| 1 | 6.1 Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc.. (Rates are Exclusive of GST) |
| 2 | 6.2 Labour charges for replacement of defective ampere meter /volt meter with new one on existing panel board in pump house./Tubewell/openwell (new voltmeter/ampere meter will be provided by department (Rates are Exclusive of GST) |
| 3 | 6.3.1 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site. (Parts will be supplied by Depatment) (Rates are Exclusive of GST) 5 to 15 HP. |
| 4 | 6.3.2 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) (Rates are Exclusive of GST) 6.3.2 16 to 30 HP. |
| 5 | 6.3.3 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) (Rates are Exclusive of GST) 6.3.3 31 to 60 HP. |
| 6 | 6.3.4 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) (Rates are Exclusive of GST) 6.3.4 61 to 100 HP. |
| 7 | 6.3.5 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) (Rates are Exclusive of GST) 6.3.5 101 to 150 HP. |
| 8 | 6.4.1 Labour charges for repairing of soft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) (Rates are Exclusive of GST) 6.4.1 5 to 15 HP. |
| 9 | 6.4.2 Labour charges for repairing of soft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) (Rates are Exclusive of GST) 6.4.2 16 to 30 HP. |
| 10 | 6.4.3 Labour charges for repairing of soft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) (Rates are Exclusive of GST) 6.4.3 31 to 60 HP. |
| 11 | 6.5 Supply & filling starter oil in oil immersed starters at site. (Rates are Exclusive of GST) |
| 12 | 090700 SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.090710 With Thermal Magnetic release090713 up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu090713.2 Group - 1 |
| 13 | 081700 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081701 Up to 14 Amp081701.2 Group - 1 |
| 14 | 081700 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to 20 Amp081702.2 Group - 1 |
| 15 | 081700 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to 30 Amp081703.2 Group - 1 |
| 16 | 081700 P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to 40 Amp081704.2 Group - 1 |
| 17 | 080600 SF of selector switch of 10 A for voltmeter (4 position ) including making connection etc. as required .080600.2 Group - 1 |
| 18 | 080700 SF of CT linked selector switch of 10 A for Ampere meter (4 position ) including making connection etc. as required .080700.2 Group - 1 |
| 19 | 080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080801 Red/yellow/Green colour080801.2 Group - 1 |
| 20 | 080800 SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.080802 Blue colour080802.3 Group - 2 |
| 21 | 080300 SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.080302 Digital type080302.2 Group - 1 |
| 22 | 080400 SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.080420 Digital type080421 Below 500 A080421.2 Group - 1 |
| 23 | 080500 SF of Current Transformer , with all necessary support in existing panel including connection etc. as required .080501 up to 150 / 5 Ratio , 5 VA , class 1 accuracy080501.2 Group - 1 |
| 24 | 080500 SF of Current Transformer , with all necessary support in existing panel including connection etc. as required .080502 from 200 / 5 to 400/5 Ratio , 10 VA , class 1 accuracy080502.2 Group - 1 |
| 25 | 040112 1 x 4.0 sq.mm040112.2 Group 1 |
| 26 | 040118 1 x 6.0 sq.mm040118.2 Group 1 |
| 27 | 120200 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.120202 2 x 4.0 sq.mm120202.2 Complete Rate |
| 28 | 060111 0.5 A to 5 A rating060111.2 Group 1 |
| 29 | 060112 6 A to 32 A rating060112.3 Group 2 |
| 30 | 060121 6 A to 32 A rating060121.2 Group 1 |
| 31 | 060141 6 A to 32 A rating060141.2 Group 1 |
| 32 | 8.17 Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 8.17.1 up to 6 KVAR |
| 33 | 8.17 Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 8.17.3 KVAR |
| 34 | 8.13 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required. 8.13.1 Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 35 | 4.7 Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 4.7.3 3 core 4.0 Sq.mm |
| 36 | 4.7 Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 4.7.4 3 core 6.0 Sq.mm |
| 37 | 120200 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.120203 2 x 6.0 sq.mm120203.2 Complete Rate |
| 38 | 8.16.1.1 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating - Up to 12 Amp |
| 39 | 8.16.1.2 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating - 16 to 25 Amp |
| 40 | 8.16.1.3 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating - 32 Amp. |
| 41 | 8.16.1.4 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating - 40 Amp |
| 42 | 8.16.1.5 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating - 50 Amp |
| 43 | 8.16.1.6 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 3 pole Power contactors with following AC 3 Rating - 70 Amp Please Enable Macros to View BoQ information |