| Sl. No. | Item Description |
| 1 | GST rate/ amount, SAC & Total amount incl. GST |
| 2 | PE PIPELINE |
| 3 | Pipe laying on any unprepared surface (Katcha surface) / normal surface / hard surface (all types of hard rock) using open cut / moling/HDD - (without casing) methodology |
| 4 | Receipt, loading, unloading, storing, reloading, transportation, uncoiling, stringing, and laying of PE100, SDR11/17.6 line pipes of all sizes, including proper stacking, identification, and supply of accessories of all sizes and thickness like PE bends, saddles, couplers, end caps, tees (equal/reducing), reducers, CS/GI to PE fittings (i.e., transition fittings of sizes 20 mm to 32 mm), warning mat (300 mm width as per attached technical specification and QAP), etc. Handling, stringing/uncoiling, aligning of the PE line pipe on the pipeline right-of-use/route, laying/installation of PE line pipe along with required accessories as mentioned above as per specification wherever required depending on site conditions, including execution of all associated works; storage of material in contractor's store in a safe manner, prefabrication/fabrication, access for prefabrication/fabrication area, all procured/supplied materials for construction, consumables, equipment, labor, and other inputs. In the case of free issue items, the scope also includes receiving and loading from owner’s designated store within GA, transportation, unloading, and stacking of free issue items at contractor's store. |
| 5 | Carrying out all temporary, ancillary, and auxiliary works required to make the laid PE pipeline system complete and ready for commissioning as per drawings, specifications, and as per the direction of Engineer-In-Charge (EIC). |
| 6 | Specifications, scope of work indicated in PJS and other provisions of the contract document and instructions of Engineer-in-charge, including but not limited to carrying out the following works |
| 7 | Surveying of route and detours required at the time of execution including marking the same in topographical sheet, preparation of construction drawings showing survey details, and submit same to Owner for review/approval. |
| 8 | Carrying out preliminary & final survey activities for crossings encountered in the pipeline route and preparation of drawings with crossing methodology, etc., wherever required, and submission to Owner/Engineer-in-charge for review/approval. |
| 9 | Preparation and getting approval of execution schedules, execution procedures, drawings/sketches wherever required from Owner/Engineer-in-charge and/or from concerned authority, making trial pits to determine the underground utilities/services, etc., restoration of the abandoned trial pits to original condition to the entire satisfaction of Owner/Engineer-in-charge and/or concerned authority. |
| 10 | Stacking and installation of construction markers, clearing/grading of work area, fencing, grubbing, cutting of trees, etc. within work area and fulfilling all the requirements of various statutory/environment authorities to their entire satisfaction. |
| 11 | Barricading the work area as per local authorities' guidelines/norms and to the entire satisfaction of Owner/Engineer-in-charge, installation of safety signs to the satisfaction of Owner/Engineer-in-charge and/or as per local authorities' guidelines/norms. |
| 12 | Barricading the pipeline construction area prior to execution of the works as per standard drawing enclosed with the tender document and to the entire satisfaction of the owner/engineer-in-charge. |
| 13 | Laying using open trench without casing/Moiling/HDD without casing includes survey of underground utilities (through trial pits), execution of work as per specification including trenching to all depths by excavation in all types of soils including soft/rocky strata and different types of pavement/footpath/roads, etc., including rock breaking, chiseling or otherwise cutting, as required and storing excavated soil and reusable materials at designated areas as directed by Engineer in charge and to a width to accommodate the pipeline as per the relevant standard specification. The minimum depth of the top of the pipeline shall be 1.0 m measured from the top of the pipeline to the top of the undisturbed surface of the soil or as per Specification/OISD-226 & PNGRB latest guidelines, whichever is higher. Dewatering of trenches/pits if required as per site conditions. Repairing of all damaged utilities, if any, and payment of any compensation (if claimed by owner/other utility agencies). |
| 14 | Uncoiling / stringing & aligning of PE pipes, clamping, jointing of the pipe ends/fittings/valves by qualified personnel using approved electro-fusion techniques as per specification. |
| 15 | Installation/lowering the pipeline in trench to required depth as per PJS, Technical Specification & drawings, supply & placement of HOPE Yellow color warning mat (300 mm width as per attached Technical specification and QAP) over the pipeline along the complete route as per standard drawings, data sheets & technical specifications, padding around pipeline including supply of suitable padding material duly approved by EIC, backfilling to its original condition with excavated earth/borrowed select soil/sand duly approved by EIC & its compaction & crowning. At certain specific areas of ROU, trench shall be backfilled & compacted and shall be made ready for motorable. All tiles/slabs/curb stones etc. removed during excavation shall be placed packed properly and no separate payment shall be admissible against this activity. Restoration shall be carried as per separate SOR item mentioned elsewhere in the SOR or to be done by Owner/concerned authorities. |
| 16 | The scope of work against this item also includes Electro-fusion jointing of valves, fittings, saddle, etc., wherever required and as directed by the Engineer in-charge. |
| 17 | The scope of work against laying of 20/32 mm pipe also includes works like making of PCC pedestal of grade (1:2.4) and size (8\\" depth x 6\\" length x 4\\" width), which may slightly vary in dimension and volumetric quantities of PCC and may increase up to 25% more as per site requirement, supply and installation of GI Sleeve (Heavy C-Class as per IS-1239), supply & filling of sand, and installation of TF (along with supply). |
| 18 | Flushing, Pneumatic testing, purging with nitrogen, and commissioning as per specification and approved procedures, providing all tools and tackles, nitrogen, instruments, manpower, and other related accessories, and as per the instructions of the Engineer-in-Charge. |
| 19 | Final clean-up of right-of-way or area disturbed by contractor during their construction activities for laying of pipeline works and disposal of debris and surplus material to designated disposal areas within GA, and backfilling of trench and compaction of the same to the satisfaction of Owner and/or as deemed by Engineer-in-charge. |
| 20 | Maintaining the worthiness of the complete pipeline system along with associated facilities until handover to the OWNER/ETC and to carry out rectification/replacement works for any defects or failures reported by OWNER during defect liability period. |
| 21 | Handing over the completed works to Owner for their operation/use, reconciliation of materials area-wise, and obtaining \\"no objection certificate\\" from Owner/PMC. |
| 22 | Preparation and submission of daily progress reports, laying graphs/PE line cards on a daily basis, and getting them reviewed/inspected by the Owner/Owner representative/PMC. |
| 23 | On completion of gas charging of pipelines. Preparation and submission of As-built drawings, crossings details, termination, utility graphs, and deviation statements. |
| 24 | In case the minimum required depth is not possible due to site conditions, necessary mitigation measures shall be required to be taken by the contractor in consultation with EIC as per PNGRB Guidelines. No additional payment shall be admissible against the same. |
| 25 | Submission of all documents required for contract closure as mentioned in the contract document, as per guidelines of the Owner/PMC. |
| 26 | Any other activities not mentioned/covered explicitly above, but otherwise required for satisfactory completion/operation/safety/statutory/maintenance of the works shall also be covered under the scope of work and have to be completed by the Contractor within the specified time schedule at no extra cost to Owner. All the work shall be executed in accordance with the provisions of the contract and/or latest guidelines of the statutory authority, whichever is stringent. |
| 27 | 20/32 mm PE 100 pipe Service line laying upto 6 Mtr. length -(On Charged/ pressurised line)/Online GC (Applicable For already charged line/pressurized) |
| 28 | 20/32 mm PE 100 pipe |
| 29 | 1) The lengths of pipelines are tentative. 2) For restoration of asphalt / concrete roads, the item for construction of asphalt top / concrete top / red stone / paver shall be paid separately as per the rates quoted for the same elsewhere in the SOR. 3) The measurement will be made from tapping saddle on existing PE pipe of various sizes of existing network to Transition Fitting (PE to GI). The tapping saddle, Transition Fittings and other fittings shall be included in the measurement. 4) The measurement will be made from tapping saddle on existing PE pipe of various sizes of existing network to Transition Fitting (PE to GI). The tapping saddle, Transition Fittings and other fittings shall be included in the measurement. 5) Payment against SOR item no. A00102 will be applicable only in case of Ground Connectivity with Installation of TF, Pedestal and in case of ONLINE GROUND CONNECTIVITY from a existing charged/pressurised line. In case Ground Connectivity/Service Line is laid by taking tapping from Contractors's own laid line then payment shall be made as per SOR item no. A001036) In case quantity increases beyond 6 meter (against SOR item no A00102) payment towards additional length beyond 6 Mtr shall be paid as per SOR item no. A00103 |
| 30 | 32 mm PE 100 pipe by Open Cut Method (excluding Rocky strata) |
| 31 | 32 mm PE 100 pipe by Moling/HDD Method (excluding Rocky strata) |
| 32 | 32 mm PE 100 Pipeline Laying Through Open cut(without casing) for all type of Rocky strata |
| 33 | 32 mm PE 100 Pipeline Laying Through Moiling(without casing)for all type of Rocky strata |
| 34 | 32 mm PE 100 Pipeline Laying Through HDD (without casing) for all type of Rocky strata |
| 35 | 63 mm PE 100 pipe by Open Cut Method (excluding Rocky strata) |
| 36 | 63 mm PE 100 pipe by Moling/HDD Method (excluding Rocky strata) |
| 37 | 63 mm PE 100 Pipeline Laying Through Open cut(without casing) for all type of Rocky strata |
| 38 | 63 mm PE 100 Pipeline Laying Through Moling/HDD (without casing) for all type of Rocky strata |
| 39 | PE pipe laying of sizes 20 mm/32 mm inside private property i.e., multi-story buildings/apartments with no movement of heavy vehicles, surrounded by boundary wall where pipe top cover could not be achieved 600 mm. |
| 40 | Minimum pipe top cover of 375 mm is required and the line pressure shall not exceed 110 mbar. |
| 41 | Necessary mitigation measures such as RCC slab (150mm thick and 300mm width) at the top, and the RCC slab of the roof of the basement shall be treated as the bottom. There may be sand filling across three sides of the line pipe of 100mm each, which shall be required to be taken by the contractor in consultation with EIC as per the latest PNGRB Guidelines. No additional payment shall be admissible against the same. |
| 42 | Receipt, loading, unloading, storing, reloading, transportation, unloading, uncoiling, stringing, and laying of PE100, SDR11/17.6 line pipes of all sizes, including proper stacking, identification, and supply of accessories of all sizes and thicknesses like PE bends, saddle, couplers, endcaps, tee (equal/reducing), reducer, CS/GI to PE fittings (i.e. Transition Fittings of sizes 20 mm to 32 mm), Warning Mat (300 mm width as per attached Technical specification and QAP), etc. Handling, stringing, uncoiling, aligning of the PE line pipe on the pipeline Right-of-Use/route, laying/installation of PE line pipe along with required accessories as mentioned above as per specification whatever required depending on site condition including execution of all works. Storage of material in contractor’s store, fabrication, access for construction, procurement, and supply of all materials, consumables, equipments, labor, and other inputs. In the case of free issue items, the scope also includes receiving and loading from Owner's designated store, transportation, unloading, and stacking of free issue items at Contractor's store. |
| 43 | Carrying out all temporary, ancillary, auxiliary works required to make the PE pipeline ready for commissioning as per drawing, |
| 44 | Surveying of route and detours required at the time of execution, preparation of construction drawings showing survey details, and submit the same to Owner for review and approval. |
| 45 | Preparation and getting approval of schedules, execution procedures, drawings/sketches wherever required, making trial pits to determine the underground utilities/services etc., restoration of the abandoned trial pits to original condition. |
| 46 | Barricading the pipeline construction area prior to execution of the works as per std drawing enclosed with tender document and to the entire satisfaction of owner/engineer-in-charge. |
| 47 | Laying using open trench without casing includes survey of underground utilities (through trial pits), execution of work as per specification including trenching to all depths by excavation in all types of soils including soft/rocky strata and different types of pavement/footpath/roads, etc., including rock breaking, chiselling, or otherwise cutting as required, and storing excavated soil, reusable materials at designated area as directed by Engineer In charge and to a width to accommodate the pipeline as per the relevant standard/specification, etc. [The minimum depth of the top of the pipeline shall be 1.0 m measured from top of the pipeline to the top of undisturbed surface of the soil or as per Specification/OISD-226 B PNGRB latest guidelines whichever is higher]. Dewatering of trenches/pits if required as per site condition, Repairing of all damaged utilities if any, and payment of any compensation (if claimed by owner/other utility agencies). |
| 48 | Unrolling/stringing & aligning of PE pipes, clamping, jointing of the pipe ends/fittings/valves by qualified personnel using approved electro-fusion techniques as per specification. |
| 49 | Installation/lowering the pipeline in trench to required depth, supply & placement of HDPE Yellow color warning mat (300 mm width as per attached Technical specification and QAP) over the pipeline along the complete route as per standard drawing and backfilling to its original condition with excavated earth/borrowed select soil/sand duly approved by EIC & its compaction & crowning. At certain specific areas of ROU, trench shall be backfilled & compacted and shall be made ready for motorable. All tiles/slabs/curb stones etc. removed during excavation shall be placed properly and no separate payment shall be admissible against this activity. Restoration shall be carried out as per separate SOR Item mentioned elsewhere in the SOR or to be done by Owner/concerned authorities. |
| 50 | The scope of work against laying of 20 mm/32 mm pipe also includes works like making of PCC pedestal of grade (1:2:4) and size (300mm(L)X200mm(W) XHeight (H)), (H>=300mm & will be as per site condition), supply and installation of GI Sleeve (Heavy (C-Class) as per IS-1239), filling of sand, and installation of TF (along with supply). |
| 51 | Pneumatic testing, purging with nitrogen, and commissioning as per specification and approved procedures providing all tools and tackles, nitrogen instruments, manpower, and other related accessories and as per the instructions of the Engineer-in-charge. |
| 52 | Final clean-up of right-of-use or area disturbed by contractor during their construction activities for laying of pipeline works and disposal of debris and surplus material to designated disposal areas, and backfilling of trench and compaction of the same as per satisfaction of Owner and/or as directed by Engineer-In-charge. |
| 53 | Maintaining the completed pipelines and installations for any defects or failures during the defect liability period. |
| 54 | Handing over the completed works to Owner for their operation/use, reconciliation of material area-wise, and obtaining \\"no objection certificate\\" from Owner/Consultant. |
| 55 | On completion of gas charging of pipelines, Preparation and submission of As-built drawings, crossings details, termination, utility graphs, and deviation statements. |
| 56 | Any other activities not mentioned/covered explicitly above, but otherwise required for satisfactory completion/operation/safety/statutory maintenance of the works shall also be covered under the scope of work and has to be completed by the Contractor within specified schedule at no extra cost to Owner. All the work shall be executed in accordance with the provision of the contract. |
| 57 | 20 mm PE 100 pipe |
| 58 | 32 mm PE 100 pipe |
| 59 | Civil Work/Cutting/Breaking and Restoration |
| 60 | Restoration of the roads, pavements, channels, footpaths, tiles, slabs, etc. to original condition including supply of the approved quality material required, as per local authorities' norms, obtaining NOC from landowners/third-party inspection agencies/Consultant designated by GAIL and to the satisfaction of Engineer-In-charge. |
| 61 | AsphaltingRestoration of bitumen Asphalt road after laying of pipe line as per the specifications and instruction of Engineer-In-Charge. Restoration of roads shall be done as per requirement of RMC/MCD/PWD/LOCAL ASSOCIATIONS & BODIES, BUILDER, RWA and to get NOC from the concerned authorities. Restoration of the asphalt road cut portion for pipeline trench width shall be carried out by filling the bottom layer with good earth/Soil filling followed by 225mm thk. GSB & 250mm thk. WMM with top bituminous layers comprising of 50mm thk. DBM & 40mm thk. BC matching with the existing road top level. This item also includes disposal of surplus soil /debris with all lift & leads, cutting of Top layer of asphalt road by mechanized saw/cutters for maintaining straight line. |
| 62 | Breaking/Cutting of Cement Concrete - Making provision for PE Pipe laying as per site requirement and as per instruction of EIC. |
| 63 | Cement Concrete Restoration as per scope of work (Excluding Breaking/Cutting). |
| 64 | Breaking/Cutting of RCC Core - Making provision for PE Pipe laying as per site requirement and as per instruction of EIC. |
| 65 | RCC restoration as per scope of work (Excluding Breaking/Cutting). |
| 66 | Tiles/ Paver/ Blocks/ Curb Stones,Red sand stone |
| 67 | Brick Soling/ Stone Soling, etc |
| 68 | Providing, hoisting, and placing of 75 mm thick precast reinforced cement concrete slab of M-20 grade over the pipeline as mechanical protection including the cost of required centering, shuttering, reinforcement complete as per tender drawing and direction of the EIC. Note: Size (Length x Width) of the precast slab will be decided as per site condition and as per instruction of EIC. Precast slab will be placed in multiple numbers and various locations as per site condition and as per instruction of EIC. |
| 69 | Valve pit chamber (Brick Masonry)Constructing valve pit chamber in brick masonry with cement mortar 1:4 (1 cement: 4 coarse sand) over 150 mm thick RCC Foundation along with 75 mm thick leveling course in 1:4:8 mix including 16 mm thick plastering with cement mortar 1:3 (1 cement: 3 coarse sand) and PCC pedestal for Valve support (if required) complete as per specification, drawings, and direction of EIC. Valve Pit Chamber shall be covered with 150 mm thick RCC top slab of M-25 grade with manhole cover (medium duty) along with frame as per IS 1726. Rate to include the cost of all labor, tools, tackles, equipment, hire charges, supply of all materials such as minimum 45 grade cement, reinforcement, CI manhole cover, PVC coated rungs, inserts including excavation and backfilling, masonry works, plastering, etc., with all bye works and sundry works. |
| 70 | Type I : Inside size 1500 mm x 1000 mm and upto 1500 mm deep |
| 71 | Type II : lnside size 1500 mm x 1000 mm and greater than 1500 mm deep |
| 72 | Type I : Inside size 1000 mm x 1000 mm |
| 73 | Valve Pit Chamber (RCC)Constructing valve pit chamber in RCC of grade M-25 over 75 mm thick leveling course in 1:4:8 mix including 16 mm thick plastering with cement mortar 1:3 (1 cement : 5 coarse sand) and PCC pedestal for Valve support (if required) complete as per specification, drawings, and direction of EIC. Valve Pit Chamber shall be covered with 150 mm thick RCC top slab of M-25 grade with manhole cover (medium duty) along with frame as per IS 1726. Rate to include cost of all labor, tools, tackles, equipment, hire charges, supply of all materials such as minimum 45 grade cement, reinforcement, CI manhole cover, PVC coated rungs, inserts including excavation and backfilling, masonry works, plastering, etc., with all bye works and sundry works. |
| 74 | Tvpe I : Inside size 1500 mm x 1000 mm and upto 1500 mm deep |
| 75 | Type II : Insida size 1500 mm x 1000 mm and greater than 1500 mm deep |
| 76 | Type I : Inside size 1000 mm x 1000 mm |
| 77 | Installation of valve in pit including supply of valves: Supply of isolation valves (as per data sheet) and installation of valves in the valve pits as per typical drawing and specification enclosed and instructions of Engineer-in-charge. Payment of valve pits shall be paid separately as per SOR. |
| 78 | PE Valve 32 mm dia |
| 79 | Pipe Laying in any unprepared surface (Katcha surface) / Normal Surface / Hard surface (all types of hard rock) using open cut with casing Moling with Casing methodology. |
| 80 | Laying of all PE pipe (PE 100 SDR11), including supply of HDPE casing pipe, Saddle, Couplers, End caps, etc. (As per particular job specification). |
| 81 | Survey of underground utilities, execution of the work as per specification, including excavation of pits, moling with the hole size not exceeding 20% of the pipe dia, jointing and insertion of carrier pipe with casing, testing & commissioning, and restoration of the pits to original condition, submission of As-Built Graphs as per specifications and the instructions of Engineer-In-Charge. |
| 82 | 20 mm PE 100 pipe (in 50 mm dia. HDPE Casing Pipe) by open cut Method with casing |
| 83 | 20 mm PE 100 pipe (in 50 mm dla. HDPE Casing Pipe ) by Moiling Method with casing |
| 84 | 32 mm PE 100 pipe (in 75 mm dia. HDPE Casing Pipe )by open cut Method wtth casing |
| 85 | 32 mm PE 100 plpa {in 75 mm dia. HDPE Casing Pipe )by Moling Method with casing |
| 86 | Supply of GI/concrete Sleeves (wherever required as a special case as per instructions of the Engineer-in-charge). |
| 87 | Supply, installation of sleeve, insertion of pipe, sealing the annulus area, firm fixing of sleeves with concrete mix. Breaking through any obstructions and their subsequent restoration, as per specifications and instructions of the Engineer-in-charge. |
| 88 | GI Sleeves /Concrete Sleeves |
| 89 | 2 1/2\\" NB, 1' Length |
| 90 | 4\\" NB, 1' Length |
| 91 | 2 1/2\\" NB, 3' Length |
| 92 | 4\\" NB 3 Length |
| 93 | MS Enamel Coated |
| 94 | 4\\" NB, 3' Length |
| 95 | Concrete Sleeve (NPS 2 Class) |
| 96 | 4\\" NB, 3' Length |
| 97 | 6\\" NB, 3' Length |
| 98 | Note: The decision regarding the use of types of sleeves to be used at various locations shall be made by the Engineer-In-Charge (EIC) / Owner. |
| 99 | Fabrication & Installation of Markers |
| 100 | RCC Route Markers |
| 101 | Supply, fabrication, and installation of RCC route markers including application of approved color and quality of primer and paint as per the standard drawing, along the route including all associated civil works such as excavation and construction in all types of soils, construction of pedestals, and grouting with concrete. These works shall be carried out as per installation methodology approved by EIC based on site requirements. |
| 102 | Steel Pole Markers with Foundation |
| 103 | Supply, fabrication, and installation of Steel Pole markers, including application of approved color and quality of primer and paint as per the standard drawings, along with all associated civil works such as excavation and construction in all types of soils, construction of pedestals, and grouting with concrete, cleaning, stench letter cutting of lettering, numbers, direction, etc. These works shall be carried out as per installation methodology approved by EIC based on site requirements. |
| 104 | Warning Plate Markers |
| 105 | Supply, fabrication, and installation of plate markers including application of approved color and quality of primer and paint, stencil letter cutting of lettering, numbers, direction, etc. as per the standard drawings to be installed near the regulator. These works shall be carried out as per installation methodology approved by EIC based on site requirements. |
| 106 | Paver Block Tiles Markers |
| 107 | Supply, fabrication, and installation of Paver Block Tiles markers of standard size as per industry practice along the route on Paver Block/Thee on foot Path/As per the Instruction of EIG including application of approved color and quality of primer and paint, stencil letter cutting of lettering, numbers, direction, etc. Carrying out all associated works for fixing / grouting / anchoring the marker with the surface. These works shall be carried out as per installation methodology approved by EIC based on site requirement. |
| 108 | Crossing of Sewage Drains/Nala alongside independent houses where drains/Nalas are being encountered adjacent to houses. |
| 109 | The scope of work includes supply of medium-duty GI casing pipes of 2.5 inches, along with padding with sandstone and civil works associated with the construction of cover slab as per standard drawing in the tender. |
| 110 | PNG Connection to Domestic/Commercial/Industrial Consumers |
| 111 | Installation of Carbon Steel (CS)/GI Service Pipe |
| 112 | Supply/Receipt, Loading, unloading, storing, reloading, transportation, unloading at work site, and laying of either Owner-supplied Powder-coated GI pipes or Contractor-supplied Powder-coated GI pipes & carbon steel pipes of all sizes & thicknesses, including supply of all associated compatible accessories of all sizes & thicknesses like Elbows, Tees, unions, sockets, reducers, GA plugs, sleeves, etc. Installation of GA line (along with installation of required accessories as mentioned above) of all sizes & thicknesses, including fabrication with supply of all materials, consumables, labor, and other incidental works. The scope of work also includes installation of Regulators (4/6 bar to 100/21 mbar and/or 100 mbar to 21 mbar) which shall be provided as free issue items, Installation of all sizes of isolation Valves (which are to be procured & supplied by contractor mentioned elsewhere as separate items in the SOR). Carrying out all temporary, ancillary, auxiliary works required to make the GI line complete and ready for commissioning as per drawings specifications. Handling, aligning, fabrication & installation of the GA Pipes in the work area along with required associated compatible accessories as mentioned above as per site condition and as per instruction of EIC. Execution of all associated works; Supply of all materials, consumables, equipment, labor, and other inputs; Storage of material in the contractor’s store in a safe manner, pre-fabrication, access for construction/fabrication work area. In the case of free-issue items, the scope also includes receiving and loading from Owner's designated store within GA, transportation, unloading, and stacking of free-issue items at the Contractor's store in a safe condition. |
| 113 | Scope of work indicated in PJS and other provisions of Contract document and instructions of Engineer-In-charge, including but not limited to carrying out the following works |
| 114 | Preparation and getting approval of execution schedules, execution procedures, drawings/sketches from Owner/Engineer-in-charge and/or from concerned authority. |
| 115 | Finalization of optimum route with consent of customer, from transition fitting to cooking oven/appliance. |
| 116 | Making temporary but stable platforms/scaffolding/rope ladders and all other safety measures including safety belts wherever required, |
| 117 | Installation of GI pipes, fittings, including NPT threading, painting as specified. |
| 118 | Drilling of holes through walls (brick, RCC), granite, marble, tiles, cutting with proper heavy-duty hammer drill machine tools and tackles, using proper sealant/grout material and colors to match the original, replacement of damages during drilling, restoring the area to its original condition. |
| 119 | In case of multistory buildings where RCC slab/visor/sunshade/chhata restricts riser installation, then separate payment for cement concrete/RCC core-cutting with heavy-duty drill machine and their restoration shall be paid under SOR items B00201 TO B00204 and as per the instruction and direction of EIC. |
| 120 | Supply and fixing of approved clamps, dowel plugs with screws, grout material, suitable thread sealant (i.e., Teflon Tape/Loctite), drilling of holes through tiles/wood/marble/granite, etc., jointing of PE to aboveground service GI pipes, flushing, pneumatic testing, purging with nitrogen (including supply of nitrogen as inert gas by the contractor), and commissioning or making ready for commissioning of the complete system as per specification and as per instructions of EIC. |
| 121 | Touch-up painting/painting of outer surface of GI pipe of all sizes along with fittings after proper surface finish by one coat of approved primer paint and two coats of approved synthetic enamel paint complete as per specification and direction of EIC. Restoring the wall surface to original condition to the entire satisfaction of EIC and obtaining NOC from end user/consumer/concerned authorities/authorized competent person of the society. |
| 122 | All above activities to be carried out as per specification to the complete satisfaction of consumer & as desired by Engineer-in-charge. |
| 123 | Handing over the completed works to GAIL for operation/ use, reconciliation of material area wise and obtaining \\"no objection certificate\\" from GAIL/GAIL Representative at Site/ CPMC. |
| 124 | Any other activity not mentioned/covered, explicitly above, but otherwise required for satisfactory completion/safety/statutory/maintenance of works shall also be covered under the scope of work and has to be completed by the contractor within the specified schedule time. |
| 125 | 1/2\\" All floors (including connectivity from TF to regulator) with supply of GI Pipes by Contractor. |
| 126 | 1/2\\" All floors (including connectivity from TF to regulator) - with supply of GI Pipes by Owner on Free Issue Basis. |
| 127 | 3/4\\" All Floors (including Installation of Risers) - with supply of GI Pipes by Contractor. |
| 128 | 3/4 All Floors (Including Installation of Risers) with supply of GI Pipes by Owner on Free Issue Basis. |
| 129 | 1\\" Dia All Floors (for Riser Installations & For Commercial Connections) - with supply of GI Pipes by Contractor (Rates are inclusive of installation by threading; however, in case of pipe joining by welding as per the direction of EIC, payment for welding, NDT will be made separately). |
| 130 | 1\\" Dia All floors (for Riser Installations & for Commercial Connections) - with supply of GI Pipes by Owner on Free Issue Basis (Rates are inclusive of installation by threading, however in case of pipe joining by welding as per direction of EIC, payment for Welding, NDT will be made separately) |
| 131 | Carrying out Seal Welding of GI/CS Pipes as per latest applicable code & standard for above SOR items B00104 to B00107 as per specification, site requirement and instruction of EIC. |
| 132 | Carrying out NDT/Radiography of welded joints of CS/GI Pipes as per the latest applicable code & standard for the above SOR items B00108 as per standard / site requirement and instruction of EIC. |
| 133 | Supply of Nitrogen as an inert gas for preservation at positive pressure and/or other tasks as per site requirements and instructions of EIC (where the supply of Nitrogen is not included in the scope of work mentioned elsewhere in the SOR). |
| 134 | Note:- i) Refer to the Particular Job Specification for the supply items. ii) The quantity measurement shall be from the outlet of the Transition Fitting (TP) up to the Meter. All Intermediate CA fittings & valves, GI fittings & valves (excluding Flexible Hose / Anaconda, meter, and regulator) shall be considered while measuring the length of CS/GI Pipes.iii) Supply of isolation Ball valves shall be paid as a separate SOR Item. iv) In the case of SOR Items B00103, B00105 & B00107 above (under SOR Item No.• B00101), the owner shall supply Plain or Powder Coated GI Pipes (as free Issue). The remaining scope of supplies of fittings, etc., including all associated works will be under contractor scope. |
| 135 | Cutting/Breaking and Restoration |
| 136 | In the case of a multistorey building where RCC slab/visor/sunshade/chhajja restricts riser installation, then separate payment for core-cutting with a heavy-duty drill machine shall be paid under the below SOR item and as per the instructions and direction of EIC. |
| 137 | Breaking/Cutting of Cement Concrete - Making provision for GI Pipe laying |
| 138 | Cement concrete restoration as per the scope of work (excluding breaking/cutting) |
| 139 | Breaking/Cutting of RCC Core - Making provision for GI Pipe Laying |
| 140 | RCC restoration as per scope of work (Excluding Breaking/Cutting) |
| 141 | Supply, Installation, Testing & Commissioning of Copper Service Pipes |
| 142 | Supply and installation of copper tubing and installation of Appliance Ball valves as per Technical specification and alogwith associated acessories/fittings including brass fittings at the outlet of the meter and at the entry of appliance valve as per satisfaction and instruction of EIC. The copper tube and fittings shall be procured from approved vendors who have supplied these items for similar application earlier and with prior approved of Owner / PMC. |
| 143 | Copper tubing shall be installed from the downstream of the meter up to the isolation/appliance valve before the customer's appliance as required and to the satisfaction of the EIC. The contractor is responsible for providing all equipment, tools, tackles, and associated materials necessary to efficiently execute the work by cutting, cleaning, applying flux, soldering, and lacquering. This work includes the supply of all tools, tackles, and consumables, including clamps for fixing the tubes, and the restoration of the work area to the customer's satisfaction. |
| 144 | 12.0 mm OD x 0.6 mm wall thickness |
| 145 | Supply, Installation, Testing & Commissioning of Multi Layer Composite (MLC) Pipes |
| 146 | Supply and installation of MLC Pipe according to the latest ISO17484-1 standard and installation of Appliance Ball valves as per technical specifications along with associated accessories/fittings, including brass fittings at the outlet of the meter and at the entry of the appliance valve as per the satisfaction and instructions of EIC. The MLC Pipe and fittings shall be procured from Jindal /Uniflex Pipe/Any ISI approved make or from vendors who have previously supplied these items for a similar application in any PSU with prior approval from the Owner/consultant. |
| 147 | MLC pipe shall be installed from the downstream of the meter up to the isolation/appliance valve before the customer's appliance as required and to the satisfaction of the EIC. The Contractor must provide all equipment, tools, tackles, and associated materials necessary to execute the work efficiently by cutting, cleaning, bending, fixing with clamps, etc. The work includes the supply of all tools, tackles, and consumables, including clamps for fixing the MLC pipe, and restoration of the work area to the customer's satisfaction. |
| 148 | 16.0 mm OD |
| 149 | Note:i) Supply of Appliance Ball Valves shall be paid as a separate SOR Item.ii) SOR item No. B00400 & B00500 shall be carried out including supply of materials, only after getting instruction / approval from EIC. |
| 150 | Installation of Regulator, Meter, Flexible Hose & Conversion of Domestic/ Commercial etc. Appliance:: |
| 151 | Installation & fixing of meters & regulators (100 m bar to 21 m bar, wherever required) with associated inlet connections/ fittings, valves, approved meter brackets and other supports by proper scaffolding/ grouting,Restoration of the work area to its original condition to the entire satisfaction of EIC. (Meter and Regulator will be provided as as free issue Items) |
| 152 | Installation of Service Regulator: Installation & Fixing of Service regulator Module with associated inlet and outlet. Service Regulator installation as per sketch attached - (4/6 bar to 100 mbar) |
| 153 | COMMERCIAL METER (DIAPHARAM): Installation & fixing of commercial meters alongwith box such as G4, G6,G10, G16, G25, G40,G65 ete with associated inlet and outlet connection fittings, meter brackets(if required), pipe supports etc, by using proper scaffolding. Restoring the area to original completre as per specification. COMMERCIAL METER alongwith box is a free issue material. |
| 154 | COMMERCIAL REGULATORS: Installation & Fixing of commercial regulators (0.5 - 6 bar to 300/500 mbar) - 4 SCMH to 250 SCMH capacity with associated inlet and outlet connection fittings with required supports. Restoring the area to original completre as per specification. COMMERCIAL REGULATOR is a free issue material. |
| 155 | Installation of Commercial RPD Meter and regulator ( Pressure rating more than 0.5 Bar ) with all accessories and Support . (Meter and Regulator will be provided as as free issue Items) |
| 156 | Regulator Boxes: Supply & Installation including painting of approved make regulator boxes and installing them firmly by grouting using approved bracket /clamps as per standard drawing & as per specifications and cleaning the area complete to the satisfaction of EIC. |
| 157 | Supply and installation of Commercial/Industrial meter box. |
| 158 | Conversion of Domestic AppliancesCarrying out the complete works starts from outlet of meters which includes installation of GI pipe,Appliance valve etc & other supports by proper grouting, Restoring the area to original complete as per specification.The work also includes installation and supply of Steel reinforced Flexible Hose as per IS 9573 (with Type as per lastest PNGRB guidelines) (Gas tube from end of Isolation Valve upto burner/stove) and conevrsion of all the burners of the LPG stove (one stove per household) including supply of all types of burner nozzles/jets and associated controls etc. |
| 159 | Complete works as per specification for carrying out cleaning and performing minor maintenance, greasing etc. of appliance, testing/ showing performance to the customer, signing of Joint Meter Records (JMR) and issue of guideline / instructing to customer regarding operation & safety norms during use as per specifications. The issued instruction & guideline should be the entitre satisfaction of customer. |
| 160 | Supply of Valves for Carrying out connection (For Domestic Connections) |
| 161 | Supply of Isolation & Appliance Ball Valves as per Technical Specification and as directed by EIC |
| 162 | Supply and installation of Isolation Ball Valve 1/2 \\" max. 6 bar (g) |
| 163 | Supply and installation of Isolation Ball Valve 3/4 \\" max. 6 bar (g) |
| 164 | Supply and installation of Isolation Ball Valve 1 \\" max. 6 bar (g)) |
| 165 | Installation of Isolation Ball Valve (1/2\\", 3/4\\" & 1\\") max. 6 bar (g):(Valves are in GAIL scope) |
| 166 | Supply and installation of Appliance Ball Valve 1/2 \\" max. 35 mili Bar (g) |
| 167 | Registration of Domestlc PNG Connections |
| 168 | Assistance in conducting Domestic PNG registration work as directed by the Marketing In charge of GAIL (I) Limited / Authorized representative, including but not limited to the following:Enrolling & registering Domestic PNG Customers according to the given target.Collecting filled-up forms,Cheque/Demand Draft for Security Deposit amount and documents. All other necessary activities to complete the work as defined in the Scope of work, to be read along with the Special Conditions of Contract and as per instructions of MIC. Conducting marketing activities for Domestic PNG connection as detailed in Scope of work, complete in all respects, as per directions/instructions of the Marketing In Charge, including but not limited to the following: Distribution of leaflets & FAQ, Installation of banners provided by the client at prime locations, Awareness cum Registration Camp, Audio / Visual Presentations, Organizing Road Shows, etc. |
| 169 | Enrolling and registration of domestic customer and uploading all documents in SAHAJ (Registration without SD) |
| 170 | Collection of Security deposit |
| 171 | Inlet/Outlet piping work for all types of MRS skids and customer-end connection piping, including fabrication of MRS units of all types and capacities. The scope also includes submission of as-built drawings.The work shall comprise supply, erection, welding, installation,testing and painting of carbon steel (CS)/GI pipes and fittings (of all types), along with the supply and installation of all types of valves (Ball, Check, and Globe) required for piping systems and common headers, including necessary branching for industrial and commercial connections. |
| 172 | The work shall comprise supply, erection, welding, installation, and painting of carbon steel (CS)/GI pipes and fittings (of all types), alongwith the supply and installation of all types of valves (Ball, Check, and Globe) required for piping systems and common headers,including necessary branching for industrial and commercial connections. The scope also includes submission of as-built drawings. |
| 173 | In addition to other activities under SOR item no. B00100 and as detailed in specification and as per the instructions and decided by of theOWNER / Consultant. Erection, Fabrication, Welding & Installation for all type of piping and common headers of CS/GI pipes & Fittings, isolationvalves for fixing of numerous meters through a single header and includes connecting of common Regulators on headers, NPT threading, NDTof Joints upto 3\\"CS/GI pipe, Drillings of holes through the walls Brick, RCC, Granite, Marble, Wood Cutting, Glass Cutting with proper heavy dutyhammer drill machine, tools & tackles, using proper sealant/grout material and colors to match the original replacement of the damages duringdrilling, restoring the area to the original condition, Painting of entire length of pipe along with fittings after proper surface finish by one coat ofPainting of entire system (including aboveground all pipes fittings, flanges and accessories) as per tender specification suitable for corrosivearea environment including supply of approved paints and primers, application of primer and paints. Restoring the wall surface to originalconditions, Supply & fixing of approved MS angle clamps, Ceiling clamps & dowel plugs with screws, supply and insertion of insulation materiali.e. PVC, PTFE sheet between pipe/ meter support and pipe/ meter, grout material, suitable thread sealant i.e. Teflon Tape / lock tight, Supply ofdifferent sizes upto 3\\" spiral wound gasket, studs & bolts (various sizes with wire sealing arrangement wherever required), Joining of transitionftg. to above ground CS/GI pipes, welding of CS/GI pipes for customer/industrial customer, testing/hydrotesting (hydrotesting of piping sytem for CS pipe of minimum 4 hour), purging and commission of the complete installation. Supply and installation of STANDARD Y TYPE FLANGE END STRAINER between T.F. I.V. to Regulator Inlet. Strainer size may be upto 3\\"corresponding to installed TF size. The payment for supply and installation of Y type strainer is included in MRS installaion/fabrication. Installation of valve (Ball,Globe, plug, check etc...as per requirement) BW/flange ended is included in MRS installaion /fabrication.NOTE:i). scope of work includes supply of clamps, supports for erection of all sizes of piping/ppeline work.ii). Installation of CS/GI flanges upto 3\\" shall be the scope of contractor.iii) Supply, Erection, welding & Installation of CS/GI pipes & all types of associated fittings is in the scope of contractor.iv) If Consumer is ready / agree complete the work after outlet of MRS/Metering skid outlet (after outlet valve) to commercial/industrial appliancevalve connection Contractor have to take quantity approval from EIC/OWNER prior to order placement. |
| 174 | Transportation including loading, unloading & handling of all piping items from Owner's (if required) and/ or Contractor's storage point to worksite/ workshop as applicable, complete work of fabrication, erection, painting, testing of pipes, flanges and fittings and making ready for furtherCommissioning / Start-up of carbon steel piping of upto 3\\" and ratings including supply of all consumables, equipment, manpower and otherresources and execution of, but not limited to, the following works in accordance with relevant specifications & scope of work, drawings,specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT |
| 175 | Fabrication including cutting, edge preparation, inclusive of grinding the edges of pipes, fittings, flanges etc. to match with the matching edgesof uneven/different thickness wherever required, welding, attachment of all pipe fittings like elbows, tees, reducers. Supply of nipples, couplings,Meter adopter (if required),caps, plugs, Flange, Reducer / Expender to connect up-stream and down stream pipeing, gasket, stud bolts, nuts, UClamps etc. as required for completion of job. |
| 176 | Fixing/ Installation of sockolets, flanges, vent and drain point connection etc., including providing stub-in connections, fabricated fittings andreinforcement pads etc., as required. |
| 177 | Erection including prior cleaning, lifting, placing on pipe clamps and supports, overhead on racks (if required), skids and at all elevationsincluding installation and carrying out connected activities for all types of valves including supply and fixing of gaskets, studs/ bolts, nutswherever required for all sizes, levelling, aligning, joining of flanges, blind flanges, connecting with equipment, nozzles, strainers, tie-in withexisting piping/facilities, etc. tapping for inline instruments like pressure gauges, thermowells (if required), sample connection, etc. |
| 178 | Preparation of final bill of material based on piping GADs. |
| 179 | Preparation of isometric and fabrication drawings. |
| 180 | Carrying out 100 % Non-destructive testing |
| 181 | Surface preparation before application of primer by means of sand blasting including supply of approved quality of sand, manpower,machineries, tools & tackles to achieve required roughness as per specification and as per instruction of Engineer-incharge. |
| 182 | Painting of entire system (including aboveground all pipes fittings, flanges and accessories) as per technical specification suitable for corrosivearea environment including supply of approved paints and primers, application of primer and paints, indentification lettering/ numbering, colourcoding, etc. as specified including rub down & touch up of shop primer or scrapping of shop primer wherever required by EIC/RCM andproviding scafolding for all heights etc. |
| 183 | Cleaning and flushing by water/ compressed air, testing of the systems including hydrostatic, pneumatic and any other type of testing asspecified, draining, drying by compressed air/other methods approved by EIC/RCM/Owner |
| 184 | Precommissioning & making operational all piping system and equipments and provide all necessary assistance in term of supply of man-power,equipment, tools and tackles required amount of nitrogen for purging of entire terminal piping system including equipments etc. to the companyduring commissioning activities. |
| 185 | Clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue material toOwner's designated plac(s); completing all works in all respects as per the AFC drawing, specifications, standards and other provisions ofContract and instruction of Engineer-in-charge. |
| 186 | Completion of all such work in all respects as per scope of work and as per drawings, specifications and instructions of the EIC/RCM/Owner andkeeping the system ready in all respects for further commissioning and start up. |
| 187 | Hook-up works including making provision for hooking up and carrying out shutdown activities at terminals if necessary |
| 188 | Complete Carbon Steel/GI Piping Work with erection, transportation, shifting, painting including all fittings, flanges and supply of allrequired gaskets, studs bolts & nuts etc. |
| 189 | Complete Carbon Steel/GI Piping Work with shifting,transportation, erection, alignment,hydrotesting, dewatering, painting including all fittings, flanges and supply of all required gaskets, studs bolts & nuts etc. ERW GI pipes (Class C) as per IS 1239 Part 1 standard or API 5L Gr. B or ASTM A106 or ASTM A333 |
| 190 | PIPE SIZE- 3\\" NB |
| 191 | PIPE SIZE- 2\\" NB |
| 192 | PIPE SIZE- 1.5\\" NB |
| 193 | 1) All butt welded fittings end shall generally match with connecting pipe wall thickness. However, in case of misalignment,Contractor shall haveto do end preparation without any extra cost.2) Payment of radiography/NDT of joints shall be paid seperately under SOR item for RADIOGRAPHY / NDT mentioned elsewhere in this SOR.3) All fittings, flanges, assorted pipes, gasket, stud-bolt, coupling, nipples etc.of all sizes as required to complete the piping system as per scope of work shall be erected/ installed by contractor but no separate payments shall be made as the same is included under above items rate.4) All piping works shall be carried out as Client/Consultant's piping material specification (PMS).NOTE : If Consumer is ready / agree complete the work after outlet of MRS/Metering skid outlet (after outlet valve) to commercial/industrial appliance valve connection Contractor have to take quantity approval from EIC/OWNER prior to order placement |
| 194 | Welding of joints for laid pipelines (CS/GI) up to a thickness of ≤10 mm shall be carried out by the contractor. The scope includes the provision of all required accessories, consumables, tools, tackles, and machinery necessary for the execution of the work. This also includes conducting Dye Penetrant Testing (DPT) and ensuring compliance with applicable quality standards and safety norms. |
| 195 | Butt welding / Socket welding |
| 196 | RADIOGRAPHY/NDT OF JOINTS |
| 197 | Performance of radiographic inspection by gamma radiation/ X-ray as per scope of work and as per specifications in piping of all types and thickness including providing/hiring of all necessary equipments, supply of all consumables, and whatever else even though not expressely mentioned but required to perform the work as per specifications and instructions of Engineer-in-Charge (full circle re-radiography of the repaired joint and additional radiography necessitated due to poor performance of contractor's welder shall be carried out by the Contractor at his own cost and shall not be paid extra by Company). Radiographs shall be submitted to the Engineer-in-Charge for acceptance, whose decision shall be final and binding.Note- i).Radiography shall be carried out as per API 1104 (latest edition) / BANDR specification / OISD / PNGRB and same shall be approved by Engineer–in–charge (EIC)/ RCM.ii). All socket weld joint are MPT/UT/DPT shall be done and shall be carried out as per API 1104 (latest edition)/ BANDR specification / OISD / PNGRB and same shall be approved by Engineer–in–charge (EIC)/ RCM. Payment of MPT/UT shall be paid under this sor item. |
| 198 | Dia-3\\" |
| 199 | Dia-2\\" |
| 200 | Dia-1.5\\" |
| 201 | Internal/external piping support as per specification/ standard |
| 202 | Type-1, side wall mounted as per drawing |
| 203 | Type-2, ground based as per drawing |
| 204 | Type-3, ceiling mounted as per drawing |
| 205 | Note:- Quantities mentioned against each above sub-item of this SOR are tentative and may increase or decrease during execution of work depending upon site requirement.(The above mentioned work shall strictly comply the PNGRB Industrial and commercial connection standards) |
| 206 | Supply of assorted pipe, fittings, and flanges, etc. As Per IS 1239 (Part-2); IS 1879, ASME B16.9, ASME B16.11, ASTM A234 |
| 207 | Complete work of supply of pipes, fittings and flanges including all taxes, duties, transportation and inspection charges but not limited to thefollowing items in accordance with relevant specifications indicated in clause of SCC & scope of work indicated in SCC, drawings, specificationand instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT. |
| 208 | Handling including lifting, transportation from Contractor Stores to CONTRACTOR's workshop for fabrication and/ or to work sitefor fieldfabrication and erection for all piping items supplied by Contractor. |
| 209 | Supply of Steel Pipes |
| 210 | PIPE ASTM A106 3\\" NBSch. 40, (Charpy) |
| 211 | PIPE ASTM A106 2\\" NB,Sch. 80, (Charpy) |
| 212 | PIPE ASTM A106 1.5\\" NB,Sch. 80, |
| 213 | ERW MS PIPES (CLASS C) AS PER IS 1239 PART-1, 3\\" NB |
| 214 | ERW MS PIPES (CLASS C) AS PER IS 1239 PART-1, 2\\" NB |
| 215 | ERW MS PIPES (CLASS C) AS PER IS 1239 PART-1, 1.5\\" NB, |
| 216 | Pipe API 5L Gr. B, 3\\" NB, |
| 217 | Pipe API 5L Gr. B, 2\\" NB, |
| 218 | Pipe API 5L Gr. B, 1.5\\" NB, |
| 219 | Note:a. Contractor have to take quantity approval from EIC/OWNER prior to order placement.b. All type of piping works shall be carried out as per Client/consultant's piping material specification (PMS) & PNGRB guidelines. |
| 220 | Supply of flanges as per specification/standard ( Rate inclusive of required Stud-bolt , and gaskets as per standard and specification) |
| 221 | Weld Neck (A105, 150#, B-16.5, 125AARH) (End Thickness to match pipe thickness) |
| 222 | NB 3\\" RF |
| 223 | NB 2\\" RF |
| 224 | NB 1.5\\" RF |
| 225 | Blind Flanges (A105, 150#, B-16.5, 125AARH) |
| 226 | NB 3\\" RF |
| 227 | NB 2\\" RF |
| 228 | NB 1.5\\" RF |
| 229 | Supply of spectacle blind (A105, 150#, ASME-B 16.48, 150#, FF/125AARH) as per specification/ standard |
| 230 | Spectacle Blind 3\\" |
| 231 | Spectacle Blind 2\\" |
| 232 | Supply of 90° Elbow 1.5 D ASTM A 234 WPB as per specification/ standard |
| 233 | NB 3\\" (Charpy) |
| 234 | NB 2\\" (Charpy) |
| 235 | NB 1.5\\" |
| 236 | Supply of TEE( Equal / Reducing ) ASTM A 234 GR.WPB as per specification/ standard |
| 237 | Size: 3\\" (Charpy) |
| 238 | Size: 3\\" x 2\\" (Charpy) |
| 239 | Size: 2\\" (Charpy) |
| 240 | Size: 2\\" x 1.5\\" (Charpy) |
| 241 | Size: 1.5\\" |
| 242 | Supply of SOCKOLET ASTM A234 WPB, as per specification/ standard |
| 243 | Size: 2\\" x 1\\" |
| 244 | Size:2\\" x ¾\\" |
| 245 | Size:2\\" x 1/2\\" |
| 246 | Size:1.5\\" x 1\\" |
| 247 | Supply of End Caps ASTM A 234 GR.WPB, as per specification/ standard |
| 248 | NB 3\\" (Charpy) |
| 249 | NB 2\\" (Charpy) |
| 250 | Supply of Reducer ASTM A 234 GR.WPB ,as per specification/ standard |
| 251 | Size: 3\\" x 2\\" (Charpy) |
| 252 | Size: 2\\"x1\\" (Charpy) |
| 253 | Size: 2\\" X 1.5\\" (Charpy) |
| 254 | Size: 1.5\\" x 1\\" |
| 255 | Note:a) All butt welded fittings end shall generally match with connecting pipe wall thickness however in case of misalignment Contractor shall have to do end preparation without any extra cost. |
| 256 | b) All coupling, nipples etc. as required shall be supplied by contractor but no separate payments shall be made as it is covered under erection rate. |
| 257 | c) Quantities mentioned against each above sub-item are tentative and may increase or decrease duringexecution of work depending upon site requirement. |
| 258 | NOTE : i) If Consumer is ready / agree complete the work after outlet of Skid/Metering skid outlet (after outlet valve) to commercial/industrial appliance valve connection Contractor have to take quantity approval from EIC/OWNER prior to order placement.ii). All type of piping works shall be carried out as per client/consultant's piping material specification (if any conflict). |
| 259 | Supply & Installation of Valves |
| 260 | The scope includes supply, transportation, loading, unloading, painting, installation, testing, and commissioning, complete in all respects, including all applicable taxes, duties, and inspection charges, but not limited to the following items, in accordance with relevant specifications, data sheets, scope of work as defined in the SCC, drawings, and instructions of the Engineer-in-Charge (EIC), and as per all provisions of the Contract Document.This includes the supply and insertion of nipples at all elevations, and associated components such as pipe clamps, supports and painting of valves as per standards.The scope further covers the supply of all consumables, manpower, and equipment required for the completion of all works, as per drawings, specifications, and EIC instructions. This also includes servicing and cleaning of valves wherever required.Additionally, the supply of extra stud bolts and gaskets, as required beyond the flange scope of supply, is included in the quoted SOR rate.Note: Welding of joints for welded valves shall be paid under a separate SOR item, as specified elsewhere in the Schedule of Rates (SOR). |
| 261 | Supply & Installation of Globe valves ( Fire Safe) as per specification/standard |
| 262 | 3\\" 150# |
| 263 | 2\\" 150# |
| 264 | 1-1/2\\" 800# |
| 265 | Supply & Installation of Ball Valves ( Fire Safe) as per specification/ standard |
| 266 | 3\\" 150# |
| 267 | 2\\" 150# |
| 268 | 1-1/2\\" 800# |
| 269 | Supply & Installation of Check valve/NRV as per specification/ standard |
| 270 | 3\\" 150# |
| 271 | 2\\" 150# |
| 272 | Supply and installation of brass isolation valve including necessary Hex Nipple and fittings for as per specification/standard |
| 273 | 1-1/2\\" |
| 274 | SUPPLY & INSTALLATION Y-Type Strainer |
| 275 | Y-TYPE STRAINER - 1.5\\" 150# flange end |
| 276 | Y-TYPE STRAINER - 2\\" 150# flange end |
| 277 | Y-TYPE STRAINER - 3\\" 150# flange end |
| 278 | Supply of Pressure Gauges with all accessories |
| 279 | RANGE 0-100 MBAR - 4\\"- DIAL SIZE |
| 280 | RANGE 0-1 BAR - 4\\"- DIAL SIZE |
| 281 | RANGE 0-4 BAR - 4\\"- DIAL SIZE |
| 282 | RANGE 0-6 BAR - 4\\"- DIAL SIZE |
| 283 | Providing the Services of Resources as per site requirement |
| 284 | Providing the services of Plumber(Manday= 8 Working Hours) |
| 285 | Providing the services of HeIper(Manday= 8 Working Hours) |
| 286 | Providing the Services of Welder(Manday= 8 Working Hours) |
| 287 | Providing the Services of EIetricIan(Manday- 8 Working Hours) |
| 288 | Providing the Services of Conversion Technician(Manday= 8 Working Hours)s) |
| 289 | Providing the Services of Grinder(Manday- 8 Working Hours) |
| 290 | TPIA certification for Commercial/Industrial/ domestic customer connections shall be obtained as per PNGRB guidelines before commissioning of the line, along with all required Third Party Inspection Certificates and supporting documents as per PNGRB norms |
| 291 | Note for all above SOR Items Nos. A00100 to H00101 :-i) Quantities mentioned against all above SOR items are estimated & tentative and may vary up to any extent as per site condition and/or as per instruction of EIC.ii) If certain documents, drawings, datasheets, specifications etc. are not included in the bid, the same will be made available to the successfull bidder. While formulating the bid, bidders are requested to quote such items based on practices followed by the similar nature of industries. However procurement & installation of such items will be done as per site requirement after due approval of EIC. |
| 292 | Note:- Services of Safety Officer must be provided by the contractor during execution of any Works as mentioned in the SOR items under this tender . Safety Officer will report to EIC and liable to follow his instruction time to time during their deputation at work site. The cost of deputation of Safety Officer at works site is included in above SOR items rates . Incase of non deployement of Safety Officer during execution of works at site and/or as per instruction of EIC, penalty will be levid to contractor as per rate/ amount mentioned in Annexure-10 to SCC enclosed with the tender document and the same will be deducted from their RA Bill. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail