| Sl. No. | Item Description |
| 1 | Providing and laying carpet tiles of style tessera ,construction multi level-loop,fibre Nylon-6,Guage-1/12`, stitches-13 per inch, average pile height-4mm plus - 0.5mm, eco backing I PVC with Fibreglass , tile size-25cmx100 cm, ,commercial,flammability-ASTM E 648 Class I, GB8624-2012 B1c complete |
| 2 | Providing and Installation of Baffle ceiling / Open Cell Ceiling system comprises of 50 mm x 100 mm (50 mm width and 100 mm Height) U Shape panels in RAL color finish( in case of baffle ceiling). Panels shall be made of 0.5 mm thick galvanized steel after Powder-coated and length up to 4000 mm. Panel shall be high corrosion resistance and good color stability. Centre to Centre panel gap will be 150 mm. Panels are fixed on to roll formed carriers 20 mm wide x 40 mm deep out of 0.80 mm G.I sheet Powder-coated color with cutouts to hold the panels in module of 50 mm at maximum 1200 m c/c. Carriers are suspended from the roof or truss by 6 mm dia. galvanized steel wire rod hanger with special height adjustment suspension clip at max. 1200 mm c/c. Hangers are fixed to the roof by โJโ hooks or ceiling brackets and nylon inserts. Panels are factory cut in lengths up to maximum 4.0 m to suit site dimensions or shop drawings. Top cap and side cap are used to cover the edges of the panels. |
| 3 | WALLPAPER : Providing and Fixing Vinyl Coated Wall covering as per approved make and pattern as approved by the client and architect. |
| 4 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Providing and Fixing door handle set with lock body and cylinder for main doors and internal doors Made from high-grade zinc alloy with satin steel finish with 5-Pin cylinder mechanism with both side cylinder made of superior corrosion free brass, includes 2 No. Door Handles, 1 No. Striker Plate, Keys, Lock Body all complete |
| 6 | MDF Board 4mm thk fixed with nails complete in all respect |
| 7 | Providing and Fixing of PVC Wall Panelling complete in all respect to the entire satisfaction of engineer in charge |
| 8 | 50MM THICK GI FRAME (FOR THICK PARTITION) for MDF : Providing and fixing metal system up to ceiling height, which includes frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 GSM, consisting of Boral U track 52mm wide having equal flanges of 30mm and 0.55mm thick (Base metal thickness) fastened to the floor slab and ceiling soffit using rawl plugs with screw at 600mm centers, with first and last fixing point at not greater than 50 mm from either end. Boral C studs 50mm wide having one flange of 34mm, other flange 36mm, lip size 6 mm and 0.55mm thick installed perpendicularly within the flanges of floor and ceiling channels located directly opposite to each other at not more than 610mm centers. Maintain 5 to 10mm gap between C Stud and web of U Track |
| 9 | Providing and fixing zebra blinds on windows complete. |
| 10 | WPC WALL PANELLING : Providing and Fixing WPC Wall panelling as per approved make and pattern as approved by the client and architect. |
| 11 | Melamine Polish: Applying one coat of lacquer/primer followed by one or two coat of colour polish to give desired shade and two to three coats of melamine sealer to give final shade including the coats of wood healer and sanding the surface wherever required al complete. |
| 12 | PandF horizontal wooden roller blinds on windows complete with material and labour complete with push up and down arrangements as per approved design/color and engineer-incharge. |
| 13 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 88m Head |
| 14 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.`Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.`M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.2280 lpm at 88 m Head |
| 15 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS : 325.M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.180pm at 88 m Head |
| 16 | `Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizescomplete as required.`150 mm. dia |
| 17 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .25 mm dia |
| 18 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .32mm dia |
| 19 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .40 mm dia |
| 20 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .50 mm dia |
| 21 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .65 mm dia |
| 22 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .80 mm dia |
| 23 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .100 mm dia |
| 24 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .150mm dia |
| 25 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .200 mm dia ( Wall thickness 6.3 mm ) |
| 26 | Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to IS : 1239 / 3589 including Fittings like elbows , tees , flanges , tapers , nuts , bolts , gaskets etc in ground including welding excavation and Providing cement concrete blocks as supports anticorrosive treatment with coaltar / asphalts tape as per IS :10221 refilling the trench etc of following sizes complete as required .250 mm dia ( Wall thickness 6.3 mm ) |
| 27 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 28 | Supplying Fixing Testing and Commissioning of butterfly valve of PN 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts , bolts , washers , gaskets conforming to IS : 13095 of following sizes as required .80mm dia |
| 29 | Supplying Fixing Testing and Commissioning of butterfly valve of PN 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts , bolts , washers , gaskets conforming to IS : 13095 of following sizes as required .100mm dia |
| 30 | Supplying Fixing Testing and Commissioning of butterfly valve of PN 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts , bolts , washers , gaskets conforming to IS : 13095 of following sizes as required .150 mm dia |
| 31 | Supplying Fixing Testing and Commissioning of butterfly valve of PN 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts , bolts , washers , gaskets conforming to IS : 13095 of following sizes as required .200 mm dia |
| 32 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 33 | Providing Installation Testing and Commissioning of Non Return Valve of following sizes conforming to IS : 5312 complete with rubber gasket , GI Bolts , Nuts , washers etc as required . 80mm dia |
| 34 | Providing Installation Testing and Commissioning of Non Return Valve of following sizes conforming to IS : 5312 complete with rubber gasket , GI Bolts , Nuts , washers etc as required . 100 mm dia |
| 35 | Providing Installation Testing and Commissioning of Non Return Valve of following sizes conforming to IS : 5312 complete with rubber gasket , GI Bolts , Nuts , washers etc as required . 150 mm dia |
| 36 | Providing Installation Testing and Commissioning of Stainless Steel Y Strainer fabricated out of 1.6 mm thick stainless steel , Grade 304 , Sheet with 3 mm dia holes with stainless steel flange . 150 mm dia |
| 37 | Providing Installation Testing and Commissioning of Stainless Steel Y Strainer fabricated out of 1.6 mm thick stainless steel , Grade 304 , Sheet with 3 mm dia holes with stainless steel flange . 200 mm dia |
| 38 | `Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636(type-A) as required :`Gun Metal |
| 39 | Supplying and Fixing First aid hose reel with MS Construction Spray painted in Post office red conforming to IS : 884 complete with the following as required 20 mm nominal internal dia water hose thermoplastic ( Textile Reinforced ) Type - 2 as per IS : 12585 20 mm nominal internal dia gunmetal globe valve and nozzle Drum and Brackets for fixing the equipments on wall Connections from Riser with 25 mm dia stop gunmetal valve and MS Pipe and socket 40 Metre Length |
| 40 | Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Gun metal |
| 41 | Supplying and Fixing of Fire brigade connection of Cast iron body with gunmetal male intantaneous inlet coupling complete with cap and chain as required for suitable dia ms pipe connection conforming to IS : 904 as required 2 Way - 100 mm dia MS Pipe |
| 42 | Supplying and Fixing of Fire brigade connection of Cast iron body with gunmetal male intantaneous inlet coupling complete with cap and chain as required for suitable dia ms pipe connection conforming to IS : 904 as required 4 Way - 150 mm dia MS Pipe |
| 43 | Supplying and Fixing Air Vessel made of 250 mm dia 8 mm thick ms sheet 1200 mm in height with air release valve on top and flanged connection to riser drain arrangement with 25 mm dia gunmetal wheel valve with required accessories pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 44 | Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler |
| 45 | Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :upright |
| 46 | Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Horizontal side wall Sprinkler |
| 47 | Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 48 | Providing and fixing flow switch in following sizes M.S. pipe including connection etc as required.150mm dia |
| 49 | DSR 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14.1 2 X 1.5 sq. mm plus 1 X 1.5 sq. mm earth wire |
| 50 | Providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :150mm dia |
| 51 | DSR 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14.2 2 X 2.5 sq. mm plus 1 X 2.5 sq. mm earth wire |
| 52 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14.3 2 X 4 sq. mm plus 1 X 4 sq. mm earth wire |
| 53 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14.4 2 X 6 sq. mm plus 1 X 6 sq. mm earth wire |
| 54 | Providing and fixing dial type pressure gauge with isolation cock and copper pipe on main header Dial diameter 100 mm celebration 0-16 / sq. cm. |
| 55 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14.5 2 x 10 sq. mm plus 1 x 6 sq.mm earth wire |
| 56 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14.10 4 X 10 sq. mm plus 2 X 6 sq. mm earth wire |
| 57 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14.11 4 X 16 sq. mm plus 2 X 6 sq. mm earth wire |
| 58 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal |
| 59 | DSR-1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 60 | DSR-1.57 Supplying and fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, โCโ curve including connection, painting etc. as required. (AC`s and Gysers) |
| 61 | Supply Installation,Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, micro processor based Controller,top discharge type condensing unit(s), with R410A Refrigerant,vibration isolators,with suitable foundation etc. complete as required.The unit shall deliver the rated capacity at AHRI Conditions and work even at 50ยฐC ambient temperature without tripping.The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50HzAC power supply.The unit shall be filled with first charge of the refrigerant and ready for use as required.The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.(Considering conversion factor IHP= 0.83TR)Unit Per HP |
| 62 | Supply, installation ,testing and commissioning of following minimum capacity 4-wayflow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter , fan section with low noise fan /dynamically balanced blower ,multi speed motor, coil section with DX Copper coil,electronic expansion valve,outer cabinet,drain pump,grill ,necessary supports ,vibration isolation, cordless remote control etc.,suitable for operation on singlephase 230Vยฑ10%, 50HzAC supply, complete, as required.The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will beat air inlet conditions of 27DegreeCDBand19DegreeCWB temperature.1.5 TR |
| 63 | Supply, installation ,testing and commissioning of following minimum capacity 4-wayflow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter , fan section with low noise fan /dynamically balanced blower ,multi speed motor, coil section with DX Copper coil,electronic expansion valve,outer cabinet,drain pump,grill ,necessary supports ,vibration isolation, cordless remote control etc.,suitable for operation on singlephase 230Vยฑ10%, 50HzAC supply, complete, as required.The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will beat air inlet conditions of 27DegreeCDBand19DegreeCWB temperature.2 TR |
| 64 | Supply, installation ,testing and commissioning of following minimum capacity 4-wayflow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter , fan section with low noise fan /dynamically balanced blower ,multi speed motor, coil section with DX Copper coil,electronic expansion valve,outer cabinet,drain pump,grill ,necessary supports ,vibration isolation, cordless remote control etc.,suitable for operation on singlephase 230Vยฑ10%, 50HzAC supply, complete, as required.The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will beat air inlet conditions of 27DegreeCDBand19DegreeCWB temperature. 3.2 TR |
| 65 | Supply, installation ,testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower ,multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet ,cordless remote control , drainpan , necessary accessories etc.,suitable for operationon 230Vยฑ10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic forceshut down provisionin case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.65 TR |
| 66 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia ID |
| 67 | Providing and fixing Stainless steel satin finish SS 304 grade 6` LONG Handles with SS screws for wooden doors of approved make and model all complete as per the directions of Engineer-in-charge |
| 68 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 69 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 70 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 71 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 72 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 73 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 74 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 75 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 76 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required 41.3 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation |
| 77 | Supply, installation, balancing and commissioning of Factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.0.80 MM (22 gauge) Galvanized Sheet Steel Ducting |
| 78 | Supply, installation, balancing and commissioning of Factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.0.63 MM (24 gauge) Galvanized Sheet Steel Ducting |
| 79 | Supply, installation, balancing and commissioning of Factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.1.0 MM (20 gauge) Galvanized Sheet Steel Ducting |
| 80 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.0.63 MM (24 gauge) Galvanized Sheet Steel Ducting |
| 81 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.0.80 MM (22 gauge) Galvanized Sheet Steel Ducting |
| 82 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.1.0 MM (20 gauge) Galvanized Sheet Steel Ducting |
| 83 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. |
| 84 | Supplying and fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
| 85 | Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications. |
| 86 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core. |
| 87 | Supplying, fixing testing commissioning of Return air/ Exhaust diffusers of powder coated aluminium without volume control dampers with anti smudge ring and removable core. |
| 88 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper |
| 89 | Supplying, fixing acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 Kg/M3, with 25 mm x 25 mm GI section of 1.25 mm thick at 600 mm centre to centre covering with rienforced plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound complete as required and as per specification. |
| 90 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (classโOโ) insulation on existing duct after applying Suitable adhesive for nitrile rubber. The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.19 mm thick (In Condition Space) |
| 91 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 92 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 93 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`4 X 10 sq. mm (28mm) |
| 94 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`4 X 16 sq. mm (28mm) |
| 95 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 25 sq. mm (28mm) |
| 96 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 35 sq. mm (32mm) |
| 97 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 50 sq. mm (35mm) |
| 98 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 70 sq. mm (38mm) |
| 99 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 95 sq. mm (45mm) |
| 100 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 120 sq. mm (45mm) |
| 101 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 150 sq. mm (50mm) |
| 102 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 185 sq. mm (57mm) |
| 103 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 240 sq. mm (62mm) |
| 104 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`3ยฝ X 300 sq. mm (70mm) |
| 105 | ALUMINIUM SKIRTING : Supply of 100 mm `DMC` Aluminium (Grade 6063) Skirting with 15 micron anodising In Natural Finish. Thichness 1.30 to 1.50 mm. Designed to conceal screws. Seamless finish. Complete with Rubber/ PVC Jointers and Gasket. |
| 106 | Supply of LED Lights behind the Fabric Wall/False ceiling in noddes/PCB with rece nmended wattage as per manufactura`s standards to gve an effect ofambicnt lighting LED make MLS/ Bridgelux /Osram- SMD 2835, LED spacing/Pitch should be aticast 73-80mm with beam anele of 170 degree. Colour temperature shoud be as per design intent 3000K/4000K/6000K Wattage of 8-10W/mr. LED modules/PCB sbould be positioned properly to pronde an cven ight low, casting noshadows or dark spots. LED Driver Cost included. |
| 107 | Supply andinstallation of fabric false cciling/wsll formed out with NAKSHATRA CLIPSO TRANSLUCENT Printed fabric coverings made out of polyester knitted fabric costed with Polyurethane (PU). The NAKSHATRA CLIPSO TRANSLUCENT Printed fabric width of 2m, 3m. 4.lm and5.Im with weight of 200gm/m2, thickness of 0, 3 mm. The appcarance of fabric is malt, smooth and uniform with blanq color and light transmission of 50%. The tear strength of fabric should be accordance to CH: 4,5daN, TR: 6,5 daN. The fire rating should bc accordance to B-S1, d0. The fabric should be huznidity resistant and free of carcinogenic substancesCMR) or volarile organic Compounds (VOC`s) At labeling in acydance with the French decree no. 2011-321, Ocko-Tex standard100 cetified Fabric should be installed with approved nenufacturer guidelines. It comes with 10- year manufacturer guarantee. The installation of NAKSHATRA CLIPSO TRANSLUCENT Printed fabric should be dry installation and done at room lemperature sing CLIPSO PVC. ABS Grppers. Clipso ceiling base to be made of MS or Wooden frame finishing to a lush finish of tapered and square edges in desired design as per archtect specilication, LED Fittings included in the Item. |
| 108 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray cross members with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 109 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray cross members with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 110 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray cross members with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 111 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee`s with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 112 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee`s with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 113 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee`s with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 114 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 115 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 116 | Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness |
| 117 | `Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ยฑ 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as perspecifications.10 loop panel |
| 118 | DSR 17.2.3 Supplying, installation, testing and commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 119 | DSR 17.2.5 Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required. |
| 120 | DSR 17.2.7 Supplying, installation, testing and commissioning of fault isolator complete with base as required. |
| 121 | DSR 17.2.10 Supplying, installation, testing and commissioning of addressable fire control module complete as required. |
| 122 | DSR 17.2.9 Supplying, installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 123 | DSR 17.2.15 Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required. |
| 124 | DSR 17.2.14 Supplying, installation, testing and commissioning of addressable manual call point complete as required. |
| 125 | DSR 17.2.17 Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required. |
| 126 | DSR 17.2.19 Supplying, installation, testing and commissioning of fire fighter phone jack complete as required. |
| 127 | DSR 17.3.2 Supplying, installation, testing and commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 128 | DSR 17.3.2 Supplying, installation, testing and commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 129 | DSR 17.3.7 Supplying, installation, testing and commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 130 | DSR 1.53.1 Supplying and drawing of UTP 4 pair CAT6 LAN cable in the existing surface /recessed steel /PVC conduit as required (1 run of cable). |
| 131 | DSR 17.5.2 Supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring and FRLS outer sheath complete as required. |
| 132 | DSR 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.DSR 1.17.2 2 x 1.5 sq. mm |
| 133 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.300 mm dia ID |
| 134 | CONTROL PANELS`Fabrication, supply, Insallation testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specificationwith following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :`INCOMING`400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switchDigital Ammeter (0-400 A) with selector swtich and CTs etc.`LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 500AOUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.-2 setJockey Pump100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.-2 setDIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch and 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System System control Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 135 | `Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.`4 X 6 sq. mm (28mm)i/c gst |
| 136 | Providing and fixing weather proof Fire Hose Cabinet of size not less than 0.75 x 0.6 x 0.25 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside `with the letters `FIRE HOSE` including necessary locking arrangement and painting in PO red colour suitable to accommodate, external yard hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire man`s axe. It shall be mounted on boundary wall complete |
| 137 | PandF Fire Hose Cabinet size not less than 2.1 x 1.2 x 0.90 mtr made out of M.S. sheet not less than 1.5 mm thick havingcentral opening and 4 mm thick glazed glass doors (Two nos.) ` |
| 138 | Providing and fixing double flanged flexicon rubber expansion joint with unit control of standard length as per maufacturers specs. Tested to a pressure of 20 Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.80mm dia |
| 139 | Providing and fixing double flanged flexicon rubber expansion joint with unit control of standard length as per maufacturers specs. Tested to a pressure of 20 Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.100mm dia |
| 140 | Providing and fixing double flanged flexicon rubber expansion joint with unit control of standard length as per maufacturers specs. Tested to a pressure of 20 Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.150mm |
| 141 | Providing and fixing double flanged flexicon rubber expansion joint with unit control of standard length as per maufacturers specs. Tested to a pressure of 20 Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.200mm dia |
| 142 | Providing and fixing Fire Extinguishers (CO2 type powder ) 4.5 Kg Capacity complete with all accessories as per manufacturers specifications.(Updated) |
| 143 | Providing and fixing Fire Extinguishers (A, B, C type powder ) 9 Kg Capacity complete with all accessories as per manufacturers specifications. |
| 144 | Providing and fixing GM fire Brigade Suction hose coupling (Draw out Connection) with nut for female coupling as per IS:902-1974 complete with 100mm dia. 1 No C.I Foot valve flanged (to be connected to static water tank). |
| 145 | Providing and fixing Stainless steel satin finish SS 304 grade Tower Bolts SS screws for wooden doors of approved make and model all complete as per the directions of Engineer-in-charge250x10 mm. |
| 146 | Providing and fixing Stainless steel satin finish SS 304 grade Tower Bolts SS screws for wooden doors of approved make and model all complete as per the directions of Engineer-in-charge100x10 mm. |
| 147 | Providing and Installation of Funder Max / ALSTRONG for cladding on exterior pergolas 9mm thick Exterior grade F- Quality panels of standard size with both side dรฉcor . The Panels shall be perforated as per the design of the Architect. FunderMax / ALSTRONG Exterior panels are duromer high-pressure laminates (HPL) as per EN 438-6 type EDF manufactured with norm conformity of EN 438-7 using patented NT Technology (NT is Non fading high performance acrylic polyurethane surface Technology). Panels will be double hardened including acrylic polyurethane resin and thermally cured under high pressure.These Panels will have CE-Mark necessary for their use in building applications. Installation of FunderMax panels will be done by MBE Rivets (with Fixed and Sliding Points) with recommended Aluminum T section of 100x50x2 mm thick and L section 50x50x2mm thick held by Aluminum Wall Bracket with Wind load and Dead load slot as per design, anchored by standard anchor fasteners along with Thermal Separator. Installation of FunderMax Panels will be done using Rear Ventilated Principles only, which is ensured by providing ventilation gap minimum 200 cm2/ per Meter (for free flow of air behind the faรงade) for the faรงade and using the framework with no horizontal section. |
| 148 | `Supply and fixing approved Slim floor tile 3000mm x 1000mm Porcelain sheet having 3.5mm thickness with mesh on cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. Suitable for internal and external facade with matt and slip resistant finishes weighing 21kg. Shade and installation process shall be as directed by Engineer in charge. Material shal confirm to BS EN 14411G. Slab shall include the surface hardness (UNE EN ISO 67-101) of 7 MOH scale, Stain resistance at class 5 (stains could be easily clean by hot water), Water absorption 0.4%, Resistance to chemical attack, Smog resistant, Froast resistance, Resistance to thermal shock and bacteria, Fire Resistance (A1 Class). ECO Friendly certification under GREEN GUARD CERTIFICATION from US Green Building Council and UV protected all complete as per drawing and as directed by Engineer-in-chargeRates shall include cost of all items listed above at all heights and levels including hardware etc as per drawings and as directed by the Engineer-in-charge |
| 149 | `Supply and fixing approved Slim wall tile 3000mm x 1000mm Porcelain sheet having 3.5mm thickness with mesh on cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. Suitable for internal and external facade with matt and slip resistant finishes weighing 21kg. Shade and installation process shall be as directed by Engineer in charge. Material shal confirm to BS EN 14411G. Slab shall include the surface hardness (UNE EN ISO 67-101) of 7 MOH scale, Stain resistance at class 5 (stains could be easily clean by hot water), Water absorption 0.4%, Resistance to chemical attack, Smog resistant, Froast resistance, Resistance to thermal shock and bacteria, Fire Resistance (A1 Class). ECO Friendly certification under GREEN GUARD CERTIFICATION from US Green Building Council and UV protected all complete as per drawing and as directed by Engineer-in-chargeRates shall include cost of all items listed above at all heights and levels including hardware etc as per drawings and as directed by the Engineer-in-charge |
| 150 | Providing and laying floor tiles in size 122x247mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete |
| 151 | Providing and laying Wall tiles in size 122x247mm with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete |
| 152 | Providing and fixing Engineered wooden flooring Panel 1820 x 145 Total thickness 14 mm Numbers of panels per pack 6 Nested Lengths Max. 1 plank out of 6 m2 per pack 1,583 m2 Kg per pack 11,99 kg Toplayer PEFC controlled sources EN 13489 ยฑ 3 mm Core board PEFC controlled sources Spruce Backing layer PEFC controlled sources Wood Veneer 2 mm Tongue and groove Length Uniclic Width Uniclic Multifit Domestic use Conditions in each pack 33 years Uniclic - Multifit connection Lifetime Commercial On request `Wood for Life` Edge Protect plus Provides a warranty on build-up of residue dirt along the edges due to maintenance over the years 10 years `Wood for Life` Surface and Edge Protect plus (lacquered products only) Provides a warranty on pollution of surface structure and a warranty on build-up residue dirt along the edges due to maintenance over the years 10 years Surface layer Wood species Oak Origin Europe Finishing UV cured Oiled finish 2 layers UV cured Lacquer Anti-scratch top coat 5 - 7 layers Natural variance Due to nature, visual surface can deviate from samples Surface treatments cf catalogue/website Nature Marquant Vibrant General aspect of installed EN 13489 Lipping - difference in height (mm) = 0,20 difference in width (mm) = 0,20 cupping lengthwise % = 0,1 cupping in width % = 0,2 Dimensional stability ISO 24339 Cupping short side max % = 0,30 Changes 30 - 85 % RH Cupping short side min % = - 0,20 Open joints short side (mm) = 0,20 Open joints long side (mm) = 0,30 Underfloor heating Suitable of special installation instructions |
| 153 | `Providing and laying Floor Architecture Collection- Poured tiles of Yarn type Eco Solution Qยฎ Nylon ( Nylon 6 ) only: Multi-Level Pattern Loop, manufactured using solution dyeing process, Tiles of size 61 cms x 61 cms with Shaw Soil and stain resistance protective treatment โข or equivalent containing properties of Stain Repel, Stain resist and Stain Release , Anti , with Ecoworxยฎ Tile- 100% PVC Free / 100% Bitumen Free/ 100% Recyclable - backing system with recycled content, made from thermoplastic polyolefin compound with reinforcing layer high performance environments requiring modular flooring , having tufted yarn weight of 542.5 gsm and average yarn density of 7385 oz/cu. yd. or more, Nominal total thickness 5.79 mm minimum, Radiant Panel class1rated ( ASTM E648) ,NBS smoke ( 450, Pill test -Passed, Texture Appearance Retention Rating of 3.5 for Severe Use, Anti Microbial Treatment-Passes (AATCC-174). CRI Green Label Plus certified for indoor air quality, including fixing/ installation with Low/ Zero VOC content Adhesive. Impact Sound (ISO 10140-3) 20 dB and Sound absorption (ISO 354) 0.2 Class D.Manufacturer to submit Test Report / Certificate stating meeting CRI`s - Severe Use Rating and Acoustic properties and complying to specification is mandatory. All Certificates to be provided before release or award of Contract |
| 154 | Providing and fixing of 6 mm thick premium GRIHA rated Lacquered glass of approved color by Architect/ Client / Customer, fixed with compatible neutral grade silicon on a perfectly levelled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on RCC wall/any other structure. Lacquered glass must be made industrially (using curtain coating process): opaque (if viewed against a support wall), uniformly coated with PU lacquer (50 micron thick coating or more): panel to panel colour consistency (measured by photo spectrometer): highly durable (passes hardness test for minimum 220 oscillations): humidity resistance (conforms to BS EN 1036 1999 or equivalent) : environmentally friendly having Low VOC (no lead, no arsenic, no copper, no formaldehyde), low VOC content (100g/l. Silicone used should not react with lacquer coating (compatible neutral cure silicon ) |
| 155 | Providing and fixing of panels - 1200mm*2400mm *20mm thickness, NRC = 0.90, Resistance to fire : REI 90 made out of mineral fibre. Panels to be fixed on framework made out GI ( 0.60mm thick and 60 MM Width ) sections to form a section of 600mm x 600mm. Panels to be fixed on the Slabs with a minimum of 50mm to 100mm void or gap with Galvanized screws of length 50 mm and Dia 4.5 mm.In case of islands - vertical shall be provided with metal section all 4 sides. In case of wall to wall, wall angle shall be provided towards the wall or UD section shall be provided which shall be concealled as per the architects design |
| 156 | Providing and fixing GI Plain 75mm wide x15mm deep panel upto 6mtr, shall be roll formed out of 0.5mm thick Powder Coated .The top coat of panel shall be 60 micron polyester coated finish in approved colour. The panel shall be factory cut in up to 6Mtr OR required length. Accessories Detail: Carrier: 63mm deep, made out of 0.6mm thick steel backed with enameled black paint having cut out to hold on panel in a module of 75mm closed. The joint of two carriers shall be joined by means of carrier splices maintaining a module of 75mm .4mm dia galvanized rod with special height adjustment butter fly clips made out of SS steel sheet. The edge profile G.I.shall be matching with the panel |
| 157 | `Finishing walls with graite atelio exterior paint of required shade: Natural granite-based finish. Modified pure acrylic emulsion based, reinforced by Granite aggregate. Formulated to withstand humidity, rain and hot climate. It Contains silicone additive for breathability and water resistance. It contains anti-fungal and antibacterial additives.`Granite is one of the most durable stones used in artistic and architectural applications, including outdoor sculpture. Granite has 7 Hardness on Mohs Hardness scale. Granite is defined by the American Society for Testing and Materials (ASTM) as a `visibly granular, igneous rock generally ranging in color from pink to light or dark grey, and consisting mostly of quartz and feldspars, accompanied by one or more dark minerals`.Marble and limestone, granite is not an acid soluble stone and is much more resistant to the effects of acidic solutions, rainwater or cleansing agents. In general, igneous building stones, such as granite, have a more inert composition: show much lower rates of deterioration: have lower water absorption, and are harder than marbles, lime stones and sandstones |
| 158 | ALUMINIUM LOUVERSupply and Installation of Green Pro Certified Luxalon Aeroscreen 450 perforated and Roll-formed Louver Fixed Vertical System consists of aluminium extrusion with a wall thickness of min 1.8 mm fin and a 0.7-0.9 mm thickness preformed Aluminium skin made up of alloy AA 3105 Series,H14 / H44 with Fixing accessories of Sliding U โ Profile, Fixation Disk, Fin Suspension and end caps for fixed system. The Aeroscreen System should have roll-formed and perforated fins. Aeroscreen Single Skin has perforation with 2.4mm round holes, 20.9 % open surface area and alternative perforations on request, While ideally controlling heat gain and light, the fins also preserve views to the outside and broaden the occupantsโ visual space. The elegant and transparent Aeroscreen System acts perfectly well with the sedate appearance of a building, creating a beautiful look with unique charm. ``The module C/C of fin for fixed system will be 500MM and the length of the fin shall be determined based on the wind load calculation and deflection and upto a maximum of 3500MM. The factory made Luxalon Aeroscreen 450 mm fin will be fixed on both ends to suitable Installation frames of MS sections/Aluminum provided by Client. The installation frame shall be fixed mechanically to concrete structure with MS or Aluminum brackets. The erected substructure shall be aligned within the tolerances of ยฑ span/1000 of plumb line and level with a non-cumulative tolerance of a maximum of 2 mm. The louver Fin skin Surface Coating: Front side Skin: Coil Coated with PVDF in approved colour: Back side Skin: With standard Primer. Alum. Extrusions: All extrusions are Natural anodized.The Rate includes labour, material, fixtures, accessories, Anchor Fastners etc complete as per drawings and specifications. Nothing Shall be paid extra. |
| 159 | Supply and Installation of Hunter Douglas Terracotta pure mined clay tiles 16mm/18 mm thickness (Length: 1200 mm, Height: 300 mm). The tiles would-be back ventilated, with self-draining open joint system. Tiles shall be double-leaf construction and have labyrinth top and bottom returns to prevent easy water access behind tiles. Water absorption to be in between 3% to 6% conforming to ISO 10545 - 3, average bending tensile strength of tile =18mm shall be = 4500N conforming to ISO 10545- 4, Freeze / Thaw resistance conforming to ISO10545-12, Chemical resistance conforming to ISO 10545-13, Modulus of rupture shall be =16MPaconforming to ISO 10545-4, resistance to thermal shock shall be conforming to ISO 10545-9,Chemical resistance shall be no less than ULB level conforming to ISO 10545-13, Resistance to stains shall be conforming to ISO 10545-14. The tiles shall be of Natural Brick Red Terracotta Color and natural finish. The tolerance allowed in length is ยฑ 1mm, height of front side is ยฑ 2mm, height of back side is plus 2mm and - 3mm, thickness is ยฑ 1.5mm, straightness of side is ยฑ 2mm, vertical flatness is ยฑ2mm, diagonal flatness is ยฑ 2mm as per ISO10545-2. Aluminum support system: The support system consists of extruded Anodized Aluminum vertical Full T-and Half T Tracks of Alloy 6063T5.The dimension of T-Tracks would be 102X53X2 mm and maximum length of 5000 mm. A vertical black PVC gasket (max. length 5000 mm) would be slid on the T-Track between two tiles at vertical joint for proper alignment and extra support.The T-Track is to be mounted on extruded anodized Aluminum dead-load and wind-load Wall Bracket of Alloy 6063T5. The dimension of it would be100/120 X 70/90 X 50 X 4 mm. The extruded Aluminum Clips of Alloy 6063T5 and thickness 2mmwould be fastened on the pre-punched T-Track on which the Terracotta tiles are to be mounted. The vertical aluminum T-tracks with gaskets and tile clips shall serve to hold terracotta pure natural clay tiles. The clay tiles will be resting on a double bulb rubber gasket fixed to the Aluminum extrusion clips to enable the tiles to have expansion contraction movement. System is designed to accommodate thermal movement. Terracotta tiles shall be removable, without breakage or disruption to adjacent tiles. The clips shall be concealed. Fastening devices: Stainless steel screws, anchor fasteners, nut and bolt are not in HDI scope shall be provided by the contractor. The basic design of the aluminum support system for TILES must be based upon the open ventilated facade principle. Building components must be designed to accommodate imposed loads from the aluminum support system and terra cotta tile. Building components must be designed so their deflection under imposed loading will not cause deflection of aluminum support system of exceed specified tolerances. Terracotta Dimensional Tolerance: The tolerance allowed in length is ยฑ 1mm, height of front side is ยฑ 2mm, height of back side is plus 2mm and - 3mm, thickness is ยฑ 1.5mm, straightness of side is ยฑ 2mm, vertical flatness is ยฑ 2mm, diagonal flatness is ยฑ 2mm as per ISO10545-2. Tile Color: The tiles shall be of M6.02 Color and natural finish. Colour: Natural Brick Red Terracotta (6.02), Finish: PLAIN |
| 160 | Providing and fixing 12mm thick toughened glass in Aluminium frame work including sealing with EPDM / Neoprene gasket all complete as per the architectural drawings and the directions of engineer-in-charge. |
| 161 | Supply and fixing of Half Fin fixed louver 250 consists of elliptical profiled louver fins kin with crowning manufactured out of 0.7 mm thick enamelled corrosion resistance aluminium Alloy AA 3105 and formed on high speed high precision DALLANCOMBI multistage roll forming system or equivalent. The roll formed fin profile is mechanically fixed between aluminium extruded press plate and continuous assembly channel. Then nylon end caps shall be provided on both sides of the fins. The louver fin skin shall be coil coated finish suitable for exterior applications. The coil is coated on a continuous paint line double baked and shall be stove enamelled and finished with special three layered coating system(consisting of first a conversion layer of thickness 800-2000mg/sq.mtr,a polyurethane base coat of 16-20 microns, and a special top coat of polyamide particles of 8-12microns thick to provide excellent abrasion and damage resistance)in a continuous coil coating process of the approved colour on the exposed side and the reverse side with epoxy. Paint performance criteria: โขCoating thickness shall be 24 to 32 ยตm and determined by ECCA T1. โข Colour difference shall be H and determined by ECCA T3 โข Corrosion resistance shall be 3 Years under creep ( 2 mm (Outdoor exposure) and determined by ECCA T19 โข U V Ray Resistance shall be determined by ECCA T19 No crack / flacking/ blistering/ chalking for minimum period of 5 Years. Colour change shall be ( 5 units, gloss loss ( 50%โข Humidity Resistance as per ISO 6270,1000 Hours blistering ( B2S2โข Salt /Acetic Acid Spray Test shall be as per ASTM G85,1000 Hrs. under creep ( 2mm The fins fixed to substructure with Installation bracket and necessary screws.The factory assembled louver fins of 250mm projection and as per the length width 70-72mm width shall be fixed mechanically to installation frame of Aluminium/MS provided by others with total projection of 216mm from the installation frame in the module of 350mm c/c. The louver Fins shall be provided in 350 mm module in varying lengths as per site requirements subject to a maximum of 3.5 - 4 Mtr. The installation frame shall be mechanically fixed to a structure 300 mm distance from the fin panel edges and a c/c maximum distance of 2000 mm in between subject to wind load. The erected installation frame shall be aligned with in the tolerances of ยฑ span/1000 of plumb line and level with a non-cumulative tolerance of a maximum of 2mm. (Note Sub-structure will be paid in separate item.) .Green pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. Any kind of MS substructure Required at site shall be in Client/Contractor`s scope. |
| 162 | Providing and fixing glass reinforced concrete (GRC) customized jali 50mm thick on Aluminium Frame work (Tubular section of size as required). Approximate size of Jali 1100 mm x 1800mm).Basic Rate of jali 4200 Rs./SqM excluding taxes, freight and loading and unloading. |
| 163 | Supply, Installation, Testing and Commisionig of Extruded Polystyrene Boards (XPS) of Thickness - 100mm (SX60Grade) on terrace with Protection Screed: Over the HDPE of 300 microns layer, providing and laying Cement Screed of Average Minimum thickness of 50 mm and finishing the same as per below Specifications with desired slope:a). Thorough cleaning the surface.b). Providing and laying Average Minimum 50mm thick Cement Screed with M-20 grade concrete mixed with Recron Polypropylene fibre @ 125 gms per bag of cement with Latex .c) On green screed concrete, Cutting the construction joints of size 6mm x 15 mm (within 12 to 36 hours after laying the concrete) by making the panel size of 2 mtr x 2 mtr..d). Filling the construction joints by using Polyurethane sealant. Complete as per specification.e) Final finishing with desired Tiling by using Tile adhesive as required. |
| 164 | Supply and installation of Fire Barrier Joint Spray system RFS 640 with minimum 2 hours F rating (integrity rating) when tested in accordance with ANSI/ASTM E 2307 standards for Determining Fire Resistance of Perimeter Fire Barriers.The Joint spray shall be a flexible material to accomadate the movement of curtain wall joint and must be tested to Class II Movement Capabilities. The backing material like mineral wool/ stone woll of 64 density shall be compressed for 30% and fit into the joint in compression zone as per the recommendation of manufacturer. The cost shall include support system or other miscellaneous items etc.., Considering 100mm joint width(Makes- Fischer,Hilti,3M) |
| 165 | Supply and installation of Fire Barrier compound with minimum 2 hours fire rating when tested in accordance with ASTM E 814 / UL 1479 standards, for fire rated vertical openings in floors or slabs and floors made of concrete, masonry, metal, gypsum partition, after passing service lines like Cable,Cable trays or Metal pipes. The compound shall be a light weight gypsum /cementitious product and shall carry CE and UL marking on the pack.The product shall be tested to ASTM G21 mold and mildew test.The product shall be tested to meet the VOC limits and shall meet the leed requirments. (Makes- Fischer,Hilti,3M) |
| 166 | Supply and installation of Fire Barrier sealant with minimum 2 hours fire rating when tested in accordance with ASTM E 814 / UL 1479 standards, for fire rated vertical openings in floors or slabs and floors made of concrete, masonry, metal, gypsum partition, after passing service lines like Bus duct, cable trays ,combustible pipes. The sealant shall be flexible product and shall carry UL marking on the pack.The product shall be tested to ASTM G21 mold and mildew test.The product shall be tested to meet the VOC limits and shall meet the leed requirments. (Makes- Fischer,Hilti,3M) |
| 167 | Provide Fire resistant sealant with 64 density mineral wool backing in services passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity in accordance to EN 1366-3 / ASTM E 814/UL 1479 standards.After passing service lines like metal ducts, metal pipes. Sealant to provide sufficient water and gas tight seal . All installations to be in full accordance with the manufacturer recomendation. Considering 50mm annular gap around services maximum (Makes- Fischer,Hilti,3M) |
| 168 | Fire hydrant wallSupply and installation Fire sealant with minimum 2 hours fire rating when tested in accordance with EN 1366-3 / ASTM E 814 / UL 1479 for vertical openings in walls after passing service lines like Metal Pipes. Sealant Application to be done on both sides of wall. Considering 50mm annular gap around services maximum(Makes- Fischer,Hilti,3M) |
| 169 | Fire hydrant wallSupply and installation Fire sealant with minimum 2 hours fire rating when tested in accordance with EN 1366-3 / ASTM E 814 / UL 1479 for vertical openings in walls after passing service lines like Metal Pipes. Sealant Application to be done on both sides of wall. Considering 50mm annular gap around services maximum(Makes- Fischer,Hilti,3M) |
| 170 | Item Description |
| 171 | CONSTRUCTION OF SCADA BUILDING AT SECTOR-20B, FARIDABAD Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 ยท All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail