Tender For Comprehensive Maintenance And Repairs To Ht 33/11 Kv Mrs And Other Substations, Ht Panels, Ht Vcb, Transformers Connected Infrastructure At Domestic Area Under Ge (Af) Bidar, Bidar-Karnataka
TDR : 55702734
Tender Notice
BOQ
21 Days Left
Bidar
Karnataka
Tender For Comprehensive Maintenance And Repairs To Ht 33/11 Kv Mrs And Other Substations, Ht Panels, Ht Vcb, Transformers Connected Infrastructure At Domestic Area Under Ge (Af) Bidar
Name of Work:- COMPREHENSIVE MAINT AND REPAIRS TO HT 33/11 KV MRS AND OTHER SUBSTATIONS, HT PANELS, HT VCB, TRANSFORMERS CONNECTED INFRASTRUCTURE AT DOMESTIC AREA UNDER GE (AF) BIDAR
Sl. No.
Item Description
1
Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 3 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period for insulation resistance testing, CRM testing, 3 pole timing testing with transportation under AMC and duly carring out servicing,overhauling, calibration by using suitable test kits, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom) of any technical specification of 33 KV grade VCB current rating 400/630/800/1250 Amps (incoming/out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side in all respects after complete servicing with facilitated operating features, and cleaning,overhauling,relay calibration and review the control switches with wiring and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed.
2
Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 2 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period duly carring out servicing,overhauling, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom /Scheneider/L&T) of any technical specification of 11 KV grade VCB current rating 400/630/800/1250 Amps (out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side operations in all respects and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed. Please Enable Macros to View BoQ information
3
Comprehensive maintenance and general servicing to switchgear (VCB/RMU) once in maint period and 2 visits as specified by Engr-In-charge and attend VCB complaints on demand/fault under maint period duly carring out servicing,overhauling, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom /Scheneider/L&T) of any technical specification of 11 KV grade VCB current rating 400/630/800/1250 Amps (out going feeders) Including for checking, examining complete VCB in terms of electrical and mechanical side operations in all respects and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory of Engr-In-charge Complete all as specified and as directed. Please Enable Macros to View BoQ information