Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #55710939

Tender For Requirement Of Electrical Wiring In Ced-Signature Lab (Ced) And Requirement Of Electrical Wiring In Measurement Lab (Eed).

Issued by Boards / Undertakings / PSU · Prayagraj, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Jun 2026
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Requirement Of Electrical Wiring In Ced-Signature Lab (Ced) And Requirement Of Electrical Wiring In Measurement Lab (Eed).

BOQ

Name of Work:- Requirement of electrical wiring in CED-Signature lab (CED) and requirement of electrical wiring in Measurement lab (EED).
Sl. No. Item Description
1Requirement of electrical wiring in CED-Signature lab (CED) and requirement of electrical wiring in Measurement lab (EED).
2Wiring for light point/ fan point/ exaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper condutor single core cable in surface/ recessed medium class PVC conduit with modular swtich, modu;lar plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core etc. are required. complete in all respect.Make- Anchor Roma, Havells crabtree, C&S. Wire Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells.
3Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Complete in all respect.Make- Anchor Roma, Havells crabtree,C&S.
4Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Complete in all respect.Make- Anchor Roma, Havells crabtree,C&S.
5Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
6Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire
7Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 2 X 6.0 sq. mm + 1 X 6.0 sq. mm earth wire
8Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 4 X 6.0 sq. mm + 2 X 6.0 sq. mm earth wire
9Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 4 X10 sq. mm + 2 X 6 sq. mm earth wire
10Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 4 X16 sq. mm + 2 X 6 sq. mm earth wire
11Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections,testing and commissioning etc. as required.complete in all respect.Make- L&T, Havells, Legrand, HPL, C&S. Single pole
12Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections,testing and commissioning etc. as required.complete in all respect.Make- L&T, Havells, Legrand, HPL, C&S. Triple pole and neutral
13Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. Complete in all respect. (But without MCB/ RCCB/ Isolator). Make- L&T, Havells , Legrand, HPL,C&S,ABB, Schnieder, Simens. 6 way , Double door
14Supplying and fixing following ways , horizental type three pole and neutral sheet, MCB distributiom board, 415 V, on surfce/ reces, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (but without MCB/ RCCB/Isolator/ MCCB) as required . complete in all respect. Make- L&T, Havells , Legrand, HPL,C&S. 4 WAY (4+12 ), Double Door
15Supplying and fixing following ways , horizental type three pole and neutral sheet, MCB distributiom board, 415 V, on surfce/ reces, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (but without MCB/ RCCB/Isolator/ MCCB) as required . complete in all respect. Make- L&T, Havells , Legrand, HPL,C&S. 8 WAY (4+12 ), Double Door
16Supplying and fixing following ways on surfce/ reces mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCB/ Incomer/ RCCB/Isolator/ MCCB) as required (Note- Vertical type MCB TPDB is normally used where 3 phase outlets are required) .complete in all respect as per site requirement. Make- L&T, Havells , Legrand, HPL,C&S. 4 WAY (4+12), Double Door
17Supplying and fixing following ways on surfce/ reces mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCB/ Incomer/ RCCB/Isolator/ MCCB) as required (Note- Vertical type MCB TPDB is normally used where 3 phase outlets are required) .complete in all respect as per site requirement. Make- L&T, Havells , Legrand, HPL,C&S. 8 WAY (4+24), Double Door
18Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make- L&T, Havells, Legrand, HPL, C&S. 200 Amp, 16 KA,TPMCCB
19Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
20Supply and fixing of two number 8 SWG copper wire in 15 dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the post of cement, sand, labour, T&P other material required for proper completion of the work with 2 Nos.8 SWG copper wire. complete in all respect.
21Supply & laying of 70 sq mm x 3-1/2 core aluminium conductor XLPE armored served aseathed cable 1100 volts grade of following size at suitable depth below ground level over cushion of 75 mm thick sand alround and protected with well burnt bricks on & along the cable & back filling after digging the soil & it back filling/ on wall/ floor the cable run cancealed manner, with cutting and plastering, complete in all respect as per direction of engineering incharge. The armouring of cable shall be properly connected with the earth terminal of the pole panel and as required lugs,, gland etc. Make- Gloster, Kalinga Premium, Rallision, Havells, KEI, R.R.Kable.
22Supply & laying of 35 sq mm x 3-1/2 core aluminium conductor XLPE armored served aseathed cable 1100 volts grade of following size at suitable depth below ground level over cushion of 75 mm thick sand alround and protected with well burnt bricks on & along the cable & back filling after digging the soil & it back filling/ on wall/ floor the cable run cancealed manner, with cutting and plastering, complete in all respect as per direction of engineering incharge. The armouring of cable shall be properly connected with the earth terminal of the pole panel and as required lugs,, gland etc. Make- Gloster, Kalinga Premium, Rallision, Havells, KEI, R.R.Kable, Grandly, V-Marc.
23Supplying, installation , testing & commissioning of following capacity End feed unit for the existing air insulated compact type bus trrunking/ rising main for on 3 phase 4 wire 415 volt, 50 Hz A.C. supply made with 1.6mm thick steel sheet enclouser (IP54) duly power coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets , angle iron bracket stell fastners, connecting to earth system etc. as required. complete in all respect. 200A to 250 A, Isc= 15kA for 1 sec.
24Supplying and fixing of 63 Amp. 4 pole MCB (10 KA) C Curve in the existing MCB DB complete with connections, testing and commissioning etc. as required.complete in all respect.Make- L&T, Havells, Legrand, HPL, C&S. CAT-B
25Supplying & fixing of 6 Amp. to 32 Amp. 4 pole MCB (10 KA) C curve with suaitable box. complete with all connection, testing commissioning etc as required.complete in all respect.Make- L&T, Havells, Legrand, HPL, C&S. CAT-B
26Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make- L&T, Havells, Legrand, HPL, C&S. 200 Amp, 25 KA,TPMCCB
27Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make- L&T, Havells, Legrand, HPL, C&S. 250 Amp, 25 KA,TPMCCB
28Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make- L&T, Havells, Legrand, HPL, C&S. 100 Amp, 16 KA,TPMCCB
29Supplying and fixing 20 amps, 240 V, SPN industrial type ,socket outlet,with 2 pole and earth metal enclosed plug top along with 20 amps 'C' series SP MCB, in sheet steel enclouser, on surface or in recess with chained matel cover for the socket outlet and complete with connections, testing and commissiong etc. as required.complete in all respect. Make- L&T, Simens, Legrand, HPL, Havells, C&S.
30Supply, installation, testing and commissioning of ceiling fan, including wiring the down rods of 90 cm with 1.5 sq mm FRLS PVC, insulated, copper condutor, single core cable, etc. as required. Complete in all respect
31Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. Bar, bent to shap with hooked ends in R.C.C slabs or beam during laying, including painting the exposed portion of loop, all sa per standered design complete. Complete in all respect.
32Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. complete in all respect. Make- Bajaj, orient PSPO, Crompton,Havells, C&S.
33Supply & fixing of 36 watt to 46 watt above 3300 leumin indoor recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate material and driver set complete in all respect.Make- Bajaj, Philips, Havells,C.G. (CAT- A)
34Supplying and making end termination with aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 70 sq mm
35Supplying and making end termination with aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 35 sq mm
36Supplying and making end termination with brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 70 sq mm. x 3-1/2 core
37Supplying and making end termination with brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 35 sq mm. x 3-1/2 core
38Supply & fixing of LED tube light with batten suitable for 1x 18 watt to 22 watt LED tube light complete including tube etc on surface complete in all resepect. Make- Bajaj, Philips, Osram, C&S. (CAT-AA)
39Dome Camera 2 MP. Make- Sparsh/ CP Pluse/ Hikvision
408 CH. NVR. Make- Sparsh/ CP Pluse/ Hikvision
411 TB Hard Disk.
428 CH. POE Swiotch 8+2.
43UTP Cat-6 cable.
442 U Rack.
45Installation + Accessories
46Dismantaling of old installation with proper finishing of dismantaled portion including cost of material, labour, T&P for proper finishing of work. Complete in all respect. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55710939
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 03-06-2026
Authority
Authority Name Motilal Nehru National Institute Of Technology
Work Description Tender for Requirement Of Electrical Wiring In Ced-Signature Lab (Ced) And Requirement Of Electrical Wiring In Measurement Lab (Eed).
Basic Detail
Tender No 05/ESWM/2026-27
Bidding Type Tender
Location
City Prayagraj
State Uttar Pradesh
Key Dates
Publish Date 27 May 2026
Submission Date 03 Jun 2026
Open Date 04 Jun 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_957025.xls
e6451c26-b83d-4b2f-8b45-2682a0eeeb5a.html
TenderFormEN05.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_957025.xls

html

e6451c26-b83d-4b2f-8b45-2682a0eeeb5a.html

pdf

TenderFormEN05.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender