| 1 | Taking up or down steel water tubing, 80 mm bore including fitting connections and cleaning tubing, fitting/ cutting threading of serviceable tubing for relaying and removal of unserviceable tubing all as directed by Engr-In- Charge. |
| 2 | same as serial item no 1 but 50 mm dia |
| 3 | same as serial item no 1 but 40 mm dia |
| 4 | same as serial item no 1 but 25 mm dia |
| 5 | same as serial item no 1 but 20 mm dia |
| 6 | Supply & Laying , jointing,testing in replacement of Steel water tubing, 80 mm bore, medium grade, galvanised with all fittings laid in trenches. complete all as specified and directed. |
| 7 | same as serial item no 6 but 50 mm dia |
| 8 | same as serial item no 6 but 40 mm dia |
| 9 | same as serial item no 6 but 25 mm dia |
| 10 | same as serial item no 6 but 20 mm dia |
| 11 | Fixing/laying only old water tubing, 50mm bore, fixed to walls and ceiling or laying in floors or in trenches with new fittings & fixtures to make it functional complete all as specified and directed. |
| 12 | same as serial item no 11 but 40 mm dia |
| 13 | same as serial item no 11 but 25 mm dia |
| 14 | same as serial item no 11 but 20 mm dia |
| 15 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying pipes/repair to pipes and sluice/control valves etc. complete all as specified and directed. |
| 16 | Returning filling in trenches, including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as directed. (Surplus soil if any shall not be removed but left proud over the trench) |
| 17 | S&F in replacement of Gun metal globe or gate valve, 50 mm bore (Class-I) ISI marked, with iron wheel head screwed both ends for iron pipe complete fixed as in repair all as specified. |
| 18 | same as serial item no 17 but 40 mm dia |
| 19 | same as serial item no 17 but 25 mm dia |
| 20 | same as serial item no 17 but 20 mm dia |
| 21 | Pre-cast cement concrete hollow block masonry type 1:3;6, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L rendering 15mm thick on Brick masonary in internal surfaces in CM 1:4 finished even and smooth with sagol finish complete all as specified and directed. |
| 23 | M&L for Preparation of newly Plastered or un-Plastered surfaces of walls and applying three coats of white wash complete all as Specified and directed. |
| 24 | M & L for mild steel rolled section connected with each other with welding (angle, tee, channel, beam, hollow sections etc) as in main and cross beams, hip verticle hollow sections and jack rafters, purlins where connected to common rafters and running rils where verticle suctions and fixed in welded in wallsin wall surface with plates and other verticle sections are fixed in ground level embedded in concrete fixed and horizontal sections fixed in wall with bolt completly, fixed with angle, cleats with painting two coats of syntetic enamalled paint over and red oxide primer or other connecting plates conforming to Gde Fe -410-W (Gde E-250) quality-B complete all as specified and directed by Engr-in-charge |
| 25 | All as per item no 24 above but plates (plain or chequered channels, square cut or notched (ordinary and counter sunk) forming holes, without any attchement |
| 26 | S & F in replacement of Pre painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified and directed |
| 27 | S & F in replacement of Pre painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified and directed |
| 28 | S & F in replacement of Fiber glass reinforced translucent corrugated 2mm sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc fixed with self tapping screws as specified and directed |
| 29 | M&L for Glazed ceramic white tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including taking down old one. |
| 30 | M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including taking down old one |
| 31 | M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade With Grey Cement andv pigment complete all as directed. |
| 32 | PCC 1:4:8 type D-2 using 40mm stone agg as in foundation , filling and mass concrete on water tank stage, complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F in replacement of aluminium colour powder coated anodised door and shutter or double leaf glazed/pre laminated board exterior quality partly glazed/pre laminated board exterior quality partly glazed panels fabricated including aluminium anodised beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size including fixing of aluminium hinges of any description complete comprising the following:-(a) Aluminium colour anodised door frame section 101.60x44.45x1.93 mm fixed as per spd(b) Aluminium colour anodised verticle section in shutter 85x44.45x2 mm as per spd(c) Aluminium colour anodised top & style shutter section 95.25x44.45x2.00 mm as per spd (d) Aluminium clolour anodised handle 02 Nos in each shutter 200 mm long as spd(e) Aluminium clolour anodised middle lock rail/bottom rail section 150x44.x2.65mm cat No 20002 (f) Floor spring (g) Six lever mortice lock brass 125 mm(h) 12mm thcik particle board (pre laminated both face) exterior grade ISI Marked(j) Tinted glass/plain glass (colour) 5mm thickNote :-glass or full panel shall be provided as per direction of Engr-in-Charge |
| 34 | Construction of brick masonary valve pit of size 900x900x900mm (Internal dimension) incl necessary earth work and MS sheet 3 mm thick cover with angle iron frame 40 mm x 40 mm x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer all as shown in drg held with GE office complete all as specified directed. Please Enable Macros to View BoQ information |
| 35 | Construction of brick masonary valve pit of size 900x900x900mm (Internal dimension) incl necessary earth work and MS sheet 3 mm thick cover with angle iron frame 40 mm x 40 mm x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer all as shown in drg held with GE office complete all as specified directed. Please Enable Macros to View BoQ information |