| 1 | PART - I - PROVN OF WINDOW GRILLS AT FIRST & SECOND FLOOR IN BLDG NO P-70 AND P-63 IN TECH AREA AT OD AVADI |
| 2 | Taking down of Aluminium chowkhat with shutters of any description exc 1 Sqm & nexc 3 Sqm, beading replacement, renewal of builders hardware fittings and adjusting, refixing in the same opening with fillers in gap complete all as specified and as directed. Note : Broken Glasses were measured and paid separately |
| 3 | M & L for forming Jambs etc to openings (to forgoings items) incl cutting, toothing and properly bonding into old work also facing, jointing and pointing to match existing work in CM 1:6 complete all as specified and as directed |
| 4 | M&L for preparation of new Jamb surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed. |
| 5 | M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer in charge. |
| 6 | M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and as directed by Engineer in charge. |
| 7 | Hacking out old broken glass (any size, quality or description) from metal frames, glazing with putting or beads complete all as specified and as directed |
| 8 | S & F of 4mm thick Sheet glass, ordinary quality and and glazing with oil putty in square n exc 0.5 sq. m in each pane and sheet glass is ground or obscured or frosted, on one side complete all as specified and as directed by Engineer in charge. |
| 9 | PART - II - PROVN OF MOSQUITO MESH DOOR & VENTILATORS IN DGQA GUEST HOME HVF ESTATE UNDER GE AVADI |
| 10 | S & F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 11 | S & F powder coated anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws, etc. complete all as specified & directed. |
| 12 | S&F for 4.0 mm thick figured glass pin headed type and glazing with oil putty for ventilator/windows in squares exc 0.5 sqm in each pane complete all as specified and as directed. |
| 13 | S&F Stainless steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 14 | S&F aluminium door closer hydraulically regulated designation No. 3 universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg & fixed complete all as specified & directed. |
| 15 | S&F aluminium rebated mortice lock vertical type size 100mm four lever complete all as specified & directed. |
| 16 | S&F floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and as directed. |
| 17 | PART - III - PROVN OF ROOF COVER OPENING ON FIRST WING 'B' OF HQ DQA (CV) UNDER GE AVADI |
| 18 | Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise having Superficial Area N exc 100 Sqcm for 10 CM depth of roof slab and reinforcement is cut through complete all as specified & directed . |
| 19 | M & L for cement concrete type B0 1:2:4 (12.5mm graded aggregates) in Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified & directed . |
| 20 | S & F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS1161-1979 grade St.-240 complete all as specified & as directed. |
| 21 | S & F of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and complete all as directed. |
| 22 | S & F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and complete all as directed. |
| 23 | M & L for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as directed. |
| 24 | Supply and fixing of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed. |
| 25 | Supply and fixing of PVC (SWR) bends any radius suitable for 110mm bore PVC pipes with access door complete all as specified and as directed. |
| 26 | S & F of Plain, galvanised, mild steel sheeting, 0.50mm thick of any colour in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 as specified and complete all as directed. |
| 27 | PART - IV - SPECIAL REPAIR/ REPLACEMENT OF 05 NOS AIR CONDITIONERS, 02 NOS WATER COOLERS AND 07 NOS STABLIZERS AGAINST BER DQA (CV) AVADI |
| 28 | Disconnecting electric supply from electric sources, taking down split/ window AC of any capacity with voltage stablzier without damaging any tother eqpts and making good and mitching with existing surface complete and incld transporatation to EMS store yard GE Avadi with all accessories. |
| 29 | Supply and Install Hi wall split Air Conditioner 1.5 TR capacity with Indoor, outdoor units complete cordless remote control unit and with in-built ioniser and plasma filter for better indoor air quality with minium 5 star rating and EER 3.2 ( Copper Condenser Coil) |
| 30 | Supply and fixing of GI powder coated brackets 16SWG for fixing of split Acs out door unit and including grouting with suitable size fastners complete. |
| 31 | Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input varition between 90V to 260V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 4KVA all as specified and as directed. |
| 32 | Supply and fix copper tubing set 1/4\\" and 1/2\\" suitable for Split AC including PUF insulation and connected accessories, fixcing for outdoor unit for user requirement complete all as directed by eng-in-charge |
| 33 | Supply and installation of Self contained drinking water cooler with(Non CFC Refrigerent) Energy efficient compressor cooling cap minimum 40 ltr/Hr, storage type, storage capacity minimum 80 ltrs, fully stainless steel (FSS) tank & body and with 2 Nos SS water taps & collection tray complete, suitable for operation on electric driven single phase 230 Volts , 50 c/s and as per I.S. specification complete . |
| 34 | Supply and fix voltage steblizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 V to 300 V with output voltage stabilised at 230 volts with accuracy of ± 2.5% and of capacity 3 KVA |
| 35 | Supply and laying in replaclement of UPVC pipes 20 mm dia of pressure rating 10 KG/Sqcm laid in trench complete including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc laid in trenches including taking down the old rusted pipe and testing complete all as specified and as directed. |
| 36 | Supply and fix in replacement for 20 mm bore dia UPVC gate valve (brass insert) complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 37 | Supply and fix in replacement for 20 mm bore dia UPVC gate valve (brass insert) complete all as specified and as directed. Please Enable Macros to View BoQ information |