| Sl. No. | Item Description |
| 1 | Civil works - Excavation in all kinds of soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes ,in accordance with requirements of lines,grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m.work complete as directed by the Engineer-in-charge. (Football field/Athletic track) |
| 2 | Earth work in all kind of soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer-in-charge. (Football field/Public Toilet/Compound wall/Paver road/Drain) |
| 3 | Compound wall (Above 1.5m) |
| 4 | Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. /Public Toilet/Pump room/Compound wall/Paver road) |
| 5 | Construction of granular sub-base by providing Close graded Granular subbase Grading-VI material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (5th Revision) etc complete as per direction of Engineer-in-charge. (Football field/Cricket Pitch/Athletic track/Paver road) |
| 6 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. (Football field/Cricket Pitch/Public toilet/Compound wall/ Drain) |
| 7 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(make-premise-BAYER,Paxton-FMC,ozie-KALYANI) (Football field/Cricket Pitch//Public Toilet) . |
| 8 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. (Cricket Pitch/Public toilet/Pump room/compound wall/Paver road/Drain) |
| 9 | Public Toilet - First Floor |
| 10 | Cement Concrete of proportion (1:2:4) including cost centering and shuttering using 12mm size black hard crusher broken granite chips and screened and washed sharp sand for mortar of approved quality and from approved quarry including the cost of all materials, cost of labour, conveyance, taxes, royalties, loading, unloading, curing, labour cess, T&P, etc. all complete as per the direction of Engineer-in-charge. (Cricket Pitch) |
| 11 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. (Cricket Pitch/Public toilet/compound wall) |
| 12 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. -Ground floor (Gallery/Public toilet/compound wall) |
| 13 | Public Toilet-First floor |
| 14 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. (Gallery/Public Toilet) |
| 15 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.RCC Footing Public toilet/compound wall/Drain) |
| 16 | Grade beam(Public Toilet) |
| 17 | Column & Roof Beam-Ground floor(Public Toilet/Compound wall) |
| 18 | Column & Roof Beam-Upper floor(Gallery/Public Toilet) |
| 19 | Lintel(Public Toilet) |
| 20 | Chajja(Public Toilet) |
| 21 | Shelves(Public Toilet) |
| 22 | RCC wall(Compound wall/Drain) |
| 23 | Roof Slab -Ground floor(Public Toilet) |
| 24 | RCC Slab-Terrace floor(Public Toilet) |
| 25 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.(Public Toilet/Compound wall/Drain) |
| 26 | Providing 12 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. (Public Toilet/Pump room) |
| 27 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.-Ground floor (Gallery/Public Toilet/Pump room/Compound wall) |
| 28 | Gallery- Terrace Floor |
| 29 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground floor(Gallery/Public Toilet/Pump room) |
| 30 | Gallery-Upper floor |
| 31 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Ground Floor(Gallery/Public Toilet/Pump room/Compound wall/Drain) |
| 32 | Terrace Floor |
| 33 | Providing full body matt finish Vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 600x600 of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.(Gallery/Pump room) |
| 34 | Providing and Laying Vitrified Tiles in Dado/Skirting confirming to IS : 15622 of approved make, quality, colour and size 600x600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Gallery/Pump room) |
| 35 | Providing & laying Granite Stone Flooring in Floors and Landing using 20 mm thick Granite Stone Slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Public Toilet) |
| 36 | Providing & laying Granite Stone tiles in Dado/Skirting using 10mm thick Granite Stone Slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) (Public Toiletl) |
| 37 | Rolling & compacting to sub grade or formation loosening by cutting earth for 15cm below the sub grade including watering and compacting in layers by PRR, cost & conveyance of required quantity of water, cost of all labour sundries, T & P etc. required for the work to complete in all respect as per specification and direction of Engineer-in-charge. (Football field/Cricket Pitch/Athletic track) |
| 38 | Painting two coats after filling the surface with Synthetic Enamel Paint in all shades on new plastered concrete surfaces as per section 800 of MoRTH specifications for Road & Bridge works (5th revision) and instruction of Engineer in charge. (Paver Road) |
| 39 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. (Gallery) |
| 40 | Supplying, fitting and fixing of G.I.doors/windows/grill gate made out of square bars, angle, channel, flat, plate, Hollow Pipes, etc painted with red oxide primer cost of all materials, labour, conveyance, taxes, loading, unloading, T&P, etc. all complete. (Cricket field/Public Toilet/Pump room/Compound wall/) |
| 41 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL) (Gallery/Public Toilet/Pump room) |
| 42 | Priming with one coat of water bound cement primer of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge. Ground floor (Gallery/Public Toilet/Pump room/Compound wall) |
| 43 | Upper Floor(Public Toilet) |
| 44 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. (Galley/Public Toilet/Pump room) |
| 45 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). -Ground floor (Gallery/Public Toilet/pump room/Compound wall) |
| 46 | First Floor(Public Toilet) |
| 47 | Painting two coats with plastic emulsion paint of approved quality to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). (Gallery/Public Toilet/Pump room) |
| 48 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge). (Gallery/Public Toilet/Pump room/Compound wall) |
| 49 | Providing and laying 25mm thick grading Concrete of proportion (1:2:2) using 6mm size crusher broken black hard granite chips from approved quarry, scraping and cleaning the surface, fininishing smooth to proper slope and gradient including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, curing,T&P, etc. all complete as per the direction of the engineer-in-charge. (Public Toilet/Galley) |
| 50 | Waterproofing application:- Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 30% Crack Bridging ability : Up to 1 mmAdhesive strength: 1.0 N/mm² @ 28dTensile elongation: 60% @ 20°CShore A Hardness >85 (between 3 - 7 days)etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant)(make-Myk,Fosroc,Sika). Gallery-Ground Floor (Galley) |
| 51 | Providing and laying 1.0 mm thick HDPE/PVC impermeable geotextile membrane below gravel drainage layer, having nil water permeability, minimum tensile strength 15 kN/m, puncture resistance 250 N, laid over prepared sub-base with 300 mm overlaps, jointed and sealed complete in all respects as per direction of Engineer-in-Charge.(Football field) |
| 52 | Supply & laying or brodcosting of Selection - 1 Bermuda Grass in at every 100mm C/C by Ploughing and Levelling, Removal of surplus earth from work site, along with use of necessary fertilizers, pesticides, weedicides, and de weeding with two months maintenance including cost of all materials labour etc. complete. . The rate includes all required fertilizers, pesticides, chemicals, labor, tools, watering, and any other incidental charges for growing the turf, complete as per specifications and directions of Engineer-in-Charge |
| 53 | Supply & spreading of good red earth soil from nearby sources mixed with sand in 2:1 ratio with spreading and levelling the area as per required slope including cost of all materials, transportation etc. complete as per directions of Engineer-in-Charge |
| 54 | Football Goal Post- Supply and installtion of Uprights & Crossbars made from 102mm x 112mm reinforced aluminium with double recess for flush fitting fixings. Reinforced welded aluminium corner joints for improved aesthetics and superior strength, with laser cut internal fixing for exceptionally accurate joints. Injection moulded toughened nylon net clips that won't deteriorate over time. Lock-in T-bar to allow for easy storage of the bottom net bar against upright for pitch maintenance. Reinforced net support system prevents bowing under intense tension. New, heavy duty ratchet winch and webbing strap allows for high-class net shape with the inclusion of a failsafe wire providing 100% security during matches. Lock-in bottom net bar 38mm diameter aluminium bar with ground secure key lock mechanism complete with 4 sockets and whitePolyester powder coated of size 7.32m x 2.44m Set = 2 Goals with 4 x 460mm deep sockets, and net etc. all complete as per FIFA Specification.Make :- Freewill/ harrod/ shelde |
| 55 | Providing and laying in trenches Upvc pipes conforming to IS 4984 1995 and specials of following outside diameter and class-1 to class-3 and jointing including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately)(Football field) |
| 56 | Providing and laying in trenches Upvc pipes conforming to IS 4984 1995 and specials of following outside diameter and class-1 to class-3 and jointing including testing as per specification complete. (Earth work in trenches to be measured and paid fo separately). (Football field) |
| 57 | Supply of non-woven, 150 GSM geotextile fabric, including cutting, placing in trenches, overlapping as required, and securing in position for drainage works as per direction of Engineer-in-Charge. The work includes all labor, tools, and incidental charges complete. |
| 58 | Supply & Erection of Moveable type Circular Section M.S Pipes for Netting Arrangement in Practice Pitches with one coat of red-oxide primer with two layer of synthetic enamel paint including cost of all fabrications, cutting, bending, consumables, Wastage, labour, machinery T&P etc. complete as per directions of Engineer-in Charge. |
| 59 | Providing and laying 4 shaft green coir Cricket Mat Green colour with 8ft cotton canvasA at both end and 72 projected eye lets having thickness 8-10 mm with dual or four core foam etc all complete as per the direction of Engineer-in-charge .The cost inclusive of Transporataion and loading and unloading etc.(Cricket Practice pitch) |
| 60 | Providing & Laying of Clay/Mud Athletic Track including nominal earthwork for ground levelling (2 Inch to 4 Inch), construction of PCC outer toe wall of size 6 Inch width × 1 Foot height, PCC inner side drainage walls on both sides of size 6 Inch width × 1 Foot height, preparation and laying of mud/clay surface with proper dressing, watering, compaction and finishing as per approved specification and drawings including cost of all materials, labour, T&P, conveyance, royalty, taxes, curing and all incidental charges complete in all respect as per direction of Engineer-in-Charge. |
| 61 | Providing & laying specialised Red Clay / Black Cotton Soil from Bolangir with Mixture of Sand With Compaction by VRR including all materials, labour, transportation complete as per the direction of Engineer-In-Charge. |
| 62 | Removing old lime & cement plaster from walls including racking out joints 12mm deep and removing the debris with in 50m lead .(Gallery) |
| 63 | Gallery-First Floor |
| 64 | Dismantling brick or stone masonry in lime or cement mortar above 3.0M height including stacking the usefull materials for reuse and removing the debris within 50 M lead. (Gallery) |
| 65 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead (Gallery) |
| 66 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead.(Gallery) |
| 67 | Dismantling and removing RCC Columns / Beams / Slab including stacking the useful materials for reuse & removing the debris within 50m lead with cost of all labour etc. complete.(Gallery upper floor) |
| 68 | Supplying, fitting & fixing of Well Dressed and Seasoned Sal Wood Choukath of approved size wrought and put up in door frame including two coat of coaltaring to wall and lintel side faces, in all floors including cost, conveyance, taxes of all materials, cost of all labour, labour cess, T&P etc. complete as directed by Engineer-In-Charge.(Gallery) |
| 69 | Supplying and fixing W.I. clamps 33cm to 38Cm long of 35mm × 5mm size for doors, windows and ventilators including fixing in cement concrete (1:3:6) with 12mm, to 20mm hard stone chips or in cement mortar (1:3) including cost of all materials. (Gallery) |
| 70 | Providing and fixing ISI marked 30mm thick Flush Door Shutters conforming to IS : 2202 (Part I) non- decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both facess of shutters including 4 Nos of Stainless steel butt hinges (100mm x 60mm x 2.5mm), 1 No. 6 lever mortice lock with handle, necessary hardware fittings, including the cost, conveyance, taxes of all materials, all labour, T&P etc. complete as per the direction of Engineer-in-charge.(Gallery) |
| 71 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.(Gallery) |
| 72 | Providing & fixing False Ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: (Gallery) |
| 73 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening“for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights complete , as per specifications, drawings and as directed by Engineer-in-Charge.(Gallery) |
| 74 | Expansion Joint :The Expansion Joint Treatment shall be executed in two stages. First stage consist of providing and filling of the expansion joints using two part liquid polysulphide polymer sealant Thioflex 600 having solid content 100%, density 1.60 - 1.65 Kg/ltr, movement capacity: 25% MAF including fixing of backer rod with straight edge finish complete all as specified and as directed. Second stage consist of supplying and installing of Fosroc Expoband one Flexible Polyolefin (FPO) membrane system which is designed to be bonded over expansion and movement joints in structures to prevent the passage of water having Thickness: 1mm, Width: 200mm, Elongation at break : 400% , Tensile Strength : 12.5N/mm2 (DIN EN 12311-2 Method B), Water vapour permeability : 2.7g/Sqm/day (DIN EN 1931-Method B). It is bonded in position using two-part epoxy adhesive, Nitobond PC40 as per manufacturer direction. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, surface preparation, placing baker rod, covering the expansion joint using 2mm thick Aluminium plate fixed by HYSD bolts etc. complete as per design, drawing & instructions of EIC.Make-Fosroc/Myk/Equivalent-(Gallery) |
| 75 | Providing and installation of Impact sports 65 Vinyl Sheet Flooring manufactured by Tarkett with a nominal thickness of 6.5 mm as per EN ISO 24346 and width of 2m as per EN ISO 24341. Impact sports 65 shall conform to EN 14001. The wear surface shall have Top Clean XPT treatment. Impact sports 65 shall have Resistance to wear as ≤1g as per EN ISO 5470-1, Resistance to impacts as per EN 1517 with no degradation, Tested for rolling loads as per EN 1569 and found compliant, Reaction to Fire as per Class Cfl-S1 as per EN 13501-1, tested for Resistance to Indentation and found compliant as per EN 1516 norms, Vertical Deformation value of P1 as per EN 14809, Shock absorption value of P1 as per EN 14808, Friction compliant as per EN 13036-4. The product should provide acoustical improvement of less than or equal to 65 dB - Class A as per EN 16205. The product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measured after 28 days. TVOC and formaldehyde emissions are below 10μg/m3. It is 100% Recyclable with 23% recycled content and 100% REACH compliant.(Gallery) |
| 76 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete.(Gallery) |
| 77 | Supplying and fixing of Wall paneling made of aluminum anodised section framing conforming to standard Aluminium sections as horizontal and vertical members with atleast 600mm c/c and fixing of 9mm thick BWR ply with 4mm thick veneer pasting finished with melamine polishing complete.(Gallery) |
| 78 | Supplying and fixing of Double skin wall panelling made of aluminum anodised section framing conforming to standard Aluminium sections as horizontal and vertical members with atleast 600mm c/c with 9mm thick BWR block ply and 4mm thick veneer finished with melamine polished on both the faces complete.(Gallery) |
| 79 | Providing,fitting and fixing Aluminium Composite Pannel (ACP) of Alstrong Make having 4mm thickness of approved quality & colour coating (0.5 mm coil both side) with PVDF core fixed to RCC column, beams & slabs, Masonry wall etc with necessary brackets, fasteners, bolts,aluminium channel section frame work out of accessories, washers etc and sealed with approved quality sealant between joints of Aluminium pannels of width specified as per design (TREY SYSTEM) etc. complete as per the direction of Engineer-in-charge. (Gallery) |
| 80 | Providing and fixing Structural Glazing with 5 mm thick reflective glass (Approved Make) provided on 1.2 mm thick Aluminium soft frame of section 19 mm x 19 mm fixed on powder coated structural Aluminium frame work made with 2 mm thick section of 100 mm x 48 mm size sealed with silicon sealant etc complete with all labour, cost of all materials and T & P etc. complete as per direction of engineer-in-charge.(Gallery) |
| 81 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer.make-URBAN LIVING VENTURES PVT. LTD./equivalent (Gallery) |
| 82 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.(Paver road) |
| 83 | Supplying and fixing of precast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make ,design,colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. (Paver road) |
| 84 | Filling in Foundation, Plinth and other low laying area with excavated materials including cost of all labour, T&P etc complete including watering and ramming as directed by the Engineer-in-charge .(Public Toilet) |
| 85 | EI Works:-Circuit Cum Wiring-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand(Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group-B |
| 86 | Group-C |
| 87 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 88 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 89 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 90 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 91 | Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole+E-DP plug & socket DB with 32A DP MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge. Make-Legrand/ Siemens/Schneider/ABB |
| 92 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 93 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 94 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 95 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 96 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 97 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 98 | Fan & indoor Fixtures- SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 99 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 100 | Supplying an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 101 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 102 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 103 | Supplying, Erection, Fixing, connection & testing of wall mounted 10W LED Bulkhead wall fitting of Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj. The luminaire should be Replacement Warranty will be 2 years |
| 104 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 105 | Supplying, installation, of heavy duty 400 mm sweep 1400 rpm wall fan(Make- Havells/Crompton/Usha/Orient/Bajaj ) including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 106 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 107 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision)) |
| 108 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 109 | Panels, MDBs, DBs. MCBs-MAIN CONTROL PANEL - Supply, installation, testing and commissioning of LT indoor/outdoor floor-mounted cubicle type Main Control Panel (for lighting and power circuits) fabricated from 3 mm thick CRCA steel sheet, duly derusted and finished with Siemens grey powder-coated paint, designed as per approved G.A. drawing and Engineer-in-Charge directions, complete with 1-year warranty and submission of test certificates, component list, ON/OFF/TRIP indications for all feeders, and 50×10 mm separate aluminium earth busbar, comprising Incomer-1: 1 no. 400A 4P MCCB (Icu=Ics=36 kA) with LSIG microprocessor-based release and electrical interlocking (transformer supply) of make Legrand (DPX3) / Siemens (3VA) / Schneider (CVS), Incomer-2: 1 no. 400A (250–400A adjustable) 4P MCCB (Icu=Ics=36 kA) with LSIG microprocessor-based release and electrical interlocking (DG supply) of make Legrand (DPX3) / Siemens (3VA) / Schneider (CVS), 1 no. 400A on-load changeover switch of make Legrand / ABB / Siemens / Schneider, 4 nos. 600A electrolytic aluminium busbars with color-coded PVC sleeving supported on suitable DMC insulators, outgoing feeders including 2 nos. 250A 4P MCCB (25 kA, TMR release, Icu=Ics) of make Legrand (DPX3) / Siemens (3VA) / Schneider (CVS) / ABB (Formula), 9 nos. 100A 4P MCCB (25 kA, TMR release, Icu=Ics) of make Legrand (DPX3) / Siemens (3VA) / Schneider (CVS) / ABB (Formula), 4 nos. 63A 4P MCB (10 kA, C curve) of make ABB (SB200) / Siemens (Betaguard) / Schneider (Acti 9 AN9) / Legrand (DX3), 3 nos. 40A 4P MCB (10 kA, C curve) of make ABB (SB200) / Siemens (Betaguard) / Schneider (Acti 9 AN9) / Legrand (DX3), complete instrumentation with 6 nos. phase indicating lamps with toggle switches and HRC fuses, digital multifunction meters displaying current, line-to-neutral and line-to-line voltages, frequency, VA and power factor (phase-wise and average) for incomers of make Secure / Legrand, and 2 sets of 4P (3P+N) 65 kA SPD Type 1+2 with 63A 4P MCB (10 kA, C curve) of make Schneider (Acti 9) / Legrand (DX3) / Siemens (Betaguard) / ABB (SB200), complete as required. |
| 110 | 110KVAR APFC Panel- Supply, Installation, Testing & Commissioning of 110 kVAr APFC Panel, LT indoor/outdoor floor-mounted cubical type, fabricated from 3 mm thick CRCA steel sheet, duly derusted and Siemens grey powder-coated, designed as per approved G.A. drawing and direction of Engineer-in-Charge, complete with 400 A Aluminium busbar (25 kA SC, 415 V, 50 Hz, 3-phase), 250 A 25 kA MCCB (Make: ABB Formula/Siemens 3VA/Schneider CVS/Legrand DPX3) incomer with indicating lamps, CTs (250/5 A), digital MFM, 8-step microprocessor-based APFC relay with auto/manual selector, outgoing feeders comprising capacitor banks of 20 kVAr (3 Nos), 15 kVAr (2 Nos), 10 kVAr (1 No), and 5 kVAr (2 Nos) each with suitable TP MCBs (Make: ABB SB200/Siemens Betaguard/Schneider Acti9/Legrand DX3), capacitor duty contactors, 525 V heavy-duty capacitors, 7% detuned harmonic filters with copper-wound reactors, internal wiring, fuses, LED indication, PF display, ON/OFF/TRIP indication, 50×10 mm Aluminium earth busbar, control wiring with lugs, 2 Nos 200 mm heavy-duty exhaust fans, complete protection against over-voltage, voltage unbalance, harmonics, over-temperature with auto-restart facility, complete with test certificates, component list and 1-year warranty, as required for proper operation. |
| 111 | UPS PANEL(O/G)- Supply, Installation, Testing & Commissioning of UPS Outgoing Panel (VTPN MDB), 415 V, 3 Phase, sheet steel double door, indoor/outdoor type, conforming to IEC 61439-3, fabricated with CRCA sheet, 7-tank pre-treated, phosphatized and powder coated, IK09 protection, with integrated door earthing, polyurethane gasket, complete with FR PVC insulated copper wiring up to terminal blocks, tinned copper busbar, neutral busbar, earth bar and DIN rail, including 40 A, 10 kA DP MCB incomer (Make: Legrand Ekinox3/Siemens Betaguard/Schneider Acti9/ABB ITUS) with phase indicating lamps, control fuse/MCB, digital voltmeter and ammeter with selector switch, 40 A, 10 kA Cu SPN busbar, 6 outgoing feeders (1 UPS DB, 2 ELV supply & 3 spares) each with 16–40 A DP, 10 kA MCB (C-curve), complete with all accessories, interconnections, testing, commissioning, 3-year replacement warranty, as per direction of Engineer-in-Charg |
| 112 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years a. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 3 years. |
| 113 | b. 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years. |
| 114 | c. Supply and fixing of 6 way DB single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITH CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD ) Warranty on DB is 3 years. |
| 115 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.. |
| 116 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 117 | Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 118 | Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 119 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 120 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 121 | Floor Ventilation DB(8 Way VTPN DB) Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS with 100A 4P adjustable thermal based MCCB with Ics=100%Icu (16KA)( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) as Incomer, Outgoings-40 to 63A FP MCB 10 KA breaking capacity,C series, (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200) -8Nos.Warranty on DB is 3 years.Warranty on switchgear shall be 1 year. |
| 122 | UPS- Supply, Installation, Testing & Commissioning of 6 KVA Online UPS IGBT based True Online Smart Double conversion efficiency UPS and True Online Double Conversion with DSP Control Technology for High Performance with 3 PHASE I/P & 1 PHASE O/P with Isolation Transformer with Battery Rack with 30 Min Back Up on 90 % Running load along MS Battery KBS Rack & Battery inter connection link with standard make GE/ Emersion-VERTIV/ SIMENSE /ABB/ gutur/ Libert/ APC/Fuji/Aispl or equivalent reputed make catogory accessories for installation with Suitable Battery Bank for 30 minutes with VRL SMF Battery 12 V/26 AHX16 nos for (Exide/Quanta/Aispl Make) & all required accessories to complete the job including all connection. LOAD OF emergency) as per direction of Engg.-in-Charge. Warrenty period of all accessories & component & system mustbe 1 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 123 | CABLE TRAY- Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 124 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 125 | Cables, Cable Laying & Termination- Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. a. 3C X 6 sqmm |
| 126 | b. 4C X 16 sqmm |
| 127 | c. 3.5C X35 sqmm |
| 128 | d. 3.5C X70 sqmm |
| 129 | e. 3.5C X185 sqmm |
| 130 | f. 3.5C X240 sqmm |
| 131 | LAYING OF CABLE- Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand cushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 132 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand cushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 133 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand cushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 134 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface/tray with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 135 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface/tray with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 136 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 137 | TERMINATION OF CABLES - Supply & Making end Termination with brass compression gland and Cu/aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable)a. 3C X 6 sqmm(19 mm) |
| 138 | b. 4C X 16 sqmm(28mm) |
| 139 | c. 3.5C X 35 sq. mm (32mm) |
| 140 | d. 3.5C X 70 sq. mm (38mm) |
| 141 | e. 3.5C X 185 sq. mm (54mm) |
| 142 | f. 3.5C X 240 sq. mm (62mm) |
| 143 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. a. . 200 mm dia (OD-200 mm & ID-176 mm nominal) (for Road crossing) |
| 144 | b. 110 mm dia (OD-110 mm & ID-97 mm nominal) (for external lighting) |
| 145 | Lightning Protection & Earthing- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 146 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 147 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 148 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 149 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IECb 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 150 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 151 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 152 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 153 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 154 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 155 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 156 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 157 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 158 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 159 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 160 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 161 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 162 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 163 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 164 | Earthing System- S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 165 | Providing and fixing 25mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 166 | Supply, Installation, testing & Commissioning of Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 167 | Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground & open surface as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm). |
| 168 | Supplying and laying 6 SWG G.I. wire at existing trench & open surface for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 169 | 250 KVA DG Sets & Other Accessories- DG Set --Supply, Installation, Testing & Commissioning of 250 kVA Silent Diesel Generating Set with prime rating 250 kVA at 0.8 PF under NTP conditions, comprising diesel engine directly coupled with alternator, complete with control panel and all accessories, Make: Jakson Group / Kirloskar Oil Engines / Mahindra Powerol, including self-excited, self-regulated, brushless alternator, 415 V, 3 phase, 50 Hz conforming to IS/IEC 60034-1 with ±1% voltage regulation, IP23 protection, Class-H insulation, complete with 400 A, 4P, 50 kA MCCB and cable termination arrangement; 4-stroke, multi-cylinder, turbocharged, radiator-cooled diesel engine suitable for required BHP at 1500 rpm, with 440 litre daily fuel tank, MS fuel piping, residential silencer, SS flexible exhaust connection, 24V DC starting system with 2×12V batteries and battery charger; common MS channel base frame with anti-vibration mounting; acoustic enclosure made of 14/16 gauge CRCA sheet, modular, powder coated, 7-tank pretreated, with EPDM gasketed doors, lockable handles, attenuators, adequate ventilation, temperature rise limited to 5–7°C above ambient, external emergency stop, and sound level ≤75 dB(A) at 1 m distance, complete in all respects as per specification and direction of Engineer-in-Charge. |
| 170 | Supply of Hand pump to pump the HSD fuel from barrels to the DG tank with flexible hose pipes etc as required. |
| 171 | Metering for DG Set- Supply, installation, testing & commissioning of DG Metering with all accessories as per instruction of EIC.a LTTV 3ph 4wire 3x240V,-/5A,0.5S Class DLMS-C complied static meter with SMC Box with 400/5A LTCT Arrangement |
| 172 | b. 2Core 2.5Sq MM Cu Control Cable (un-armoured) |
| 173 | c. 4Core 2.5Sq MM Cu Control Cable (un-armoured) |
| 174 | d. 75X40X6 MM MS Channel |
| 175 | e. 50X50X6 MM MS Angle |
| 176 | Construction for DG metering foundation (Civil Work).Complete in all respect with instruction of EIC. |
| 177 | Constrution of DG foundation with M-20 Grade RCC(1:1.5:3) of size suitable as per installation of 250 KVA Silent type DG Set with provisioning of 110 PVC piping for Cable laying with all other required accessories as per the direction of Engineering Incharge. |
| 178 | External Lighting- Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 179 | Single Arm Street Lights:- Supply, erection, testing & commissioning of road lighting HDG Octagonal Pole conforming to IS 875 and BS EN ISO 1461 & 410 SP 33 of 7.0 meter with base plate drilling of 1\\" dia hole on the upper portion of the pole for the installtion of street light and 1\\" dia hole on the lower portion of the pole for entry of the wire Base pole paintng of red oxide and two coats of black enamel paint. The poles shall have extra provided and fixed with 4'x2' dia being erected by laying 5'x2'x2' (length, breadth and width) cement concrete block in the ratio 1:3:6 and block be continued up to 1 feet above the ground level i.e 4 feet below ground level including surface plastering the job including excavation of pole with 4 feet deep and refilling the same after installation of the pole and with holes at top of the pole for fixing ring type single armed GI braket for the installation of the integral flood light luminaire of 72 watt. The Dust and wheather proof gasket using for 250mmx200mmx150mm deep box nominal size of 16 SWG thick MS sheet cable looping box with the existing pole with MS clamp made out of 25mmx3mm thick flat iron with suitable nuts and bolts complete with hinged cover and locking screws earth studs neoprene gasket suitable for Nos 4 pole mounted including supply and fixing one no 6 Amp MCB carrier with base and 4 way 60 Amp terminal block suitable to receive PVC armoured cable fixed on suitable size Baketillte sheet base complete connection through GI pipe (classB) 40 mm dia Nominal 1.5 mtr length along the pole or protection of underground cable (on vertical run) with painting all complete as the direction of EIC. Similar to Wipro, Signify (Philips only), LT. |
| 180 | Supply, Installation, Test & Commissioning of 7W LED Decorative Bollard with System light output of 350 lumens. Luminaire shall be made up of dark grey, pure polyester power coated extruded Aluminium housing with seamless milky white polycarbonate diffuser, having dimension of dia(Ø) 100mm± 2mm with height of 800mm±2mm. The housing should be equipped with inbuilt IP67 rated speaker of wattage 5W. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP65 and IK10 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 6500 K, CRI of Minimum 80 and SDCM <5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickness of 35 microns to be used for LED mounting. IP66 rated LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 150-270V AC. Driver Efficiency > 80% & 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 should be there along with suitable Concrete foundation as required. Similar to Wipro model: Whistling Oyster : LED Bollard : LB12 SPK or equivalent of Signify (Philips only), LT. |
| 181 | SITC of Mixture Digital Amplifier of 120 W. Make: Bosch/Honeywell/ Heinrich |
| 182 | Supply, laying, testing & commissioning of 2c x2.5 sqmm Cu Speaker cable with other required arrangements for external uses (laying in existing HDPE pipe separately). Reputed ISI Make |
| 183 | Supply and fixing of Polygonal 25 Meter High Mast System rising lowering type totally hot dip galvanized inside and outside in single dip, suitable for withstanding wind velocity of 200 KMPH.Lantern carraige suitbale to mount 24 - 28 nos light ( 1000 watt ). BASE PLATE:- The base plate should be of Thickness 40mm, consisting of 24 Stifner plate, with 416 J Bolts of size 38 mm and length 1200 mm. The base plate should be confirming to ASTM A 572-50 equivalent with Galvanizing as per BSEN ISO 1461 with all other accessories as per the direction of EIC. Make: Utkarsh, LT, Valmont, Transrail, Vakrangee |
| 184 | Supply & fixing with design of suitable foundation with concrete mix rate M- 35 type foundation for the Stadium mast. The foundation should be designed as per soil testing report and the bearing capacity should not be less than 12.5 T/sq meter. Detailed drawing should be submitted by thetenderer before execution of the work as per design & drawing of OEM for withstanding wind velocity of 200 kmph. High Mast Installation & commissioning Charges including Hydra and also with Civil Foundation. |
| 185 | Supply & fixing of twin dome aviation light having twin type construction with 2 No light of LED type. - (1 Set) and 01 nos lighting arrestors. |
| 186 | SITC of control panel made of FRP/GRP with double door provision and locking arrangement of Tribox (Trinity Touch) or equivalent of any reputed make with IP-55/65 protection for housing of suitable size switch gear consisting of 63A TPN MCB, 10KA (Legrand/ABB/(LK)L&T/Siemens/Schneider /Hager/Havells /Indoasian/C&S/Panasonic make) incomer, single dia timer contactor for the automatic switching of the mast, outgoing terminals |
| 187 | S&F of 1000 watt flood light Make - WIPRO LF46 MODEL OLYMPUS PRO LED SPORTS LIGHT or equivalent of Make: Philips/ LT |
| 188 | Feeder Pillar for External Lights- Supplying installation testing commissioning if double door feeder pillar fabricated out of 3 mm thick CRCA sheet duly painted, 125 Amp Al busbar with neutral bus bar including cc/ brick foundation, Ameter, CT , Voltmeter, Rain Canopy as required including following internal fixtures.1 No - 100 Amp FP , 25 KA MCCB Incomer with suitable contactor and astronomical Analouge Timer / 9 Nos - 16 Amp TPN MCB Outgoing/ 1 No - 16 Amp SP MCB with 6/16 Amp socket outlet with 10 Amp modular switch and 1 No- Bracket Holder with 6 Amp Modular switch. |
| 189 | Supplying and fixing 3 nos GI fire bucket of 9 ltr capacity with suitable pedastal arrangement for sub-station yard etc as reqd. |
| 190 | Supplying 11 kV hand gloves as reqd. |
| 191 | Supplying and Laying Rubber mat 1M X 2M X 2.0MM thick to withstand 1.1 KV dielectric strength, Electrical Safety/Shock Chart & SLD etc as required. |
| 192 | Supply & laying of 11KV Grade best quality Rubber Mat. |
| 193 | Supplying & fixing Route Markers for HT/ LT UG Cable lines. |
| 194 | Providing and fixing LT danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 195 | Supplying of First aid box as approved by St.John Ambulance Brigade/Indian Red Cross Society and confirming to IS 2217/ 1963. |
| 196 | S/F of Shock Treatment chart duly glazed mounted on Aluminum Frame with sheet glass as required. |
| 197 | Providing & fixing of M.S. angle iron with fixing materials and painting for cable racks in trenches/ on walls etc .as required. |
| 198 | Supplying of Caution Boards manufactured out of 16 SWG, MS sheet of 450mmx 300mm size duly painted white and having `MAN ON LINE' and 'DO NOT SWITCH ON' written in Red complete with hanging arrangement as required and & approved by the Engineer Incharge. |
| 199 | Split AC & Other Accessories- 1.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi/Carrier) |
| 200 | REFRIGERANT PIPING- Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 201 | FRAME WORK- Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C |
| 202 | Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe |
| 203 | Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek |
| 204 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 205 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 206 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 207 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP |
| 208 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 209 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 210 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 211 | SITC of OFC Patch Cord, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 212 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 213 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA/STQC compliant. Make-Honeywell(Series 50)/Pelco/ Axis/ BOSCH |
| 214 | Supply , Installation, testing , commissioning of 32 Channel NVR with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).STQC compliant Make-Honeywell series 35/Pelco/Axis/Bosch |
| 215 | Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba |
| 216 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 217 | EXTINGUISHER SYSTEM- Providing and fixing of4.5 kg carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire . |
| 218 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire |
| 219 | Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. |
| 220 | Providing and Fixing of of 2 kG capacity Eco Friendly, Stored pressure type filled with HFC 134 A ( clean agent fire extinguishant having Zero Ozone depletion potential ) Clean Agent Fire Extinguishers with safety seal, pressure guage, controllable discharge mechanism, helium leak detection tested and conforming to IS 15683 complete with initial charge as required.Make-Safex/Fireshield/Ceasefire |
| 221 | P.H Work Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge (Ashirbad/Supreme/Oripalst/Shaakya/AKG)GF Floor -20mm dia C-PVC pipe |
| 222 | 25mm dia C-PVC pipe |
| 223 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Ashirbad/Supreme/Oripalst/Shaakya/AKG)Ground Floor 25mm UPVC ASTM Pipe |
| 224 | 32mm UPVC ASTM Pipe |
| 225 | 1st Floor 40mm UPVC ASTM Pipe |
| 226 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.G. Floor |
| 227 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.G. Floor |
| 228 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in chargeG. Floor |
| 229 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge250mm to 375mm thick wall G. Floor |
| 230 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. 15mm dia long body Bib Cock cock (Jaquar)-CON-CHR-107KN |
| 231 | 15mm dia CP S.B Bib cock (CON-CHR-037KN) |
| 232 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN |
| 233 | 15mm dia CP angle stop cock (FLR-ACR-5053N) |
| 234 | 15mm dia CP SINK cock (Jaquar)FLR-CHR-5347N |
| 235 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 236 | HAND SHOWER (HEALTH FAUCET) WITH 1 METER (Jaquar- ALD-CHR-565 |
| 237 | 15mm dia Two way Bib Cock (Jaquar)-CON-CHR-041KN |
| 238 | Shower Arm (SHA-CHR-477) |
| 239 | Over head shower 100mm dia round (OHS-CHR-1999) |
| 240 | 25mm dia brass or gun metal full way valve(shakti make) |
| 241 | 32mm dia brass or gun metal full way valve(shakti make) |
| 242 | 40mm dia brass or gun metal full way valve(shakti make) |
| 243 | 15mm dia CP Flange |
| 244 | 15mm dia CP Extention Nipple |
| 245 | 125mm CP grating |
| 246 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (Syntax Make) 3 layer on the roof of Ground floor |
| 247 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In (Ashirbad/Supreme/Oripalst/Shaakya/AKG)Ground floor 110mm dia U-PVC SWR pipe |
| 248 | 75 mm dia UPVC SWR Pipe |
| 249 | 110mm U-PVC door tee |
| 250 | 110mm U-PVC Plain tee |
| 251 | 110mm U-PVC door bend |
| 252 | 110mm U-PVC plain bend |
| 253 | 110mm dia U-PVC 'P' trap |
| 254 | 110mm dia U-PVC Plain Shoe Bend |
| 255 | 110mm dia U-PVC offset with out ear |
| 256 | 110mm dia U-PVC cowl |
| 257 | 75 mm dia UPVC plain bend (supreme/ashirvad) |
| 258 | 76 mm dia UPVC plain Tee (supreme/ashirvad) |
| 259 | PVC clamp suitable for 75 mm to 110mm dia pipe |
| 260 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S or P’ trap plain with seat cover(Parryware/Hendware/Cera/Somany/Kerovit) |
| 261 | One piece commod(Hindware)ELEMENT Cat No.92084. |
| 262 | Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan ((Parryware/Hendware/Cera/Somany/Kerovit) |
| 263 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hendware/Cera/Somany/Kerovit) |
| 264 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet) |
| 265 | 15mm dia urinal spreader |
| 266 | 32mm dia C.P. dome waste |
| 267 | Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. Squatting URINAL pan (Parryware/Hinware/Sanituf) |
| 268 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeHalf pedestal Basin(Hindware)No.91049+91115 |
| 269 | Under Counter Basin (560x455) (H)10095 white |
| 270 | 50mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hindware/Cera/Somany/Kerovit) |
| 271 | Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make) |
| 272 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 273 | CP Towel ring |
| 274 | Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge. CP soap holder |
| 275 | Toilet Paper Holder(Jaquar)No.ACN-CHR-1153S |
| 276 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm glass shelf with CP/NP guard rails |
| 277 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in chargeDesign mirror(Parryware) |
| 278 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS RO+UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. Aquaguard 120 PSS RO+UV |
| 279 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etcall complete as per direction of the Engineer in charge. Ground Floor;- |
| 280 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge Ground Floor;- |
| 281 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C. Ground Floor;- |
| 282 | Supplying all materials.labour.T&P and providing brick work with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar(1:4) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. In Ground floor |
| 283 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 284 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 285 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. 0.80 qntl/ cum |
| 286 | Supplying all materials, labour, T&P and fixing Granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In Ground floor |
| 287 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge . Ground Floor;- |
| 288 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size In Ground Floor |
| 289 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 30cm x 60 cm size of Ground Floor;- |
| 290 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 291 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 292 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 293 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 294 | R.C.P.C Cover |
| 295 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 296 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 297 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U-PVC Alround Concrete |
| 298 | 160mm dia U-PVC Alround Concrete |
| 299 | Construction of 50 users RCC septic tank- 2 No Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 300 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. 2x6.10x2.70x1.00 |
| 301 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 302 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 303 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 304 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 305 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height |
| 306 | R.C.C beams,columns,girder and bressmer etc. |
| 307 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 308 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 309 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 310 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 311 | Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In F&P |
| 312 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 313 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 314 | Supplying all materials, labour,T&P and providing 25mm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips on new work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 315 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 316 | Dewatering with 5 H.P diesel engine pump during excavation |
| 317 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee |
| 318 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 319 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 320 | 110mm U-PVC cowl |
| 321 | Construction 1 nos 30 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 322 | - do - with addl. Depth of 1.5 m |
| 323 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge In ground floor |
| 324 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge In ground floor |
| 325 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 326 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge For Roof slab |
| 327 | For RCC wall |
| 328 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 329 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 330 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge 110mm dia UPVC plain Tee |
| 331 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 332 | Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 333 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipe |
| 334 | 110mm dia U-PVC Plain shoe bend |
| 335 | 110mm dia U-PVC Cowl |
| 336 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 337 | Sinking of 150mm dia tubewell through hand boring (water jet ) method (1nos) .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 338 | Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge |
| 339 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres |
| 340 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm dia from 0 to 360 metres |
| 341 | Reaming 150mm to 200mm dia from 0 to 360 metres |
| 342 | Reaming 200 mm to 250mm dia from 0 to 360 metres |
| 343 | Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres |
| 344 | Supplying all labour T&P and grouting with cement slurry for saline sealing in the bore around the 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 345 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres |
| 346 | Cost of 150mm dia PVC ASTM pipe (sch-80) |
| 347 | Cost of 150mm dia PVC cutting slut |
| 348 | Cost of 100 mm dia C.I. cutter plug |
| 349 | Cost of bentonite powder |
| 350 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge |
| 351 | Cost and Conveyance of Gravel |
| 352 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge |
| 353 | Cost and Conveyance of sand |
| 354 | Supplying all labour T&P and grouting with cement slurry for sanitary sealingin the bore around the upper most 3 metres of 150mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 355 | Cost of Cement |
| 356 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor |
| 357 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 358 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.1.5 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm |
| 359 | DOL controll pannel |
| 360 | 2.5 Sqmm flat cable |
| 361 | 32mm dia Steel short piece |
| 362 | Steel roop with cover |
| 363 | Well cap |
| 364 | 50mm size CI bracket |
| 365 | 20mm dia rigid UPVC pipe |
| 366 | 32mm Dia brass non return valve(Shakti make) |
| 367 | 32mm dia HDPE pipe |
| 368 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 369 | Supplying all materials, labour, T&P and providing, fitting and fixing of 5HP Three Phase Drainage Pump motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge5 H.P Open Well Pump Set (Texma Make) |
| 370 | DOL Control panel |
| 371 | 2.50 sqmm flat cable |
| 372 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.40mm brass ball cock with ball Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail