| 1 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 2 | Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 3 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. |
| 4 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 5 | Neat cement punning. |
| 6 | Providing and applying white cement based putty of average thickness 1 mm @ 6 kg per 10 sqm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 7 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 8 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 9 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) |
| 10 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 11 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area beyond 3 sq. metres |
| 12 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 13 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 14 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 15 | Providing and fixing of 57mm thick single / double leaf wooden fire resistant doors having 120 minutes fire rating Single / Double leaf door, conforming to BS:476 part 22 IS: 3614 part II, specifications similar to that of prototype tested & certified at CBRI ROORKEE to be fixed with necessary stainless steel ball bearing hinges of size 100x75x3mm of approved make and has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx.) C/C. the shutter shall be comprising of 2 non-metallic, asbestos free boards each 10 mm thick sandwiching 31mm thick fire resistant insulation filler faced with 3mm thick commercial ply on both faces alongwith 1.0 mm thick regular shade laminated (approved shade) on both side of shutter with Hardwood lipping all around the shutter with heat activated Intumescent fire seal strips of size 10x4mm on all sides except bottom shutter in desired shade as per NBC 2016, IS 16231 (Part 3): 2016 and directions of Engineer-in-charge. |
| 16 | Providing and fixing frame for fire resistant glazed shutters & glazed Partition for 120 minutes Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge made out of minimum 1.20mm thick GI sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested in latched condition as per IS 17518 ( Part-10: 2022 Frame: The Frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as perIS 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E-84 of minimum size 10 x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK/Hes headed fastner of minimum 8mm dia size and minimum 80mm long hot dip galvanized with 8mm dia Polyamide sleeves @ 5 number at each on vertical sides and 3 number on top side. Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge. Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer. |
| 17 | Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly, for staircase / exit pathway and refuge areas applications, consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3612 : 2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20mm thick GI sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested in latched condition as per IS 17518 ( Part-10: 2022 Frame: The Frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as perIS 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E-84 of minimum size 10 x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK/Hes headed fastner of minimum 8mm dia size and minimum 80mm long hot dip galvanized with 8mm dia Polyamide sleeves @ 5 number at each on vertical sides and 3 number on top side. |
| 18 | Door Shutter: The double skinned double leaf partially insulated door shutters shall be consisting of minimum 50 mm thickness an having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resing bonded mineral wool / ceremic wool infill material of minimum density 96 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.06sqm. of 120 minutes fire rated minimum 6mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size of 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of mimimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaves. Integral astragals to be provided for double leaf door on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935 : 2002 or butt hinges as per IS 12817, of minimum size 100x75z3mm @ 5 numbers hinges upto 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. |
| 19 | Accessories Hardware : Fire doorset assembly shall be provided with one number of single point panic push bar (cross bar) for active leaf and one number double point panic push bar (cross bar) with bottom strike of desired finish with verticle shoot bolts on top and bottom for inactive leaf of double leaf door as per EN 1125, one number external trim with half cylinder 42mm long with one side key as per EN 1125, two number heavy duty door closers of size EN 3-5 with standard arm with of desired finish (suitable for 1250 mm wide door leaf) conforming to IS 3564 / EN 1154, and one number surface mounted door coordinator for sequencing of closing. Finishing : Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge. Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer. |
| 20 | Double leaf partally insulated metal fire rated door set of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614 :20221 for staircase/Exit /pathway/ Refuge area etc. |
| 21 | Providing and Fixing Approved Make Door Closer with Std Armt TS1000 all complete as per the direction of Engineer-in-Charge. |
| 22 | Providing and Fixing Approved Make Dead Lock With 70mm EPC Both side Key all complete as per the direction of Engineer-in-Charge. |
| 23 | Providing and Fixing Approved Make D Type Pull Handle 300x19mm Back to Back all complete as per the direction of Engineer-in-Charge. |
| 24 | Providing and Fixing Self Adhesive Smoke Seal of 3 side frame all complete as per the direction of Engineer-in-Charge. |
| 25 | Providing and Fixing Approved Make Concealed Flush bolt 600mm Long all complete as per the direction of Engineer-in-Charge. |
| 26 | Providing and Fixing approved Make 6mm Thick FR Clear FR Glass of Size 200x300mm for Vision Panel all complete as per the direction of Engineer-in-Charge. |
| 27 | Add difference of Water Charges @ 0.50% |
| 28 | Credit Material (Old) |
| 29 | Wooden door frame and shutter (double leaf) with fittings completed. Please Enable Macros to View BoQ information |