| 1 | S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 12 ways with IP43 protection complete all as specified and directed. (Note: MCB should be B curve as directed by engineer in charge) |
| 2 | S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP43 protection complete all as specified and directed. (Note: MCB should be B curve as directed by engineer in charge) |
| 3 | Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 4 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The DB shall be fiush fixed and making good the disturbed surface shall be part of job at no extra cost. |
| 4 | Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 2 way single door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The DB shall be fiush fixed and making good the disturbed surface shall be part of job at no extra cost. |
| 5 | Supply & fix in replacement of old MCB DB TPN 4 Way with 200Amp standerd bus bar factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCB TPN upto 125A complete all as specified and directed. (MCB TPN will be measured and paid separately under respective items of BoQ) |
| 6 | S&F MCCB DB VTPN 4 WAYdouble door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for ways with IP43 protection complete all as specefied and directed. (Note: MCCB should be B curve as directed by engineer in charge) |
| 7 | Supply and fix factory made epoxy powder coated MCCB distribution box for double door VTPN 6 way vertical type AC 415 V with IP 43 protection for MCCBs alongwith provision of MCCB as incomer with common bus-bar rated 300 Amp at incoming end of outgoing MCCBs grouted/ flush to wall, complete all as directed by Engineer-in-charge. (Note : (i) Cost of Eye/bottle thimbles used MCCBs in VTPN 6 way shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth (iii) Connection of cable with VTPN shall be done through appropriate size of Al thimble incl disconnecting and taking down old unsv MCCB DB VTPN of any description.INCOMING:- (a) MCCB 200 Amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 25 KA -01 Nos (Ultimate breaking capacity ICs -Icu = 100 %) .OUT GOING:- (a) MCCB 63 amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 16 KA --- 06 Nos. |
| 8 | S&F MCCB , TPN, 240 Volt , 63 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCCB should be B curve as directed by engineer in charge) |
| 9 | S&F MCCB , TPN, 240 Volt , 100 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCCB should be B curve as directed by engineer in charge) |
| 10 | S&F MCB , SPN, 240 Volt , 40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCB should be B curve as directed by engineer in charge). |
| 11 | S&F MCB, single pole 240 volts 6 to 32 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: MCB should be B curve as directed by engineer in charge) |
| 12 | S&F in replacement of MCB TPN 100 AMPS 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on DB complete all as specified and directed. (DB will be measured and paid separately under respective items of BoQ) |
| 13 | MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B curve as directed by engineer in charge) |
| 14 | Supply and fixing in replacement of u/s metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall complete all as specified and directed. |
| 15 | Supply and fix DB box MCB protected socket PVC plastic base having MCB of suitable rating 20 amp C series complete all as specified and directed by engr-in-charge. |
| 16 | M & L for Sub main wiring with two single core 1.5 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit of suitable dia including 1.5 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 1.50 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 1.5 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 17 | M & L for Sub main wiring with two single core 2.5 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit of suitable dia including 2.5 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 2.50 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 2.5 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB |
| 18 | Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. Note1: Chasing, cementing work and pvc conduit measured and paid seperately.Note2 : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length). |
| 19 | Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. Note1: Chasing, cementing work and pvc conduit measured and paid seperately.Note2 : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length). |
| 20 | Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed.Note1: Chasing, cementing work and pvc conduit measured and paid seperately Note2: Two runs of 10 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length 2.Chasin and cementing work measured and paid seperately.). |
| 21 | Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm 2 core PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as specified and directed. Note1: Chasing, cementing work and pvc conduit measured and paid seperately.Note2 : four runs of 10 sqmm cable alongwith two run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length). |
| 22 | M&L in replacement of old/damaged earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. |
| 23 | Sheet metal enclosure suitable for fixing DB and Electric meter, factory made of size 60 x 60 x 18 cm made out of 2mm thick MS sheet with double door, sutiable locking arrangements, powder coated, cutting chasing in wall and fixing and making good as per existing surface complete including removing old one, complete all as specified. |
| 24 | M&L spray Painting to existing sheet metal Enclosures for DB and Electric meter of any type complete with two coat of weather proof synthetic enamel paint over a coat of red oxide primer complete all as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 25 | M&L spray Painting to existing sheet metal Enclosures for DB and Electric meter of any type complete with two coat of weather proof synthetic enamel paint over a coat of red oxide primer complete all as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |