| 1 | Demolition of brick or stone/ boulder masonary, built in cement mortar complete all as specified and directed. |
| 2 | Demolition of un-reinforced cement concrete in ground floors not exceeding 15 cm thickness including floor finish complete all as specified and directed.. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 4 | All as per item no.3 above but for each additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and directed. |
| 5 | Removing excavated soils exc. 250 m and n.exc.500 m depositing where directed at a level n. exc. 1.5 m above starting point all as specified and directed. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 7 | M&L for Plain Cement Concrete Type 1:3:6 type C-2 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 8 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed. |
| 9 | Rendering 15mm thick CM of 1:4 on fair faces of brick work or concrete surfaces finished even without using extra cement as all specified and directed |
| 10 | Rendering 15mm thick CM of 1:4 on o on stone masonry surfaces or surface other than fair face of brick-work without using extra cement as all specified and directed |
| 11 | M&L Preparing new surfaces on external walls and applying two coats of Cement base paint complete all as specified and directed. |
| 12 | M&L Stone walling of random rubble un coursed well bonded bedded and solidly hearted built in cm 1:6 etc all as specified and directed. |
| 13 | Extra over stone walling for Granite or Trap stone for hammer dressing to face stones and dressing of face of beds and joints, as specified of random rubble walling, un coursed or brought up to course with maximum depression on face straight edge held against the dressing surface not exc 40mm etc complete all as specified and directed. |
| 14 | M&L for keyed pointing to random or polygonal rubble uncoursed or brought upto courses in CM (1:4) complete all as specified and directed. |
| 15 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, benching, in lintels upto 1.5m clear span, cills, steps; plinth courses, parapets and railings upto 60 cm in height, including weathering, slightly rounded or chamfered angles and throating all as specified and directed. Please Enable Macros to View BoQ information |