| 1 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 2 | White washing with lime to give an even shade including all scaffolding: Old work (two or more coats) including scrapping old surface and repairing with whiting where ever necessary. |
| 3 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment). |
| 4 | Providing & fixing ball bearing for rolling shutters |
| 5 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 6 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concretee block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) |
| 7 | Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes. |
| 8 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 450 mm x 300 mm |
| 9 | Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m Deduct in item no 16 (a) to (d) above if Standard Proctor s density to be achived is at least 90% |
| 10 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Short point (up to 3 mtr.) |
| 11 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Medium point (up to 6 mtr.) |
| 12 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . - 600 mm sweep(700 / 900 RPM) |
| 13 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . - 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 14 | Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR. - 18/20 Watt |
| 15 | SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . - 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM |
| 16 | Supplying and fixing of thermal insulation on exposed roof (underdeck) with 25 mm thick Cross Linked Closed Cell Polyethylene FR-XPE insulation of density 33 Kg/m³ with adhesive etc. as required & finally fixed with the help of rawl plug, dash fasteners & adhesive in ceiling of pieces in size of 900x900 mm or 1200x1200 mm. etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 17 | Supply & Fixing of Water + AFFF 6% Mechanical Foam type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 25 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .- Capacity - 6 Ltrs. |
| 18 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 2 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 6.0 sq.mm |
| 19 | Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:6 |
| 20 | Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materials including curing etc. complete. In cement sand mortar 1:6 |
| 21 | Plaster in cement sand mortar 1:5 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 12mm |
| 22 | Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm |
| 23 | Oil Expeller Machine 6 Bolt Single Gear, Heavy Duty Oil bath and Bearing of Chamber size not less than 24\\" x 4.1/2\\", with V-Belt Pulley and others necessary accessories, Capacity 60 Kg/hr, 7.5 HP, 3 Phase .Extra cloth set 2, dimension (2*5*6) feet with motor and installation ... |
| 24 | Handy Batch Coder Machine |
| 25 | Transportation, Transit Insurance, 3-year warranty after 1 year from installation, 3-year AMC after 1 year from installation , training 2 days ,spare ,tool box etc all connecting piping between tank of ss 304, control panel with wiring from each machine upto supply power point (30m) ... |
| 26 | bottle capping machine hand held |
| 27 | bottle filling machine single nozzle |
| 28 | Hand Pallet Truck with Nylon wheels capacity ; 1.5 Ton min |
| 29 | Electric Bag Stitching Machine with spare needles (12 nos ) and thread box |
| 30 | Name: Solar Basic 10KW – On-Grid Solar Power Plant Description: Specs:PV Panel Make: Reputed Indian MNRE Approved Make Panel: Polycrystalline/Monocrystalline biffacial /topcon Wattage: 540-620 WP(NDCR) Inverter: Standard/Inverter type Inverter Type: On-Grid Inverter Capacity: 10 KW Structure: GI standrad ( height 6 feet)Balance of System: Included AC Cable: Polycab/Reputed – 30 meterDC Cable: Polycab/Reputed – 200 meter ACDB – 1 no IP rating IP65 or IP66 capacity 10KW,Three Phase, Voltage Rating 415V AC, Current rating 32A,UV Protected, Transparent Polycarbonate or ABS Box, AC ; MCB & surge protection device(SPD );A3 Plle ac 40ka Type 2 spd ; terminal blocks Copper Terminal Blocksfor secure AC connections, Cable Glands. All Accessories Included: Lugs, MC4 Connector etc.Earthing copper Electrode – 3 nos; Copper Bonded rods (40 mm dia, 1-2meter),Bentonite Chemical Earthing bag 10 Kg, Nut Bolt with -Washer 1 set, Ring Lug 1 No.Earthing cable– 50 meter, 6 sqmm dia ,conduction material : tinned copper ,insulation material : PVC colour : yellow / green ; spart test KV 6 (AC ) non bvreakdown , Rated temprature 70 dgree rated voltage 450/750 v , DC 1000V ,Europeon cpr : nCcca / Dca / Eca . according tot EN5057 Certificate of TUV / CE ,Construction (AWG)X B35n x mm2, conductor co instruction 494x.3n x2mm , conductor :8.8 mm Resistance max : .536 ohms/km , current carring capacity 218 A Lighthing arrestor : 1 nos , solar copper lighthing arrestor (upto 100 micron copper bonded ), solid rod with 14.2 mm diameter , dimension LXWXH 100X5X5 cm ,lighting arrestor blash plate , item weight 12 kg on GI stand METER / NET METERING -HPL /Equal STANDRAD OTHERS ;: transportation , transit insurance , 3 year warranty after 1 year from installation , 3 year annual maintence contract after 1 year fron installation , training 2 days , spare ,tool box etc ... |
| 31 | SS Storage Tanks – 3 Nos, 200 Ltrs Capacity 3mm thickness on ms stand 1.5 mtrs height |
| 32 | Lab Equipment – Refractometer range 1.32 to 1.53 refractive index 0-100 brix for viscosity and Lab Equipment – moisture meter three scales brix 58.0-92.0% water 13-27% ,baume 38-43 degree ,accuracy brix ± 0.5% / water± 1% / baume ±0.5°, resoulution brix 0.5% /water approximately 1% / Baume ;0.5 degree , Max . Sample temp 90°c length 148 mm ... |
| 33 | Digital Weighing Scale – Capacity 500 Kg with 2 x 2 feet stainless steel platform and digital display ... |
| 34 | Filter Press 12\\" x 12\\" – 12 plates complete with filter brass cocks, 2 sets filter clothes,Tomi bar ,2 Spanners oil collection channel (made of SS 304), bottom dish & strong table made of MS for height of filter press 1.5 hp single phase dimesionions ( 3.4*1.9*3) feet filteration 50-80 liter per hour plus additional pump of VHF 1.0 HP for oil lifting single phase ... |
| 35 | Kachi Ghani with SS Tray & hopper 15–20 Kg/Hr processing with Wooden brackets, Two Units heavy duty gear Box Type single 5.0 HP, 3 Phase dimension (4*8*6 ) feet motor crompton or equivalent . |
| 36 | Plastic Pallets – Flat Top (1000 x 800x125 mm) neelkamal or equilvalent .injection moulded ,static weight 1000kg unified load ,dynamic 500g min material HDPE / PP Weight 13.10kg +/- 3 to 4 % . |
| 37 | Digital Weighing Scale – Capacity 5 Kg with 1x1 feet max , stainless steel platform and digital display , waterproof loadcell along with one each of 1kg , 500 gm and 50 gms, 20 gms and 10 gm standard weight stones. ... Please Enable Macros to View BoQ information |