| 1 | Cutting road and making good the same i/c supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required of bituminous portion. |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavater) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as we as 10 sqm on plan) including getting out and disposal of exavated earth, lead upto 50 and lift upto 1.5m, as directed by Engineer-in-charge. The contractor has to detect different utilities like sewer line, water supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavating only after getting permission of Engineer-in-Charge. All kinds of soil. |
| 4 | Supply of PVC pipe 10 Kg/cm2 Pressure with required PVC Standard special confirming to IS:4985-2000 with latest amendment Make-Finolex Industries Ltd./Kisan/Superme Industried Ltd. (Rate As Per Comparative Statement Per Rm.)A) 250 mm dia with coupler @ 10 Kg/Cm2 pressure |
| 5 | Supply and installation of required size Steel pipe 8 mm thick conferming to IS:3589 through trenchless excavation of thrust pit and receiving pit of required size and the excavation & filling back and compaction complete as per specification for road crossing by Auger boring method. Pipe will be installed at depth beyond 3.0 m. below the ground surface in downward required slope. 250 mm dia 8 mm thikckness |
| 6 | P/F Sluice Valve shall generally conform to IS 14846 with latest amendment, with length over flanged as per PD of IS 14846 corresponding to BS EN-558 / ISO 5752 Basic series 3 in CI construction having metal seating (IS 318 Gr. LTB 2). With comple component & material of construction following below:-1 - Body / Door / Dome - Cast Iron IS 210 Gr. FC 2602 - Spindle - Non rising: Stainless Steel AISI 4103 - Body seat / Door face - Gun metal : IS 318 Gr. LTB 2 (rings to be press fitted and riveted: no screws allowed)4 - Rivets - Soft annealed brass5 - Spindle Nut - Gun metal : IS 318 Gr. LTB 26 - Stem Seal - Greased Hemp7 - Fasteners - Carbon steel8 - Flange Drilling - IS 1538 Table 4 & 69 - PN 1.010 - Accessories (400 mm and above) - Ball thrust bearings to be housed above the wet chamber ie. above the gland. Enclosed Spur Gear Box for ease of operation. Air Plug11 - Painting / Coating - Inside & Outside epoxy liquid coated; DFT minimum 250 micron, shade RAL 5005 / 5015 (BLUE)12 - Hydro-test-(Open Ended only) (Seat : 10/16 Kg/cm2; Body: 15 / 24 Kg/cm213 - Upto 600mm dia Mannual Operated & above 600mm Gear boxMake-Indian Valve Pvt. Ltd. (IVC) / Kirloskar Brothers Limited KIRLOSKAR) 5.01) 250 mm dia |
| 7 | P/F Reflex Valve upto 600mm dia shall conform to IS 5312 Part-1 & above to IS 5312 Part-2 with latest amendment, Valves shall be in graded CI with metal to metal (IS 318 Gr. LTB 2) seating, preferably slanted (and not perpendicular) vis-a-vis horizontal axis; SS AISI 410 stub pins & slant seat design. with comple component & material of construction following below:-1 - Body / Door / Dome - Cast Iron IS 210 Gr. FC 2602 - Hinge pin (single door) / Stub pin (multidoor type) - SS AISI 4103 - Seat & Face rings - Gun metal : IS 318 Gr. LTB 2 4 - Rivets - Soft annealed brass5 - Fasteners - Carbon steel6 - Flange Drilling - IS 1538 Table 4 & 67 - PN 1.08 - By - pass arrangement - Optional9 - Painting / Coating - Inside & Outside epoxy liquid coated; DFT minimum 250 micron, shade RAL 5005 / 5015 (BLUE)10 - Hydro-test Seat : Seat : 10/16 Kg/cm2; Body: 15 / 24 Kg/cm2Make-Indian Valve Pvt. Ltd. (IVC) / Kirloskar Brothers Limited KIRLOSKAR) 6.01) 250 mm dia |
| 8 | Constructing masonry Chamber inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 10.00A) 120 x 120 x 100 cm |
| 9 | P/F M.S. specials such as Tee, Bend, Collars, Tapers, Gap pieces, including Flange Ends as required, Painting, Cutting, welding as per site requirement of MS pipe thickness etc complete in all respect as per direction of E/I. |
| 10 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : \\"1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : Derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 14 | Hiring of Gas cutting Set With oxygen and LPG Running Time @ 6 Hrs. |
| 15 | Hiring of Welding Set Running Time @ 6 Hrs. |
| 16 | DG Set / Generator 63 KVA |
| 17 | Supply of J.C.B. complete at site on hire basis including cost of diesel and driver etc. complete in all respect as per direction of engineer in-charge |
| 18 | Supply of Tractor with Trolley complete at site on hire basis including cost of diesel and driver etc. complete in all respect as per direction of engineer in-charge |
| 19 | Supply & Fixing KILOSASKAR Make Vertical hollow shaft motor suitable for 400/440 volt 3 Phase 50 Hz A.C. Supply 1440 RPM providing with non reversable rachet to check reverse rotation based on KILOSASKAR MAKE List date…..40 HP / 30 KW |
| 20 | S/F of fully Automatic Control panel with 50 H.P. Auto Transformer for submersible/V.T. Pump sets with following features No-volt, Under-voltage, Over-voltage protection, Microprocessor based overload protection, Unbalancing protection, Winding temperature controller, seal monitor, reverse rotation trip device and the automatic start/stop device according to the levels in the sump. The control panels are provided with normal indications such as Digital voltmeter, Digital Ammeter, and indicating lamps. Above panel is dust and vermin proof made out of 14 SWG CRC sheet with powder coating paint as per directions of E/I. (Make: Contractor-L &T, MCCB-L&T, WTC-Minilec, Auto Transformer-Electracare, VPD & MPD-Softhard, WLC/SM-Pumpcare C.T.-AE, Indicating Light & Push Button- L&T, Control Fuse-EE, Fuse Base-EE, Timer-L&T) |
| 21 | S/F of fully Automatic Control panel with 100 H.P. Auto Transformer for submersible/V.T. Pump sets with following features No-volt, Under-voltage, Over-voltage protection, Microprocessor based overload protection, Unbalancing protection, Winding temperature controller, seal monitor, reverse rotation trip device and the automatic start/stop device according to the levels in the sump. The control panels are provided with normal indications such as Digital voltmeter, Digital Ammeter, and indicating lamps. Above panel is dust and vermin proof made out of 14 SWG CRC sheet with powder coating paint as per directions of E/I. (Make: Contractor-L &T, MCCB-L&T, WTC-Minilec, Auto Transformer-Electracare, VPD & MPD-Softhard, WLC/SM-Pumpcare C.T.-AE, Indicating Light & Push Button- L&T, Control Fuse-EE, Fuse Base-EE, Timer-L&T) |
| 22 | Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, i/c loading, transporting, unloading to approved municipal dumping ground or as approved by E/I, beyond 50 m initial lead, for all leads i/c all lifts involved. (SOR-20, I.No.-15.60) Please Enable Macros to View BoQ information |