| 1 | Dismantaling structural steel work incl doors, gates but excluding framed trusses etc complete all as specified and directed. |
| 2 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 3 | S&F MS Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completFe-290, Gde-E-165 complete all as specified and directed. |
| 4 | Demolition of brick work / stone masonry/PCC block built in cement mortar of any description complete all as specified and directed. |
| 5 | M&L walling of random rubble, uncoursed, Bangalore type masonry well bonded bedded solidly hearted built in CM 1:6 complete all as specified and directed. |
| 6 | All as per item No (4) above except stones complete all as specified and directed. |
| 7 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6.00m mean radius built in cement mortor 1:6 complete all as specified and directed. |
| 8 | Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement and user water proofing compound. (Note : WPC will be measured and paid separately under relevant item) complete all as specified and directed. |
| 10 | Supply only liquid water proofing compound complete all as specified and directed. |
| 11 | M&L raised pointing to random or polygonal rubble, un- coursed stone masonry or brought upto courses in CM 1:4 complete all as specified and directed. |
| 12 | M&L for 600mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars laid over PCC bed with haunching and testing for leakage complete all as specified and directed. |
| 13 | M&L for cement concrete bed (1:3:6) type C-2 using 40mm graded stone aggregate to drain pipe of 150 mm bore including packing under hunching against the site of pipe after they are laid and tested complete all as specified and directed. |
| 14 | M&L preparation of new plasterd wall surfaces and applying two coats of cement based paint over a coat of primer and complete all as specified and directed. |
| 15 | M&L preparation of new steel surface over 10Sqm cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer and complete all as specified and directed. |
| 16 | M&L preparation of old plastered wall surface incl. washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of cement based paint and complete all as specified and directed. |
| 17 | M&L for preperation of old painted surfaces of steel and iron work of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint any tint complete all as specified and directed. |
| 18 | Demolition of Concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 19 | M&L Providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in roof, chajjas, coping, bed blocks and similar work including necessary form work complete all as specified and directed. |
| 20 | M&L for Plain cement concrete 1:5:10 type E2 using 40mm graded stone aggregate as in filling and mass concrete complete all as specified and directed. |
| 21 | Material and labour for 50mm thk PCC 1:2:4 type B-1 using 20mm graded stone agg as in flooring finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for cement concrete 1:3:6 type C-2, 75 mm thick using 40mm graded stone aggregates as in plinth protection/PCC path complete finished fair and even complete all as specified and directed. |
| 23 | M&L for Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com- pound, Grade ‘A’ complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in surface channel and drain incluing necessary form work including Demolition of plain cement concrete ( Un reinforced) of any description in any position and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000 m complete all as specified and directed. |
| 25 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 26 | Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 27 | M&L reinforcement cement concrete nominal mix 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork complete all as specified and directed. |
| 28 | M&L for providing pre cast concrete type B-1 (1:2:4) using 20mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 29 | M&L Mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cracking bending spirally hooking ends and binding with MS wire (annealed) no less than 0.90 mm dia complete all as specified and directed. |
| 30 | M&L Formwork to soffits of suspended slabs such as flat roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick rough finished surfaces of concrete (Horizontal or sloping) complete all as specified and directed. |
| 31 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid/bedded and pointed in any type of mortar and removing from site upto 500 mtr distance complete all as specified and directed. |
| 32 | M&L for 100mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 33 | M&L for 40mm thick layer of sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 34 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with white cement and no pigment including taking down of old one complete all as per direction of Engineer-in-Charge. |
| 35 | M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 36 | M&L for removing excavated/demolished material exc. 1.50 km but n exc. 5 km and depositing where complete all as specified and directed. |
| 37 | M&L for de-silting of drainage system of any dia and depth manully or mechanically and removal to a distance exc1.5km but not exc 2Km out of MOD land and buried into ground by digging pits and spray a layer of bleaching @ 0.50 kg per sqm area to avoid any type of infection in enviornment complete all as specified and directed. Please Enable Macros to View BoQ information |