| 1 | Dismantling wrought iron or mild steel work of any description not otherwise described complete all as specified and directed. |
| 2 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed. |
| 3 | M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 4 | Demolition of brick or stone boulders masonary built in cement mortar or cement lime mortar including all quions, arches pillars etc but excluing ashlar facings ressed stone works and precast concrete artiles , complete all as specified an irecte.work in CM complete all as specified and directed |
| 5 | M&L for Brick work with sub class ‘B’ bricks, straight or curves on plan exc 6 mtr mean radius old size bricks built in Cement Mortar (1:4), complete all as specified and directed |
| 6 | M&L for Rendering 15mm thick in CM (1:4) on fair faces of brick masonry/ concrete surfaceon wall with using water proofing compound and finishing the surfaces even and smooth withoutusing extra cement , complete all as specified and directedNote:- WPC shall be measured & paid for separately as “Supply only under respective items .’ |
| 7 | Supply only integral water proofing compound ISI marked complete all as specified and directed. |
| 8 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 clear span , cills steps seismic and other similar bands, copings, hold fast an the like incluing weathering , slightly rounded or chamfered angles and throating asdirected with and icluding necessary form work in CM 1:4 complete all as specified an directed. |
| 9 | M&L Concrete bed to 150mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested; in PCC (1:4:8) complete all as specified and directed |
| 10 | Description all as per item Srl No. 9.00 here in before but for 200mm bore of pipe complete all as specified and directed. |
| 11 | M&L 150mm internal dia of pipe salt glazed stoneware drain pipe Grade 'A' laid in trenches and jointed in cement & sand morater 1:1 and testing complete all as specified and directed |
| 12 | Description all as per item Srl No. 11.00 here in before but for for 200mm bore of pipe complete all as specified and directed. |
| 13 | Demolition and breaking up Drain pipes (SGSW, AC or reinforced concrete) 150mm bore set in cement mortar complete all as specified and directed |
| 14 | Description all as per item Srl No. 13.00 here in before but for but for 200mm bore of pipe complete all as specified and directed. |
| 15 | M&L for Cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 roun or 3/4 section) in cement concrete (1:2:4) type -B1, smooth finished , and reforming benching as required complete all as specified and directed |
| 16 | M&L for Cutting into existing manholes for connecting new drains 200mm dia making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 roun or 3/4 section) in cement concrete (1:2:4) type -B1, smooth finished , and reforming benching as required complete all as specified and directed . |
| 17 | Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth in soft/loose of soil for foundation, etc. or for shafts, wells cesspits, manholes, pierholes etc and getting out complete all as specified an directed. |
| 18 | Description all as per item Srl No. 17.00 here in before but for but exceeding 1.5 deep and not exceeding 3m deep complete all as specified an directed. |
| 19 | M&L for returing filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 20 | Removing of excavated material (Soil) to a distance exc 250m but not exceeding 500 mtr and depositing at a level n.exc 1.5 m above the starting points complete all as specified an directed |
| 21 | Demolition of (reinforced cement concrete) (reinforcement cut as required to facilitiate demolition) of any description and in any positionnot otherwise specifically provided for complete all as specified an directed. |
| 22 | M&L for reinforced Precast cement concrete(1:2:4) type B-1 using 20 mm graded stone aggregate as in landing , cover slab (for manholes, shelves), chullah hoos, chajjas, water troughs , mangers, shelves an similar articles with plain faces incluing necessary form work , & set in Cement Mortar (1:4) in complete all as specified an directed.Note:-Reinforcement shall be measured and paid for separately in respective items |
| 23 | M&L for Mild Steel TMT bar, 10 mm dia & Over , cut to length, bent to shape require, incluing cranking , bending spirally for hooping for columns ,hooking endsa and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed |
| 24 | Demolition of plain cement concrete ( Un reinforced)of any description in any position not otherwise specifically provied and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr , complete all as specified and directed. |
| 25 | M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate as in foundation filling & Mass concrete , sub base complete all as specified and directed. |
| 26 | M&L 75mm thick PCC 1:3:6, type C2, using 40mm graded aggregate as in Ramp/Plinth protection and platform and floor including finishing cement concrete surface even and smooth W/O using extra cement complete all as specified and directed. |
| 27 | M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in surface channel and drain incluing necessary form work complete all as specified and directed. |
| 28 | Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed. |
| 29 | M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of size 350x250x7mm/ 450x350x7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed. |
| 30 | M&L for non skid Ceramic tiles,first quality( of approved class , colour and design/ shade ) 6 to 7 mm thick( square/ rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, ,as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles over with and including 15 mm Screed bed in Cement mortar 1: 6 Complete all as specified and directed. |
| 31 | S&F in repair white vitreous China wash down water closet pan (pedestal) pattern, and trap (excluding) fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. with and including plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device and 15mm dia chromium plated brass washing jet fixed to water closet with 15mm dia and 1.2m to 1.5m long flexible pipe with chromium plated spring type cover complete with fixing arrangement fancy look complete all as specified and directed. |
| 32 | S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed. |
| 33 | S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed. |
| 34 | Taking down Cast iron/PVC pipe of any dia and size fixed on wall or floor including all fittings complete all as specified. |
| 35 | S&F 110mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 36 | S&F 110 mm dia PVC(SWR) bends/ shoes any radius complete all as specified and directed. |
| 37 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 38 | S&F 75 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 39 | S&F 75 mm dia PVC(SWR) bends/ shoes any radius complete all as specified and directed. |
| 40 | S&F 150 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 41 | S&F 150 mm dia PVC(SWR) bends/ shoes any radius complete all as specified and directed. |
| 42 | S&F 500 litre capacity rotational moulded polyethylene water storage tank (cylindrical vertical double layered with closed top) duly provided with necessary fittings/ fixtures for connecting inlet, outlet, washout and overflow pipes; hoisted and fixed in position incl dismantling PVC water sotrage tanks of capacity more than 250 to 500 litres capacity complete all as specified and directed. |
| 43 | S&F 1000 litre capacity rotational moulded polyethylene water storage tank (cylindrical vertical double layered with closed top) duly provided with necessary fittings/ fixtures for connecting inlet, outlet, washout and overflow pipes; hoisted and fixed in positionincl dismantling PVC water sotrage tanks of capacity more than 500 to 1000 litres capacity complete all as specified and directed. |
| 44 | M&L for Cleaning of septic tank up to 25 users by removing sludge in semi solid sate or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 45 | M&L for Cleaning of septic tank exc 25 users and not exc 50 users by removing sludge in semi solid sate or liquid state by manually or by pressure pump including removal of sludge to a distance exc1.5 km but n exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. |
| 46 | M&L for Cleaning of septic tank exc 50 users and n.exc 100 users by removing sluge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 47 | M&L for Cleaning of septic tank exc 100 users and n.exc 200 users by removing sluge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 48 | M&L for Cleaning of septic tank exc 200 users and n.exc 300 users by removing sludge in semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5 KM but n. exc 2 KM out of MOD land and buried into ground by digging pits spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 49 | M&L for Dewatering of soak well or sewage of any dia and depth manully or by using pumps and rremoval of sludge if any to a distance exc1.5km but not exc 2Km out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 50 | M&L for cleaning of Sewage pipe line from gully trap to Its manhole an then upto the final drop into the septic tank an soak well /cess pool (except intermediate manholes ) by removing all blockage of any description in any situation in the system complete any ia of pipe an epth by rodding ,manually or by pressure pump including removal of sludge to a distance exc1.5km but nexc 2KM out ofMOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed . |
| 51 | Cleaning and make it functional the sewage system by removing of all types of blockages from soil waste/rain water pipes, CI waste pipes, blockages of Toilets/bathrooms/WHB/Kitchen of bldgs upto G+7 storey height or in trenches, sewage line of any dia including junction of manholes of any description, man holes and septic tanks of any size and depth upto the last manhole to septic tanks of central sewage system to keep smooth functioning without any blockage of any description and in any situation with manually or some mechanically processes for all locations of Technical and Residential area of IRDE under GE (I) R&D Dehradun all as specified , by providing Three (03) numbers of safaiwalas/Sewer workers per day including all necessary tools and plants like Shovel, Sewer/Drain rod, bucket, rope, ladder etc .The Contractor or rep of contractor has to attend sub-division on a daily basis to collect the complaints. The Feedback should be submitted within 24 Hrs without any fail. |
| 52 | M&L for preparing old surfaces of walls plastered plastered by complete removal of existing treatment by electric grinder brooming down with steel or wire brush and scraping down smoke soot, moulds moss & efflorescent salt and trading oil and greasy spots , washing rubbing down and stopping of distempered and painted surface & removing all vegetation growth, nails and making good holes,cracks etc complete by necessary putty and make the surface smooth by rubbing with sand papers etc and applying two coat of approved shade of oil emulsion distemper, complete all as specified and directed |
| 53 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed Please Enable Macros to View BoQ information |