder coated DB VTPN 4 way with 200 Amps rated bus bar, 415 volt, vertical type, IP 43 protection with provision for MCCB as incomer upto 125 Amp and SP/TP MCB as outgoing, flush in walls including making good of disturbed surface to match with existing surface including taking down etc complete all as specified and as directed by Engineer-in-Charge. Make: Havells Cat part No. DHDLVDRBATFO04, L & T DBVTM004GD or equivalent Legrand/ CG / Havells / ABB / Siemens / Schneider |
| 44 | Supply and fix in repairs MCCBs 63 Amps, 16 KA, 4 pole with adjustable thermal and magnetic settings etc complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / L&T / Havells / ABB / Siemens / Schneider |
| 45 | Supply and fix in repairs MCB TPN, 40 Amps to 100 Amps, 415 volts,10 KA etc complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / L&T / Havells / ABB / Siemens / Schneider |
| 46 | Supply and fix in repairs MCB SPN 25 Amps to 32 Amps, 240 volts,10 KA etc complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / L&T / Havells / ABB / Siemens / Schneider |
| 47 | Supply and fix in repairs MCB SP, 6 Amps to 32 Amps, 240 volts,10 KA etc complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / L&T / Havells / ABB / Siemens / Schneider |
| 48 | Supply and fix in repairs wall mounted fan with powder coated guards and blades of approved colour, AC single phase, 230 volts, 50Hz, 400mm sweep with adjustable verticle angles & three speed controls mounted within reach of hands with necessary connecting cables recommended/ provided by manufacturer complete. Make: Havells Cat Part No. FHWSW4SIVR16 or equivalent Almonard/ Bajaj/ Khaitan as approved.Note: Old fan will be deposited in MES Store yard. |
| 49 | Supply and fix in repairs air ventilation fan 250 mm sweep, rectangular in shape, suitable for window mounting complete with automatic louver shutter,PVC body, white colour 230V, single phase 50HZ AC supply complete all as specified and directed. Make: Havells/ Crompton/ Bajaj/UshaNote: Old fan will be deposited in MES Store yard. |
| 50 | Supply and fix in repairs air ventilation fan 200 mm sweep, rectangular in shape, suitable for window mounting complete with automatic louver shutter,PVC body, white colour 230V, single phase 50HZ AC supply complete all as specified and directed. Make: Havells Cat Part No. FHVTMDXWHT08 or equivalent Crompton/ Bajaj/Usha.Note: Old fan will be deposited in MES Store yard. |
| 51 | Supply and fix in repairs air ventilation fan 300 mm sweep, rectangular in shape, suitable for window mounting complete with automatic louver shutter,PVC body, white colour 230V, single phase 50HZ AC supply complete all as specified and directed. Make: Havells/ Crompton/ Bajaj/UshaNote: Old fan will be deposited in MES Store yard. |
| 52 | Supply & fix in repairs exhaust fans AC single Phase 230/240 V of size 300 mm sweep with a robust metal body finished with corrsion resistant powder coating along with inbuilt thermal overload protection for saftey against overheating complete all as specified and as directed by Engineer-in-Charge.Make: Havells/ Crompton/ Bajaj/UshaNote: Old fan will be deposited in MES Store yard. |
| 53 | Supply & fix exhaust fans AC single Phase 230/240 V of size 230 mm sweep with a robust metal body finished with corrsion resistant powder coating along with inbuilt thermal overload protection for saftey against overheating complete all as specified and directed.Make: Havells Cat Part No. FHVVEMTDBB09 or equivalent Crompton/ Bajaj/Usha.Note: Old fan will be deposited in MES Store yard. |
| 54 | Supply & fix exhaust fans AC single Phase 230/240 V of size 450 mm sweep with a robust metal body finished with corrsion resistant powder coating along with inbuilt thermal overload protection for saftey against overheating complete all as specified and directed.Make: Havells/ Crompton/ Bajaj/UshaNote: Old fan will be deposited in MES Store yard. |
| 55 | Supply & Fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC),including taking down existing complete as specified and directed. Make: Crompton/ Orient/ Bajaj/ Havells/ UshaNote: Old fan will be deposited in MES Store yard. |
| 56 | Supply & Fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including taking down existing complete as directed.Make: Havells/Bajaj/Crompton/Orient Electric as approved.Note: Old Geyser will be deposited in MES Store yard. |
| 57 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230V, Single phase 10-60 Amps, accuracy class-I 50HZ, conforming to IS 13779, IP-54, with parameters to show data, time, current reading , load , PF, voltage and KWH including taking down etc complete all as specified and as directed by Engineer-in-Charge. Make- Larsen & Tubro/ Japuria Meters/ Havells/Secure Meters/ Elmeasure/ BENLONote: Old meter will be deposited in MES Store yard. |
| 58 | Material and labour for submain wiring complete with and including 2 runs of 6sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including suitable size of PVC conduit, medium grade of size 25mm dia with accessories such as Tees, Elbows, junction box, reducers etc as required and fixed on walls and one run of 6.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge.Note : Two runs of 6sqmm PVC insulated cable and one run of 6sqmm cable and one run of PVC conduit shall be measured as one unit length.Make of Cable-Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GEMake of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 59 | Material and labour for submain wiring complete with and including 2 runs of10sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including suitable size of PVC conduit, medium grade of size 40mm dia with accessories such as Tees, Elbows, junction box, reducers etc as required and fixed on walls and one run of 10.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge.Note : Two runs of 10sqmm PVC insulated cable and one run of 10qmm cable and one run of PVC conduit shall be measured as one unit length.Make of Cable-Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GEMake of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 60 | Material and labour for submain wiring complete with and including 4 runs of10sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including suitable size of PVC conduit, medium grade of size 50mm dia with accessories such as Tees, Elbows, junction box, reducers etc as required and fixed on walls and 2 runs of 10.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge.Note : Four runs of 10qmm PVC insulated cable and two runs of 10sqmm cable and one run of PVC conduit shall be measured as one unit length.Make of Cable-Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GEMake of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 61 | Material and labour for submain wiring complete with and including 2 runs of 4sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including suitable size of PVC conduit, medium grade of size 25mm dia with accessories such as Tees, Elbows, junction box, reducers etc as required and fixed on walls and one run of 4.0sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly including taking down the existing submain wiring complete all as specified and as directed by Engineer-in-Charge.Note : Two runs of 4sqmm PVC insulated cable and one run of 4sqmm cable and one run of PVC conduit shall be measured as one unit length.Make of Cable-Anchor/ havells/finolex /Polycab/Plaza of ISI mark as approved by GEMake of PVC conduit-Anchor, Modi, Pressfit, Precision, Astral, Panasonic Anchor, Polycab, Presto Plast, Supreme |
| 62 | Material and labour for Earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to and including galvanised earth lead wire 4 mm dia, 7.5m long, by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel with provision of charcoal & common salt packed upto minimum 150 mm all around the earth plate, and protected by 15 mm bore light grade galvanised iron pipe and connected to control board / panel / equipment complete all as shown in electrical plate No.3 of MES schedule Part I with PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, MS angle iron frame of size 50mm x 50mm x 5mm, cast iron cover with locking arrangements, GI 20 mm bore medium grade pipe and CI funnel with wire mesh for watering arrangement including necessary excavaion and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge. |
| 63 | Taking down ceiling fan/exhaust fan/wall mounted fan of any make /type/size/sweep, at site from any height of the building for any defects, servicing complete,repairs /overhauling including replacement of worn out parts/rewinding as required , spare parts and refixing in same position incl. sucessful testing on full load wit blade complete all as specified and directed by Engineer-in-Charge. Note- (i) Capacitor, ball bearing, condenser, bushes, split pin, 'U' clamp with rubber reel, shaft PVC canopy and flexible wire will be measured and paid separately as \\"Supply only\\"(ii) Serviceable spares shall be reused.(iii) Rewinding, if required, will be measured and paid seperately |
| 64 | Material and labour for opening the motor of ceiling fans of sweep 1200mm/1400mm, 230 volts, AC single phase, removing old unserviceable wire, cleaning of slots properly and rewinding of burnt ceiling fan with super enamelled copper winding wire of existing gauge with insulating material, heating, varnishing, grasing, re-assemabling the same after testing on full laod with blade and replacement of worn out minor parts including provision of PVC insulated and PVC sheathed flexible copper wire , three core of size 16/0.20mm of length 750mm complete all as specified and as directed by Engineer-in-Charge. Make-Deen Dayal,finolex,Atlas Note- (i) Capacitor, ball bearing, condenser, bushes, split pin, 'U' clamp with rubber reel, shaft and PVC canopy will be measured and paid separately as \\"Supply only\\"(ii) Serviceable spares shall be reused. |
| 65 | Material and labour for opening the motor of exhaust fans of sweep 250mm, 230 volts,AC single phase, removing old unserviceable wire, cleaning of slots properly and rewinding with super enamelled copper winding wire of existing gauge with insulating material, heating, varnishing, grasing, re-assemabling the same after testing on full laod with blade and replacement of worn out minor parts including provision of PVC insulated and PVC sheathed flexible copper wire , three core of size 16/0.20mm of length 750mm complete all as specified and as directed by Engineer-in-Charge. Make-DeenDayal,finolex,Atlas Note- (i) Capacitor, ball bearing, condenser, bushes, split pin, 'U' clamp with rubber reel, shaft and PVC canopy will be measured and paid separately as \\"Supply only\\"(ii) Serviceable spares shall be reused. |
| 66 | All as per item no. 65 above but of 300mm sweep complete all as specified and directed by Eng-in-charge. |
| 67 | All as per item no. 65 above but of 450mm sweep complete all as specified and directed by Eng-in-charge. |
| 68 | Material and labour for opening the motor of wall mounted fans of sweep 450/600mm, 230 volts,AC single phase, removing old unserviceable wire, cleaning of slots properly and rewinding with super enamelled copper winding wire of existing gauge with insulating material, heating, varnishing, grasing, re-assemabling the same after testing on full laod with blade with replacement of worn out minor parts including provision of PVC insulated and PVC sheathed flexible copper wire , three core of size 16/0.20mm of length 750mm complete all as specified and as directed by Engineer-in-Charge. Make-Deen Dayal, finolex,Atlas Note- (i) Capacitor, ball bearing, condenser, bushes, split pin, 'U' clamp with rubber reel, shaft and PVC canopy will be measured and paid separately as \\"Supply only\\".(ii) Serviceable spares shall be reused. (iii) Contractor has to collect the unserviceable fans from MES complaint cell and after repair ,testing of fans the same shall be deposited in same place . |
| 69 | Supply only following items for ceiling fan, pedestal fan, wall fan and exhaust fan of any sweep,make , model and type complete all as specified and as directed by Engineer-in-Charge. |
| 70 | Fan condenser 2.5 MFD, 230V, AC complete all as specified and as directed by Engineer-in-Charge.Make: Usha, Fentex, Tesla, Epcos, Havells |
| 71 | Fan capacitor 4.0 MFD, 230V, AC complete all as specified and as directed by Engineer-in-Charge.Make: Usha, Fentex, Tesla, Epcos, Havells |
| 72 | Flexible wire 23/0.0076 size, three core, 1100 Volt, twisted, PVC insulated, copper conductor, multistranded, FRLS for connection complete all as specified and as directed by Engineer-in-Charge. Make: Polycab, Havells, Plaza |
| 73 | Supply only MS clamp of suitable size for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge. |
| 74 | Supply only down rod, MS, 15mm dia, heavy duty of size 300mm for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge. |
| 75 | Supply only down rod, MS, 15mm dia, heavy duty of size 450mm for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge. |
| 76 | Top/bottom canopy suitable for ceiling fan of 1200/1400mm sweep |
| 77 | Cutting openings/redressing , through brick walls built in cement mortar for exhaust fan upto 300mm size, cleaning and stacking bricks, removing surplus serviceable bricks, etc.. to store, rubbish outside MD land and making good in cement concrete 1:2:4 type B-0 as required, rendering 10mm thick in CM (1:6) to match with the existing surfaces including grouting of bolts for mounting of exhaust fan complete all as specified and as directed by Engineer-in-Charge. |
| 78 | Material and labour for preparing old surfaces of ceiling fan/exhaust fan/wall mounted fan of any capacity or sweep, by scrapping and removing dust etc and filling cavities with one coat of filler and spray painting with synthetic enamel paint and writing MES Nos in block letters as per existing complete all as specified and as directed by Engineer-in-Charge. |
| 79 | Taking down carefully storage type electric water heater (Geyser) of any capacity, carrying out servicing including replacement of various parts, if necessary, such as different sizes of screws and clamps, base assembly, washers, glands of all types/ valves / heating elements / Thermostat pipes / drain plug / thermal cut-out / safety valve and worn out minor parts to ensure water tightness including re-fixing in the position after testing complete all as specified and as directed by Engineer-in-Charge.Note : Base plate assembly, Heating elements,thermostat pipes,thermal cut out and safety valve will be measured and paid saperately as \\"Supply only\\" |
| 80 | Supply only following items for water heater and geyser of any model and type complete all as specified and as directed by Engineer-in-Charge. |
| 81 | Heating elements of capacity 1.5/2 KW, AC, 230 Volt complete all as specified and as directed by Engineer-in-Charge. |
| 82 | Thermal cut out suitable for 25/50 Litres capacity geyser complete all as specified and as directed by Engineer-in-Charge. |
| 83 | Supply & Fix in repairs Safety valve/high pressure release valve, ISI marked for geyser of capacity 25/50 ltr complete all as specified and as directed by Engineer-in-Charge. |
| 84 | Material and labour for preparing old surfaces of geyser of any type and capacity by scrapping and removing dust etc and spray painting with synthetic enamel paint and writing MES Nos in block letters as per existing complete all as specified and as directed by Engineer-in-Charge. |
| 85 | Supply and fix in repairs PVC heavy duty(breaded) connecting pipe of 15 mm dia and 600 mm long with adaptor complete all as specified and as directed by Engineer-in-Charge. |
| 86 | Supply and fix in repairs PVC heavy duty(breaded) connecting pipe of 15 mm dia and 450 mm long with adaptor complete all as specified and as directed by Engineer-in-Charge. |
| 87 | Supply and fix in repairs Indicator lamp round/rectangular complete all as specified and as directed by Engineer-in-Charge. |
| 88 | Note: Deduct Credit for demolished / dismantled material of Rs. (-) 52,296.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Please Enable Macros to View BoQ information |