| 1 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed by the Engr-in - Charge. |
| 2 | M & L for RCC (Desgin Mix M-30) using 20 mm grade stone aggregate in Slabs supported on walls,beams and columns in floors,roofs, landings, conies,canopies, deck slabs and in shelves and the like etc complete all as specified and directed by the Engr-in - Charge. |
| 3 | M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed by the Engr-in - Charge. |
| 4 | M&L fo Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete complete all as specified and as directed by the Engr-in - Charge. |
| 5 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete precast concrete block walling complete all as specified and as directed. |
| 6 | M&L for squared rubble walling, Jodhpur type, brought up to courses, well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified and as directed by Engr-in-Charge. |
| 7 | All as per item No. 06 above but except stone complete all as specified and as directed by Engr-in-Charge .Note:- Old stones obtained from demolition shall be reused under this item. |
| 8 | M&L Rendering 15mm thick on fair faces of stone work or concrete surfaces in CM (1:4) and finishing the surface even and smooth complete all as specified and as directed by the Engr-in - Charge. |
| 9 | M & L for preparation of old concrete/bitumen surfaces on rigid / flexible portion of Runway/Taxi track by brushing, washing, rubbing by gunny bags over 10cm width or girth of any description and applying one coat of Ist quality exterior weather proof water base emulsion on lines, dashes arrows, letters etc any tint paint all as directed by Engr-in-Charge |
| 10 | All as per item No 09 above but n exc 10 cm width or girth when unconnected with other painting or when painted in a different tint |
| 11 | Supply & fixing in repairs High intensity prismatic grade retro reflective self adhesive sheeting on runway DTGM board, size of letters 100cm to 150cm high, 70cm to 80cm wide with letter width of 15cm to 16cm fixed in DTGM board (0,1,2,3,4,5,6,7,8,9 and M) complete all as specified Make :- 3M, dark Eye or equivalent as approved by GE.Note : The work will be carried out as per user requirement from 1830 hrs to 0600 Hrs. The deployment of labour and T&P arrangement on the Runway shall be intimated to the contractor lby 0800 Hrs each day in the moring. The contractor has to provide necessary arrangement such as lights etc and quote the rate accordingly for considering late working hours at night. Nothing extra will be paid on this account. |
| 12 | S & F for framed work of angles, channel or steel tubes such as grills, gratiings, etc with ends of bars shouldered and / or riveted or forged into spikes, framed, illuminated wind direction indicator and similar work conforming to Fe 290. Gde E-165 all as specified and directed. |
| 13 | S & F IS marked ball bearing for 90mm inner dia all as specified and directed. |
| 14 | Supply & fixing in repairs 3 mm thick PVC Acrylic sheet for light sign board with one side clear sheet and one side encrepted sheet with black/white letter and yellow/black back side and fixed withself adhesive sheeting on runway board and sign boards as lines, dashes, arrows, letters etc including removing old/existing sheeting complete all as specified and directed by Engineer-in-Charge. Make :- 3M, dark Eye or equivalent as approved by GENOTE:- The work will be carried out as per user requirement from 1830 hrs to 0600 Hrs or as directed. The deployment of labour and T&P arrangement on the Runway shall be intimated to the contractor by 0800 Hrs each day in the morning. The contractor shall be provide necessary arrangement such as lights, portable generator, pneumatic road roller, bitumen paver, bitumen sprayer and other required T&P etc and quote the rate accordingly for considering late working hours at night. Nothing extra will be paid on this account. |
| 15 | M & L for preparation of old concrete/bitumen surfaces on rigid / flexible portion of Runway/Taxi track by brushing, washing, rubbing by gunny bags over 10cm width or girth of any description and applying one coat of synthetic enamel paint to lines, dashes, arrows, letter etc (First quality ) any tint paint all as directed by Engr-in-Charge |
| 16 | All as per item no 15 aove but n exc 10 cm in width or girth when unconnected with other painting or when painted in a different tint. |
| 17 | Supply and fixing in repairs taxiway / runway sign board having UV protected face plate on both sides not more than 1.0 Sqm each consisting of non-metallic materials support structure having min tensile strength 4000.00 Kg/ Sqcm impact strength of 139.00 Kg/Sqcm, and able to withstand wind speed of 30m/s, with high intensity prismatic grade retro reflective sheeting as base and with cut out message (legends boarders letters numerals etc) sign board frame shall fixed in frangible coupling embedded in PCC 1:2:4 type B1 block of size 15cm x 15cm x 15cm complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fixing in repairs taxiway / runway sign board having UV protected face plate on both sides size exceeding 1.00 Sqm but not exceeding 2.00 Sqm each consisting of non-metallic materials support structure having min tensile strength 4000.00 Kg/ Sqcm impact strength of 139.00 Kg/Sqcm, and able to withstand wind speed of 30m/s, with high intensity prismatic grade retro reflective sheeting as base and with cut out message (legends boarders letters numerals etc) sign board frame shall fixed in frangible coupling embedded in PCC 1:2:4 type B1 block of size 15cm x 15cm x 15cm complete all as specified and directed by Engr-in-Charge. |
| 19 | Supply and fixing in repairs taxiway / runway sign board having UV protected face plate on both sides size exceeding 2.00 Sqm but not exceeding 3.00 Sqm each consisting of non-metallic materials support structure having min tensile strength 4000.00 Kg/ Sqcm impact strength of 139.00 Kg/Sqcm, and able to withstand wind speed of 30m/s, with high intensity prismatic grade retro reflective sheeting as base and with cut out message (legends boarders letters numerals etc) sign board frame shall fixed in frangible coupling embedded in PCC 1:2:4 type B1 block of size 15cm x 15cm x 15cm complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge. |
| 21 | M&L for cement concrete 1:2:4 type B2 (using 20 mm graded aggragate) in foundation,mass filling and edges for interlocking tiles complete all as specified and as directed |
| 22 | Fixed in repair for 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory co mpaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete |
| 23 | M&L for clearing/cutting bushes, scrubs, grass, vegitation from side/berms/shoulders of Runway/PTT/Taxi/Dispersal and adjoining area by manual / mechanical means (by using jungle jim or petrol grass cutter machine in adequate numbers) as per site requirment including transport for removing all the debries out side MoD land complete all as specified and as directed.Note for all items above.The work will be carried out as per user requirement from 1830 hrs to 0600 Hrs. The deployment of labour and T&P arrangement on the Runway shall be intimated to the contractor lby 0800 Hrs each day in the moring. The contractor has to provide necessary arrangement such as lights etc and quote the rate accordingly for considering late working hours at night. Nothing extra will be paid on this account. Please Enable Macros to View BoQ information |