| 1 | Taking down chowkhats or frames with shutters n.exc 1.5 sqm each(without taking off shutters from the frame) and all as directed. |
| 2 | Taking down chowkhats or frames with shutters exc 1.5 sqm but n.exc 4.00Sqm each(without taking off shutters from the frame) and all as directed. |
| 3 | System Aluminium Factory made Double Rebate Windows with Grill and MeshProviding and fixing of A2Z Series (A2Z Infra Solutions/Rayners/BWS Windows/ Lilli Windows make) Double rebate windows & ventilators made of High-performance factory-made system Aluminium windows with Akzonobel powder coating of 60-70 microns (Any RAL Colour). Section for Outer frame should be of 91mm x 35mm, Glass shutter frame shall be of 54mm x 30mm, Mesh shutter frame shall be of 54mm x 30mm, 5mm thick Single Glazed beading shall be of 15mm x 18mm. 5mm thick Clear Glass shall be used in all the windows & ventilators. Stainless Steel Wire Mesh shall be used in Wire mesh Shutters. 10mm Sq bar S.S. (304 Grade) Grill/Guard bar with 150mm c/c shall be fixed in between glass & mesh shutter. All frame corners shall be joined/assembled using self-locating corner cleats (No screwing at corners shall be allowed). All Hardware shall be used from a reputed brand, weather silicon shall be used for filling the gap between window opening & window Frame complete in all respect including all taxes. (Makes - A2Z Infra Solutions/Lilli Windows/BWS Windows/Rayners)Note:- Rate shall include for Glass, Wire Mesh & Guard Bras Grill)\\" 2. Rate shall include for neccessary scaffolding work. |
| 4 | Excavation in soft/loose of soil in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out complete all as specified and as directed. |
| 5 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as filling mass concrete etc complete all as specified and directed. |
| 6 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains, side guide wall including all necessary form work complete all as specified and directed. |
| 7 | M&L extra for forming fair finished drain or channel up to 45 cm cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. |
| 8 | M&L for 15 mm thick cement plastering over brick wall in cement mortar 1:4 finished even and smooth complete all as specified. |
| 9 | M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in coping, etc including all necessary form work complete all as specified and directed. |
| 10 | M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 all as specified. complete as directed. |
| 11 | Taking down cement or cement lime plaster on brick or stone walls/ etc including raking out joints, hacking for key, scrubing down with water complete all as specified and directed. |
| 12 | M&L for preparing New plasteres surfaces Wall and applying of Birla/JK white wall care putty approx 2 mm thick on Wall as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of oil emulsion distemper over a coat of primer paint on Wall complete all as specified and directed.Note:- Painting should be done by automatic airless spray technology with max working pressure. |
| 13 | M&L preparation of new plastered surfaces and applying two coats of cement base paint over a coat of cement primer on external surfaces of walls complete all as specified and directed.Note:- 1. Work shall execute up to 15mtr Height2. Rate shall include for neccessary scaffolding work.3. Painting should be done by autometic airless spray technology with max working pressure. |
| 14 | M&L for rendering 15mm thick on brick or brick work or concrete in cement mortar 1:4 external surfaces of wall finished even and fair without using extra cement complete all as specified and directed.Note:- 1. Work shall execute up to 15mtr Height2. Rate shall include for neccessary scaffolding work. |
| 15 | M&L for rendering 10mm thick on brick or brick work or concrete in cement mortar 1:6 inernal surfaces of wall finished even and fair without using extra cement complete all as specified and directed. |
| 16 | M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars,window-cills, cooking platform and like in cement morter (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete including 15 mm thick bedding layer in cement mortar 1:6 as in Window Cills/Stair Case complete all as specified and directed. Please Enable Macros to View BoQ information |