| 1 | Dismantling posts (embeded in Concrete, brick work, masonry, etc.) or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified & directed by Engr-In-Charge. |
| 2 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation & mass concrete etc complete all as specified & directed by Engr-In-Charge. |
| 3 | Dismantling fencing wire mesh, any type complete all as specified & directed by Engr-In-Charge. |
| 4 | S & F angle iron posts and struts in fencing including cutting tops of shape as directed, drilling holes, notching for wire, etc.,flat iron fillets and round bars with hooks at ends (for securing wire mesh etc.) includindall necessary drilling, bolting or riveting, etc, and similar work confirming to Fe -290 Gde E-165 complete all as specified & directed by Engr-In-Charge. |
| 5 | Fixing only angle iron posts and struts in fencing as retrieved complete all as specified & directed by Engr-In-Charge. |
| 6 | S&F 11 to 15 mm Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified & directed by Engr-In-Charge. |
| 7 | S&F mild steel round bars 10mm dia cut to length, bent to shape as required and fixed in fencing confirming to Fe 410-Wor Fe 290 complete all as specified & directed by Engr-In-Charge. |
| 8 | Supply only MS galvanised chain link wire mesh 100mm x 100 mm size of mesh as in fencing with 3.15mm dia galvanised steel wire complete all as specified & directed by Engr-In-Charge. |
| 9 | Fixing only chain link fencing including line wires, any mesh & size and type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed by Engineer-in-Charge. Note :- Chain link fencing shall be measured and paid for separately under respective item of BOQ |
| 10 | S&F in repairs galvanised 2 strand steel barbed wire 2.24mm, dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire staples or steel pins (Each line wire to be measured) complete all as specified & directed by Engr-In-Charge. |
| 11 | M&L mild steel framed work of Fe-290 (Gde E-165) as in doors or gates of angle and other section with gusset plates, rails, braces, etc., complete, grills/guard bars shouldered with steel windows/ventilators frames, Cooler stand, ladder, wire mesh etc complete all as specified & directed by Engr-In-Charge. |
| 12 | M & L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic paint over one coat of red oxide primer complete all as specified & directed by Engr-In-Charge. |
| 13 | M & L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of black bituminous paint complete all as specified & directed by Engr-In-Charge. |
| 14 | M&L for preparation of old steel painted surfaces including as knotting, stopping, Burning off or removing, scraping etc,and then applying one coat of synthetic enamel paint (ordinary tint) on steel surfaces over 10cm width or girth complete all as specified and directed by Engineer - in - Charge. |
| 15 | M&L for preparation of old steel painted surfaces including as knotting, stopping, Burning off or removing, scraping etc,and then applying two coats of black bituminous paint over 10cm width or girth complete all as specified and directed by Engineer - in - Charge. |
| 16 | Demollition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing the debris and rubbish to a distance nexc 100 mtr complete all as specified & directed by Engr-In-Charge. |
| 17 | M&L PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundation, sub base filling and mass concrete complete all as specified & directed by Engr-In-Charge. |
| 18 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified & directed by Engr-In-Charge. |
| 19 | M&L Hard core of broken brick aggregate gauge not exc. 63mm deposited spread and leveled in layers not exc. 15cm thick watered and rammed to a true surface complete all as specified & directed by Engr-In-Charge. |
| 20 | M&L machine pressed precast concrete interlocking paver block with grey cement and pigment (coloured tiles) of any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified & directed by Engr-In-Charge. |
| 21 | M&L machine pressed precast concrete interlocking paver block with grey cement and pigment (coloured tiles) of any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade complete all as specified & directed by Engr-In-Charge. |
| 22 | Dismanteling of depressed precast concrete interlocking paver block of any shape and size and refixing same after making good with PCC/ hard core complete all as specified & directed by Engr-In-Charge.Note: PCC/ Hardcore shall be paid seperately. |
| 23 | M&L coloured Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complete all as specified & directed by Engr-In-Charge. |
| 24 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including necessary excavation in fdn, removal excavated soil and making drainage opening wherever required complete all as specified and as directed by Engr-In-Charge. |
| 25 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified & directed by Engr-In-Charge. |
| 26 | M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified & directed by Engr-In-Charge. |
| 27 | All as per item No 26 above but except bricks complete all as specified & directed by Engr-In-Charge. |
| 28 | M&L for Fly ash Brick work with old size sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified & directed by Engr-In-Charge. |
| 29 | M&L for Brickwork with fly ash bricks or brick tiles in brickon- edge walls (less than ½brick thick),built inbuilt in cement mortar (1:4) complete all as specified & directed by Engr-In-Charge. |
| 30 | M&L for Cement concrete 1:2:4 type B2 (using 20mm graded aggregate) as in surface channels and drains complete all as specified & directed by Engr-In-Charge. |
| 31 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified & directed by Engr-In-Charge. |
| 32 | Taking down cement plaster from brick walls including wall tiles / terrazzo / kota stone etc. any type of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed by Engr-in-Charge |
| 33 | M&L for Raking out joints/ pointing to brick work to bricks on edge in floors, surface channels, roofs, etc in cement lime mortar complete all as specified & directed by Engr-In-Charge. |
| 34 | M&L for Rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr -in - charge. |
| 35 | M&L for Providing precast cement concrete 1:3:6 (12.5 mm graded aggregate) louvres and jallies, 25mm thick (measured solid) Set in CM 1:4 all as specified and directed by Eng-in Charge |
| 36 | M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed by Engr -in - charge. |
| 37 | M&L for preparation of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of cement base paint complete all as specified & directed by Engr-In-Charge.Note :- Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I |
| 38 | M&L for PCC 1:3:6 type C1 using (20mm graded aggregate) as in coping, kneelers, apex stones, bed plates, kerbs etc including necessary formwork complete all as specified and directed by Engr-in-Charge |
| 39 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge. |
| 40 | M&L for re-inforced cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed by Engr-In-Charge. |
| 41 | M&L Formwork (flat, rough finished surfaces of concrete) to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified & directed by Engr-In-Charge. |
| 42 | M & L for 100mm thick plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in floors finished fair and even for laying tiles complete all as specified and directed by Engineer-in-Charge. |
| 43 | M & L for 75mm thick plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base finished even and fair complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in soft/loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified & directed by Engr-In-Charge. |
| 45 | Dismantling fencing wire mesh and re-fixing in the same location or other location to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified & directed by Engr-In-Charge. |
| 46 | S & F in repair iron strip for supporting chain link fencing complete all as specified & directed by Engr-ln-Charge. |
| 47 | M&L for punched tape concertina coil, 600mm diameter ,06 metre openabte length,having 50 Nos round per 06 metre, tied with angle iron post with necessary bolts.concertina coil of core wire diameter 2.5mm,blade thickness 0.5mm,blade length 12mm,width of blade 15mm and spacing of blade 26mm complete all as specified & directed by Engr-In-Charge. Note: The weight of concertina coil shall be ascertained by BOO as ordered by GE and payment shall be made accordingly. |
| 48 | M&L PCC 1:2:4 type B1 (using 20mm graded aggregate ) as in coping including weathering, slightly rounded or chamfered angles and throating, complete all as specified & directed by Engr-In-Charge. |
| 49 | M&L for preparation new concrete/bricks surface of any description over 10cm girth or width, not otherwise described and applying two coat of synthetic enamel paint over primer complete all as specified and directed by Engr-In-Charge. |
| 50 | M&L for 50 mm thick Cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) as in hard standing , path etc including Use and waste of form work/screed strips and to divide the area in panels and finishing the surface even and fair complete all as specified & directed by Engr-In-Charge. |
| 51 | Rendering 15mm thick in cement mortar 1:6 on any face of brick walls or concrete surfaces, finished even and fair without using extra cement complete all as specified & directed by Engr-In-Charge. |
| 52 | M&L for Providing precast cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) in cover slabs for man holes, window or door cills, , drain cover slab etc. with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:6 complete all as specified & directed by Engr-In-Charge.Note:- Necessary reinforcement will be measured and paid separetly. |
| 53 | M & L for Mild steel bars of TMT 10mm dia and over, cut to length bent to Shape required incl cranking, bending spirally for hooping for columns, tie bars/dowel bars in longitudinal joints/transverse joints etc, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engr-In-Charge. |
| 54 | M & L for RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in drain,Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified & directed by Engr-In-Charge. |
| 55 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work like drains including attached pillasters, buttresses etc.; vertical or to batterfor flat surfaces complete all as specified & directed by Engr-In-Charge. |
| 56 | S&F in Repair Reinforced concrete pipes, class NP2, 300 mm Dia laid and jointed complete with collars complete all as specified & directed by Engr-In-Charge. |
| 57 | M & L for cement concrete 1:3:6 type C-2 as in bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in for 300 mm dia pipe.complete all as specified and directed by Engineer - in - Charge. |
| 58 | Demolition cement concrete (reinforced) in ground floor and pavinng not exc 15 cm thickness (below or above G.L) complete all as specified and directed. Please Enable Macros to View BoQ information |