| Sl. No. | Item Description |
| 1 | Sub-Head 01--Distribution Wiring |
| 2 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish |
| 3 | Average run 8 mtr |
| 4 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm/25 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. |
| 5 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 6 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (for computer board, PP) |
| 7 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (for 4x16 power board) |
| 8 | 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC (from PBDB to LBDBs) |
| 9 | 4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC (For Starilizer & UPS Connection) |
| 10 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required |
| 11 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC as ECC for VTPN to TPN DB |
| 12 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 13 | 25mm size |
| 14 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required |
| 15 | 4x 84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC ( Starilizer room MCB & UPS Connection) |
| 16 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S |
| 17 | 2.5 sqmm |
| 18 | 4 sqmm |
| 19 | 6 sqmm |
| 20 | 10 sqmm |
| 21 | SUB-HEAD 02-- PLUGS & SOCKETS |
| 22 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/ perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 23 | Supply & Fixing 240 V, 4 nos. 20A plug socket with separate 4 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (approved make) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 24 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x 200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 25 | SUB-HEAD 03--BDB,PDB,VTPN ETC |
| 26 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 27 | 6 way (upto 160 A) (AC DB) |
| 28 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, on surface of wall by clamp arrangement & mending good the damages to original finish incl. cable end box and Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 29 | 6 Way |
| 30 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 31 | 2+10 way |
| 32 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 33 | 415V, 63A, FP |
| 34 | 240V, 40A, DP |
| 35 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 36 | 125 A, 4P |
| 37 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 38 | 6-32 A, SP |
| 39 | 40 A, TP |
| 40 | 63 A, FP |
| 41 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment |
| 42 | For 6 way VTPN |
| 43 | Supplying and fixing 415V, on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 44 | Supplying and fixing 240/415 V change over (MCB module) of on din rail of existing DBs/ enclosure and necessary connection. [Make: Legrand / ABB / SIEMENS / Schneider /L&T] (For UPS bypass connection) |
| 45 | 40 A, 4P |
| 46 | Supplying and fixing 4 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment [Make: Legrand / ABB / SIEMENS / Schneider /L&T] |
| 47 | SUB-HEAD 04--Supplying & Laying of Cable |
| 48 | Supply of 2/4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] |
| 49 | 2 CORE 6 SQMM (for compound light) |
| 50 | 4 CORE 50 SQMM (from Blood Bank Panel to Light & AC VTPN) |
| 51 | 4 CORE 95 SQMM (from Blood Bank Panel to Gr. Fl LT Panel C/O) |
| 52 | 4 CORE 150 SQMM (from Main LT Panel to Blood Bank Panel) |
| 53 | Supply & Fixing of 150x50x12.5 mm (18 SWG) perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. (With 25x25x3 mm angle iron support) |
| 54 | 200x50x1.25mm )18 SWG) |
| 55 | 300x50x1.25mm (18SWG) |
| 56 | Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 57 | 200x50x1.25mm (18SWG) |
| 58 | 300x50x1.25mm (18SWG) |
| 59 | Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 60 | 300x50x1.25mm (18SWG) |
| 61 | Supply & Fixing of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the reducer incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 62 | 300x50x1.25mm (18SWG) |
| 63 | Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. Up to 150 sqmm |
| 64 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 65 | Laying of cable above 3½ core 95 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 66 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 67 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 68 | 2 CORE 6 SQMM |
| 69 | 4 CORE 50 SQMM |
| 70 | 4 CORE 95 SQMM |
| 71 | 4 CORE 150 SQMM |
| 72 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 73 | 2 CORE 6 SQMM |
| 74 | 4 CORE 50 SQMM |
| 75 | 4 CORE 95 SQMM |
| 76 | 4 CORE 150 SQMM |
| 77 | Supplying & fixing 80 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 78 | SUB-HEAD 05---SUPPLY OF LIGHT FITTINGS |
| 79 | Supply & Delivery of following LED Industrial Batten light (System lumen efficacy ≥110 lm/Watt) made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap), Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV with Short & Open circuit protection , |
| 80 | THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 40000 Burning Hours, with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). |
| 81 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).[Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 82 | Single Batten Fittings (1 x 18/20 Watt) |
| 83 | Double Batten Fittings (2 x 18/20 Watt) |
| 84 | SUB-HEAD 06-- FIXING OF LIGHT FITTINGS |
| 85 | Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. |
| 86 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener |
| 87 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 88 | SUB-HEAD 07 -- SUPPLY OF FANS |
| 89 | Supply & Delivery of 230V, 1-phase AC ceiling fans incl. all accssories, the capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan. [Make: Crompton / Usha/ Havells/ Orient] |
| 90 | Sweep Size- 1200 mm (48\\"), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M |
| 91 | Supply & Delivery of 230V, 1-phase AC exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust fan of following diameter, complete as required. [Make: EPC / Crompton / Usha /Havells/Orient] |
| 92 | 300 mm (12\\"), 4 Blade, RPM ≤ 1420 , Wattage ≤ 82 Watt, Sound level ≤ 56 dB, Air Displacement (In CFM) ≥ 1120 |
| 93 | Supply & Delivery of 230V, 1-phase AC wall mounting bracket fan (metal body & metal blade) on wall incl. S&F of MS fastners and nut & bolts etc. as reqd. [Make: EPC / Crompton / Usha/Havells/Orient] |
| 94 | 450 mm sweep, Wattage ≤ 90 Watt, RPM ≤ 1325, Air Displacement (In CFM) ≥ 3550 |
| 95 | SUB-HEAD 08-- FIXING OF FANS |
| 96 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991). |
| 97 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. |
| 98 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS |
| 99 | Supply & Fixing fan down rod (14 SWG- white MS pipe zinc plated) having 19 mm OD 1.8 +/- 0.05 mm thick complete with cutting, making holes for fixing the fan incl. necessary connection wire (2X1.5sqmm cu wire) as per direction of EIC (Rate in per feet) |
| 100 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter |
| 101 | 30cm (12\\") |
| 102 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 103 | For 30 cm Exhaust fan (12\\") |
| 104 | SUB-HEAD 09-- Compound Light |
| 105 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 45o C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66, IK - as specified below, CRI >70, |
| 106 | under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, |
| 107 | Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90o C). System lumen efficacy ≥110 <135 lm/Watt (IK-8) [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] |
| 108 | 60 Watt |
| 109 | Supply & erection of mini pole of size 1.8/ 2 Mtr. long & 80 mm. dia (ISI Medium) on roof top by providing CC (6:3:1) base block (around the pole) having dimension of 0.45 x 0.45 x 0.60 mt. above roof level, neatly cemented finish (3 mm thick) incl. arrangement for suitable entry for cable/alkathene/polythene pipe , for street light wiring (without Loop Box) with hole for smooth cable entry at appropriate position and having 15 mm. thick stifner plates duly welded to base plate & pole base as per direction of E.I.C. |
| 110 | Supply and Fixing of single arm header assembly fabricated from 40mm dia. GI Pipe (ISI-M) having length 1500 mm, rigidly welded with 100 mm dia. GI Pipe (ISI-M) of 0.3 Mtr. long as pole sleeves at an angle of 105⁰ including S/F 3 Nos ½” MS jam nut each with 1No. ½” dia. through bolt, pole cap and painting as to GS of the entire assembly. |
| 111 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 112 | Supply & Drawing 1.1 KV grade 3cCore 22/0.3 (1.5 sqmm) XLPE insulated Un-armoured Cu Cable (Brand approved by EIC) for connection from loop box to fittings through the Pole including making connections as necessary. |
| 113 | S&F of 250V, 25A timer controlled single starter for controlling compound lights/ Single Air Conditioning Machines in SS double door 2+10 way DB enclosure (L&T / ABB / Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm2 copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl. necessary connections as per direction of EIC : - |
| 114 | 25A DP MCB (L&T / ABB / Legrand make) – 1 no. |
| 115 | 24Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) – 1 no. |
| 116 | 3-pole power contactor (L&T make Cat no MNX22 / 250V) – 1 no. |
| 117 | 2-Modular AC motor starter (Legrand / Myrius Cat no 673031) – 1 no. |
| 118 | 1-Module 10A Modular switch (Make Legrand / Myrius) – 1 no. |
| 119 | 3-module plate with cover (Make Legrand / Myrius) – 1 no. |
| 120 | 25A Auto-Off-Bipass SPDT toggle switch (approved reputed make) – 1 no. |
| 121 | LED indication lamp (approved reputed make) – 1 no. |
| 122 | Outgoing bakelite connector 32A (Reputed make as approved by EIC) – 2 nos. |
| 123 | SUB-HEAD 10 --SITC of Cubical Panel |
| 124 | Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. |
| 125 | Construction Details : |
| 126 | All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side. |
| 127 | Incoming Arrangement : |
| 128 | a) 415V 200 Amps Four Pole MCCB of Breaking capacity 36kA/50kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing enclosure and necessary connection (open execution type) (Make: L&T /Legrand /Schenider /ABB/ Siemens)---- 1 No. |
| 129 | b) 415 Volts, 200 Amps, on load front operated TPN changeover switch (open execution type) (Make: L&T /Legrand /Schenider /ABB/ Siemens)- 1No. |
| 130 | Bus bar section : |
| 131 | 415 V, 315 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification- 1 set. |
| 132 | The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications. |
| 133 | Outgoing Arrangement : |
| 134 | a) 415V, 160 Amps Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing enclosure and necessary connection (open execution type) (Make: L&T/Legrand/Schenider/ABB/ Siemens)---- 1 No. |
| 135 | b) 415V, 100/125 Amps Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing enclosure and necessary connection (open execution type) (Make: L&T/Legrand/Schenider/ABB/ Siemens)---- 5 No. |
| 136 | c) 415V, 63 Amps Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing enclosure and necessary connection (open execution type) (Make: L&T/Legrand/Schenider/ABB/ Siemens)---- 2 No. |
| 137 | d) E.I. Danger Board of suitable size ------- 1 no. |
| 138 | Metering Panel:- |
| 139 | a)Digital multifunction meter with selector push button switch (up/down) with Voltage, Current, Frequency, Total Harmonic Distortion, PF, KW, KVA, Kwh, KVAh and Preloaded Max & Min Demand with Date & Time Stamping display (Make-Schneider Electric/ Cat No- EM6400NG Class accuracy CIo.5S, POP of Accuracy Class 0.5S or equivalent model of Legrand/ Siemens/ L&T) - 1 No. |
| 140 | b) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Siemens cat.no 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent cat of L&T/ABB/ SCHNEIDER) - 3 No. |
| 141 | c) 500/5 Amp ratio C.T (Kappa or equivalent) --- 3 nos. |
| 142 | d)S & F 2 Amp SPMCB for auxiliary supply to meters (Make- SIEMENS/L&T/Legrand) - 1 no. |
| 143 | Interconnection :- |
| 144 | All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads. |
| 145 | Earthing Arrangement :- |
| 146 | A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size G.I. strip. |
| 147 | The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. |
| 148 | Installation :- |
| 149 | The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. |
| 150 | SUB-HEAD 13--SITC of Lightning Conductor |
| 151 | S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered/ welded with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1), including thimble joints of 7/16 SWG wire and (25 x 6) mm GI strip with SS nuts, bolts & washers. |
| 152 | Supply & fixing of 25 mm x 6 mm thick GI (Hot Dip) flat / strips for Horizontal & Vertical run on wall / floor with GI shaddles as required including drilling holes, bolts, nuts, washers, etc./ and mending good the damages to building works. |
| 153 | Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:i) Length upto 0.5 Mtr |
| 154 | ii) Length above 0.5 Mtr |
| 155 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. |
| 156 | Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long on wall after making suitable arrangement to establish a clearance of 50mm from wall for making junction connection with vertical conductor and conductor from earth electrode complete with S & F GI bolts, nuts, check-nuts, spring washers etc. as required. |
| 157 | Earthing with 65 mm dia GI pipe (TATA-Medium) 3.0 Mts. long with welded 2 nos. half circle bracket made of GI strip (65 x 8) mm. with two holes on extended portion of the each strip of length min. 250 mm , and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. |
| 158 | Excavation of soil for installation of Earth Electrode and filling & ramming as to GS [For soft soil]. |
| 159 | Supply, Laying & Fixing of 50mm x 6mm galvanized (Hot Dip) steel strip in underground trench for interconnection between the Earth Points by joining (As per item no 11). |
| 160 | Jointing for Horizontal & vertical run of GI strip through welded joint of (25 x 6) mm or (50 x 6) mm GI Strip to Lap joints/ 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint. |
| 161 | SUB-HEAD 12:-- Earthing Installation |
| 162 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For Morrum Soil) |
| 163 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: |
| 164 | By ISI-Medium GI pipe [For DG Body- 2 Nos, DG Neutral- 2 Nos, Office Building - 2 Nos, Quarter Block- 2 No.] |
| 165 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 166 | Extra treatment of soil by using salt & charcoal for pipe electrode as to G.S. |
| 167 | Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 168 | Insulating the 65x8 mm MS flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC (for transformer neutral earth bus bar) |
| 169 | Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. |
| 170 | SUB-HEAD 13:-- SITC of Glowsign Board |
| 171 | SITC of Glowsign Board ( Router cutting) with liquid Acrlyic letters with adhesive on ACP Board of 3 mm Thick (Make – Aludecor / Alstone) of suitable size to accommodate all the matters / contains as approved by the authority to be made with 25 x 25 x 4 mm M.S angle Iron, 18 S.W. G square /Round Hollow bar, Base plate (10 mm Thickness) requires for fixing the necessary Nuts, Bolts, Washers, supporting angle Iron, Clamp etc. and ACP Sheet on Front sides & edges only & back side to be covered by GI Sheet (with proper ventilation arrangement), All side to be moulded uniformly, Side fabricated by Aluminium ‘L’Channel, upon which elevated or box type letter made from imported liquid acrylic will be fixed. The Thickness of Acrylic will be 5 mm (for small letters), 8 mm (for Big letters) and 10 mm (for very big letters). The Back Side of the letters is covered by 3 mm thick ACP (Make – Aludecor / Alstone). The inside of the letter of the letter Supplying and Fixing of best Quality LED Lighting arrangement of fully water proof 10 nos. LED light fittings of 20 watt (100 lumen / watt). The letters are sealed by exterior grade Silicon. The back side of the Board Covered by 22 S.W.G G.I sheet with Nuts & Bolts. (5 no Signage- 24 Sq Ft/ 6 Ft x 4 Ft each) |
| 172 | Intensity: Same & smooth uniform throughout without any dark patch. |
| 173 | Visibility: Up to 250 meters for normal eyes. |
| 174 | The complete sign board would be fixed on roof of the building with providing necessary CC muffing, 1 no CI water proof 200 x 150 x 100 mm loop Box, 50 x 50 x 6 mm MS angel for supporting the board of required length by nuts, bolts, washers etc. After drilling holes on the frame front facia. GSB would have 2 nos. hinge type doors in back side to have the inside access including mending goods the damages to original finish. |
| 175 | Painting of any steel / iron surface of the above Glow sign board with no. of coats of paints as given below with ready mixed paint / primer of approved make and brand incl. preparation of surface by sand paper / emery paper, cleaning etc. for receiving fresh coat of paint. |
| 176 | 1st coat of aluminium paint over one coat of RO priming. |
| 177 | 2nd coat of aluminium paint over one coat of RO priming. |
| 178 | SUB-HEAD 14:-- SITC of AC Machine |
| 179 | Supply of Microprocessor based air cooled ceiling suspended 11 TR capacity Ductable type Split Air Conditioner of rated cooling capacity of 132000 BTU/hr with 1 Nos. ODU Scroll compressor of 3 phase 415V input, (R-32/R-410A/R-407C) Refrigerant,1 nos. IDU of 4400 CFM Air -flow / IDU & wireless remote. (Make-Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas) |
| 180 | Erection & Commissioning Charges for 11 TR Ductable type Split Air Conditioner Indoor and outdoor unit. |
| 181 | Suupply and charging Refrigerant - R-32/R-410A/R-407C. |
| 182 | Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku/Totaline/Jobu) |
| 183 | Suction Line (1 1/8\\" OD with 0.7mm thick) |
| 184 | Liquid Line (5/8\\" OD with 0.6 mm thick) |
| 185 | Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex) |
| 186 | Suction Line (1 1/8\\" OD with 0.7mm thick) |
| 187 | Liquid Line (5/8\\" OD with 0.6 mm thick) |
| 188 | Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex/KEI) |
| 189 | 4 core 4 sq.mm communication cable |
| 190 | Supply and fixing flexible canvass connection for concealed split air-conditioners. |
| 191 | Supply and fixing of Al powder coated continuous Grill (Make- Premier) |
| 192 | DUCT WORK:Supply, installtion, testing and commissioning of Class - VIII grade (120 GSM) supply & return air duct along with necessary supports, flanges etc. as required and as per IS 655 and IS-277 standards of following gauges. |
| 193 | 22 SWG |
| 194 | 24 SWG |
| 195 | Supplying & fixing of 19 mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on new duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete |
| 196 | Supplying & fixing of acoustic insulation inside ducting with 10mm thick open cell nitrile rubber(class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required. |
| 197 | Supply, installation, testing and commissioning of opposed type Duct dampers GI mannual type. |
| 198 | Supply and installation of fusible link Fire Damper .(Make- System Air/premire/Dynacraft). |
| 199 | Supplying, fixing, testing & commissioning of powder coated extruded aluminium section supply air diffuser with M.S volume control dampers as required. (Make-Premire/Dynacraft/Air Master/Caryire) |
| 200 | Supplying, fixing, testing & commissioning of powder coated extruded aluminium section return air diffuser but without volume control dampers as required. (Make-Premire/Dynacraft/Air Master/Caryire) |
| 201 | Supplying, fabrication & fixing of trap door made for maintenance of IDU of Air conditioning system by frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect as per direction of EIC. |
| 202 | supply and installation of 25 mm dia UPVC pipe for condensate dranage water. |
| 203 | Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 8.5/3 TR ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr. |
| 204 | SUB-HEAD 15:- SITC Fire Detection & Alarm System |
| 205 | Supply, Installation,Testing & Commisioning of Micropresssorcontrolled Addressable Multisensor detector ( VDS / UL / LPCB /FM approved ) with inbuilt optical smoke sensors and heat detectorsensor with inbuilt short circuit fault isolator as per NFPA (Note :Detectors without built-in fault isolator is also acceptable with oneindependent short circuit fault isolator after every four (04) detector isto be provided without extra cost) the detectors should have built inresponse indicator with LED indicator. The detector should have 360degree optical view with single / multiple LED that blinks onactuation of detector. Reverse polarity or faulty zone wiring shall notdamage the detectors. Degree of protection as per OEM Standard. |
| 206 | Supply, Installation,Testing & Commisioning of Micropresssorcontrolled Addressable Heat detector ( VDS / UL / LPCB / FMapproved ) with combination of fixed type & Rate of Rise ofTemperature feature. Detector shall have minimum triggeringtemperature programmable from 58 deg. C to 68 deg. C., having highlevel of immunity to electromagnetic influances and show alarm signallimit temperature is reached. Detector shall have inbuilt short circuitfault isolator as per NFPA (Note : Detectors without built-in faultisolator is also acceptable with one independent short circuit faultisolator after every four (04) detector in the loop is to be providedwithout extra cost) the detectors should have built in responseindicator with LED indicator.Degree of protection as per OEMStandard. |
| 207 | Supply, Installation,Testing & Commisioning of Addressable ManualCall Point ( VDS / UL / LPCB / FM approved ) with in built shortcircuit fault isolator as per NFPA (Note : MCP without built-in faultisolator is also acceptable with one independent short circuit faultisolator is to be provided without extra cost). Degree of protection asper OEM Standard. |
| 208 | Supply, Installation, Testing & Commissioning of Addressable LoopPowered /panel powered Hooter (sound output of minimum 90 db )cum strobe (strength of light 10 cd) complete with inbuilt short circuitfault isolator as per NFPA (Note :Hooter without built-in fault isolatoris also acceptable with one independent short circuit fault isolator isto be provided without extra cost). ( VDS / UL / LPCB / FM approved) approved. Degree of protection as per OEM Standard. |
| 209 | Supply, Installation, Testing & Commisioning of Microprocessor basedIntelligent addressable and network connected Repeater OPCcomplied panel ( VDS / UL /ERTL/ LPCB/ FM approved), should haveall the controls and monitoring as on the main fire alarm panel,functioning as a controller, shall allow remote command in the systemreset, trouble and alarm silence and manual alarm. It shall beprogrammable to display information for the entire system i.e. allpanels in the network, having minimum 320 characters LCD display(display system status). The system text displays shall include: Alarmmissing point trouble; system test, service, local system test, extracustom test by polling circuit and address. The repeater panel shouldannunciate alarm and trouble conditions in the occation of signalactuation. Degree of protection as per OEM Standard. |
| 210 | Supply & Laying of 2 Core 1.5 sq.mm FRLSH shielded copper Cable (For Loop) (Make-Finolex/RR Kable/Polycab/Gloster/Gemscab/Havells ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. |
| 211 | SUB-HEAD 16:-- SITC of UPS |
| 212 | SITC of 6 KVA UPS including Battery Bank of 6000 VAH or higher (SMF Battery) 12 Volt single ph Input / single ph Output, inbuilt Isolation Transformer, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 93% efficincy on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low,Static by-pass ON, Over temperature. Battery set Complete with self-standing cubicle or cabinet.The UPS should have external automatic load transfer switch for parallel operation. |
| 213 | Regulated Sealed Lead Acid Battery, Construction type: AGM or VRSLAB in ABS Flame Retardant Rating, 6000 VAH or higher (12V, SMF Battery) (Battery Make Amararaja Quntra/ Exide Power Safe. Back up time30 Min at full load.Warranty : 2(Two) Year on both UPS and SMF Battery on site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/ EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I-2,IEC/ EN 62040-2(EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Powersafe/ Delta) |
| 214 | Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail