| 1 | Construction of 33KV line from Jahajduba 132/33KV GSS to Jamuguri 33/11KV DSS under Jamuguri Electrical Sub-Division (excluding River crossing and tower crossing) of Tezpur EC on Turnkey Mode. [line Length - 15.02 km](refer Annexure-1)Itemwise price should be filled in strictly as per the detailed Bill of Quantities at respective referred Annexure. |
| 2 | Construction of 33KV line from JAHAJDUBA 132/33KV GSS TO Jamuguri 33/11KV DSS for the River crossing part at Chakighat NHIDCL under Jamuguri ESD of Tezpur EC. [line Length - 1.2 km](refer Annexure-2)Itemwise price should be filled in strictly as per the detailed Bill of Quantities at respective referred Annexure. |
| 3 | Construction of 33KV line from JAHAJDUBA 132/33KV GSS TO Jamuguri 33/11KV for the Tower crossing point under Jamuguri ESD of Tezpur EC.[ line length 0.3 M MVCC](refer Annexure-3)Itemwise price should be filled in strictly as per the detailed Bill of Quantities at respective referred Annexure. |
| 4 | GI Steel Tubular Pole SP-76 (14.50) |
| 5 | ACSR \\" WOLF\\" Conductor |
| 6 | Disc Insulator (Polymeric) 90kN (B&S Type) |
| 7 | H/W fitting for Disc Insulator B&S 90kN tension type |
| 8 | Polymeric Pin Insulator (FRP 34mm) |
| 9 | PG Clamp for ACSR Wolf |
| 10 | GI Top Cleat (100x50x6x350)mm for 33KV |
| 11 | GI 33KV \\"V\\" Cross Arm with channel size 100x50x6mm |
| 12 | GI Channel Cross Arm (100x50x6x3200mm) |
| 13 | HT Stay Set |
| 14 | Hot Dip GI Wire 8 SWG |
| 15 | GI earthing Pipe 50mm dia 3m length 3.15 mm thickness with perforated holes of 15mm dia at 30 cm interval along length of the pipe |
| 16 | GI Angle (50x50x6)mm |
| 17 | Guy Insulator (Porcelain) |
| 18 | 33KV Danger Plate |
| 19 | GI Barbed wire Type A |
| 20 | Jointing sleeve for Wolf |
| 21 | Pole Clamp of GI Flat 50x6mm |
| 22 | Hot Dip GI Wire Stay Wire 7/10 SWG (For HT) |
| 23 | Gi Nuts Bolts & Washer |
| 24 | Grouting & mufflering of steel tubular pole of type SP-66 and SP-76 as per specification and drawing with minimum planting depth of 2.15 m (using PCC) |
| 25 | Grouting of Stay Set with PCC and Boulder |
| 26 | 33KV grade (Armoured) XLPE cable (Alluminium) 1C x 400 sq.mm. |
| 27 | 33kv XLPE Cable kit 1C x 400 sq.mm. |
| 28 | HDPE pipe 110mm dia 6m length |
| 29 | Perforated Cable Tray having dimension 600mm (width) x150mm(height) x3mm(thickness)alog with all necessary accessiories forfixing at Bridge as per drawing |
| 30 | GI cross Arms (L-shape) 50x50x6mm for fiting of Tray as designed |
| 31 | Through jointing kit 400sqmm1C |
| 32 | CI span pipe class 1A type 300mm dia .5.5long |
| 33 | Socket for CI spun pipe 300mm dia |
| 34 | Clamp for Cable |
| 35 | 33KV pin insulator Polymer |
| 36 | Lug assorted |
| 37 | 33KV 10KA Lightning Arrestor (Line Type) |
| 38 | GI Strip 25x3mm for LA earthing |
| 39 | Gi Nuts Bolts & Washer |
| 40 | Tension Insulator 33 kV 1C x 241 sqmm AAAC Covered Conductor |
| 41 | Tension Hardware 33 kV 1C x 241 sqmm AAAC Covered Conductor |
| 42 | Cable Tie 33 kV 1C x 241 sqmm AAAC Covered Conductor |
| 43 | 33 kV 1C x 241 sqmm AAAC Triple extruded Covered Conductor |
| 44 | IPC 33 kV 1C x 241 sqmm AAAC Covered Conductor |
| 45 | Gi Nuts Bolts & Washer |
| 46 | GI Channel Cross Arm (100x50x6x3200mm) |
| 47 | GI earthing Pipe 50mm dia 3m length 3.15 mm thickness with perforated holes of 15mm dia at 30 cm interval along length of the pipe |
| 48 | GI Angle (50x50x6)mm |
| 49 | Meter Cabinet |
| 50 | GI Strip 25x3mm for LA earthing |
| 51 | 33KV 10KA Lightning Arrestor (Line Type) |
| 52 | Bi-metalic -95 Sq mm Please Enable Macros to View BoQ information |