| 1 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed. |
| 2 | M & L for point wiring with two runs of 1.5 Sqmm (nominal area) PVC insulated,FRLSH sheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20/25mm dia and its accessories fixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for :-(a) One light point controlled by one switch. |
| 3 | (b) One Ceiling fan point controlled by one switch and regulator |
| 4 | (c) One Exhaust fan/wall mounted fan point controlled by one switch. |
| 5 | (d) One 3 pin 5 amps socket point on same board |
| 6 | (e) One 3 pin 5 amps socket point on independent board |
| 7 | (f) One bell / buzzer point controlled by one bell push |
| 8 | M & L for point wiring with two runs of 4 Sqmm (nominal area) PVC insulated,FRLSH sheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20/25mm dia and its accessories fixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified and directed. |
| 9 | M&L for Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade sheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly complete all as specified for the following:- (Note : Cost of suitable size/module, Modular terminal box, Modular inner,outer cover plate and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring).(a) one light point controlled by one switch. |
| 10 | (b) One ceiling fan point controlled by one switch and regulator |
| 11 | (c) One Exhaust fan point controlled by one switch. |
| 12 | (d) One bell / buzzer point controlled by one bell push |
| 13 | (e) One switch socket outlet 3 pin 5 Amps on same board along with other switches |
| 14 | (f) One switch socket outlet 3 pin 5 Amps on independent board. |
| 15 | M&L for Point wiring on stone / brick masonry wall complete with two 4 sqmm single core PVC insulated FRLSH ,1100 volts grade sheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 4 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly complete all as specified for one 3/5 pin switch socket outlet, 5/15 Amps complete all as specified. (Note : Cost of suitable size/module, Modular terminal box, Modular inner,outer cover plate and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring). |
| 16 | M&L Pointing wiring in Existing conduit with two runs of 1.5 Sqmm (nominal area) PVC insulated,(FRLSH) sheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existing PVC/ steel heavy duty conduit 20 mm dia conduit including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, replaced with 3 mm thick laminated hylam sheet top cover for one light/fan/Bell/5 Amp socket all as specified and directed. |
| 17 | M&L Pointing wiring in Existing conduit with two runs of 4 Sqmm (nominal area) PVC insulated,(FRLSH) sheathed, multistranded, 1100 volts grade copper conductor cable single core, drawn through existing PVC/ steel heavy duty conduit 20 mm dia conduit including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, replaced with 3 mm thick laminated hylam sheet top cover for 15Amps socket all as specified and directed. |
| 18 | M&L for replacement of laminated hylam sheet top cover with brass screws, cup wahser suitable for 03/04 modules (switches,sockets etc.,) concealed box and cutting of grooves for switchs,sockets and regulator etc complete all as specified and directed.(Note: 1. Rates deemed to be included for removing and refixing of electrical point connections in switch board complete. 2. Switch,sockets,regulators to be measured and paid separately) |
| 19 | All as per above item description here-in- before but 06 to 10 modules complete all as specified and directed. |
| 20 | All as per above item description here-in- before but 18 to 24 modules complete all as specified and directed. |
| 21 | S&F in replacement of concealed metal GI box 10 to 16 modules (accommodated for switches, sockets,regulators etc.,) having high durability,corrosion resistant,earthing terminal with repalcement of modular type inner and outer plate covers with screws,incl all cutting/chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed. (Note:1. Rates deemed to be included for Modular type inner & outer cover plates complete and removing,refixing of electrical point connections in switch board complete. 2. Modular switch,sockets, regulators, bell push to be measured and paid separately) |
| 22 | All as per above item description here-in- before but 06/08 modules complete all as specified and directed. |
| 23 | All as per above item description here-in- before but 03/04 modules complete all as specified and directed. |
| 24 | All as per above item description here-in- before but 01/02 modules complete all as specified and directed. |
| 25 | S&F in replacement of concealed metal GI box 10 to 16 modules (accommodated for switches, sockets,regulators etc.,) having high durability,corrosion resistant,earthing terminal with incl all cutting/chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed. (Note:1. Rates deemed to be included for removing and refixing of electrical point connections in switch board complete. 2. Switch,sockets,regulators,bell push to be measured and paid separately) |
| 26 | All as per above item description here-in- before but 06/08 modules complete all as specified and directed. |
| 27 | All as per above item description here-in- before but 03/04 modules complete all as specified and directed. |
| 28 | All as per above item description here-in- before but 01/02 modules complete all as specified and directed. |
| 29 | S&F Switch piano flush type, single pole,5 Amps complete all specified. |
| 30 | S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all specified. |
| 31 | S&F Switch socket 3 pin 16 Amps, multipurpose, flush type complete all specified. |
| 32 | S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified. |
| 33 | S&F stepped type electronic fan regulator, flush type phenolic laminated sheet etc complete all as specified. |
| 34 | S&F Bell push, flush type, single pole, 5 Amps, 240 volts complete all specified. |
| 35 | S&F modular switch 6 Amps, one way, one module complete all as specified and directed. |
| 36 | S&F modular socket, 2/3 pin 6 Amps, 2 module complete all as specified and directed. |
| 37 | S&F modular switch 16 A, 1 module, complete all as specified and directed. |
| 38 | S&F modular socket 6/16 A, 5/6 pin, 2 module, complete all as specified and directed. |
| 39 | S&F modular Bell push 6 Amps, one module complete all as specified and directed. |
| 40 | S&F modular fan regulator step type complete all as specified and directed. |
| 41 | S &F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified. |
| 42 | S&F Bell , ding-dong type , AC, 230 volts, 50 HZ complete all as specified. |
| 43 | S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified. |
| 44 | S&F of LED tube light fitting 20/22 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis including taking down old light complete all as specified and directed. |
| 45 | S&F of LED tube light fitting 9/10 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all fixing accessoreis including taking down old light complete all as specified and directed. |
| 46 | S&F of LED Bulb 12/15 watt, B-22 base suitable for operation on AC, single phase complete including taking down old bulb complete all as specified and directed. |
| 47 | Supply and fix Decorative ECO bulkhead luminaire capacity 10/12W, environmental friendly ultra modern energy saving surface mounted, LED luminaire comprising of high brightness and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ including taking down fitting complete all as specified and directed. |
| 48 | Supply and fix LED building security light 45 W, made up of pressure die cast housing with toughed glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 incuding drivers, connecter block etc complete pre wired & connecting up with suitable twin core flexble copper wire and suitable bracket all as per dirtected including taking down old light complete all as specified. |
| 49 | Supply and fix Emergency energy saving LED Bulb 9 watt with back up up to 3 to 4 hrs, B-22 base suitable for operation on AC, single phase including taking down old bulb complete all as specified and directed. |
| 50 | Supply and fix Decorative LED wall light fitting, made out of polycarbonate suitable for incl B-22 base 10 Watt LED bulb fixed on wall including taking down old light complete all as specified and directed. |
| 51 | S&F in replacement of Recess mounting LED backlite panel ceiling light environmental friendly aesthetically designed recess mounting luminaire with high brightness LED luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 30/34 Watt LED (2'X2'), CDL/Warm type complete with electronic driver, suitable for operation on AC, single phase , 220 V, including provision of suitable twin core copper conductor PVC insulated , 1100 Volts grade cables connecting up ceiling rose and fittings and testing ,all as specified and as directed. |
| 52 | S&F in replacement of surface mounting LED backlite panel ceiling light environmental friendly aesthetically designed recess mounting luminaire with high brightness LED luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 30/34 Watt LED (2'X2'), CDL/Warm type complete with electronic driver, suitable for operation on AC, single phase , 220 V, including provision of suitable twin core copper conductor PVC insulated , 1100 Volts grade cables connecting up ceiling rose and fittings and testing ,all as specified and as directed. |
| 53 | S&F Surface and wall mounted LED tube light fitting, 20 W, batten type, extruded channel thermally conductive material, integrated motion sensor type wih electronic driver complete with all accessories , suitable for operation on AC, single phase 220 / 230 Volts , 50 Hz supply, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed. |
| 54 | S&F in replacement of surface/recess mounting LED backlite panel ceiling light environmental friendly aesthetically designed recess mounting luminaire with high brightness LED luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 30/34 Watt LED (2'X2'), CDL/Warm motion sensor type complete with electronic driver, suitable for operation on AC, single phase , 220 V, including provision of suitable twin core copper conductor PVC insulated , 1100 Volts grade cables connecting up ceiling rose and fittings and testing ,all as specified and as directed. |
| 55 | S&F in replacement of recess/surface mounting LED down lights aesthetically designed luminaire suitable for armstrong/grid ceiling complete for low ceiling applications 12/15 Watt LED ftg, CDL/Warm type complete with electronic driver, suitable for operation on AC, single phase , 220 V, including provision of suitable twin core copper conductor PVC insulated , 1100 Volts grade cables connecting up ceiling rose and fittings and testing ,all as specified and as directed. |
| 56 | S&F in replacement of Flood light luminaries LED energy saving 50 Watt, LED exlusive innovative designed, long life versatile pressure die-cast aluminium IP 65 flood light with high pressure die cast aluminium housing and impact resistant polycarbonate lens complete with all accessories and glass cover with suitable bracket or with grouted spring pressure fasterner/steel rawal plugs as directed including connection from juction box to lilght fittings with suitable twin core PVC insulated and unsheather, multi stranded FRLS copper conductor cable drawn in flexible conduit complete all specified and directed |
| 57 | S&F in replacement of Flood light luminaries LED energy saving 100 Watt, LED exlusive innovative designed, long life versatile pressure die-cast aluminium IP 65 flood light with high pressure die cast aluminium housing and impact resistant polycarbonate lens complete with all accessories and glass cover with suitable bracket or with grouted spring pressure fasterner/steel rawal plugs as directed by Engineer in Charge including connection from juction box to lilght fittings with suitable twin core PVC insulated and sheathed, multi stranded FRLS copper conductor cable drawn in flexible conduit complete all as specified and directed |
| 58 | Supply and Fixing of Rigid non-metallic PVC conduit for 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc with suitable TV socket box complete all as specified and directed. |
| 59 | Power / Sub-main wiring with PVC insulated sheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 2.5 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 2.5 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on walls ceiling / roof trusses etc with fixing accessories complete and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed. |
| 60 | Power / Sub-main wiring with PVC insulated sheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 4 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on walls ceiling / roof trusses etc with fixing accessories complete and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed. |
| 61 | Power / Sub-main wiring with PVC insulated sheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on walls ceiling / roof trusses etc with fixing accessories complete and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and as directed. |
| 62 | Power / Sub-main wiring with PVC insulated sheathed, FRLSH ,1100 volts, grade multistranded copper conductor, four runs of single core 10 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 10 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on wall/ ceiling / roof trusses etc. and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories complete all as specified and directed. |
| 63 | S&F in replacement of MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items. |
| 64 | S&F in replacement of MCB DB SPN 4 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items. |
| 65 | S&F in replacement of MCB DB TPN 4 way, distribution DB double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for TPN MCB 63 Amps as incomer and SP MCBs 40 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCB and Outgoing MCB measured separately relevent items. |
| 66 | S&F in replacement of Vertical Load line DB TP&N 4 way, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 100 Amps as incomer and SP MCBs 40 / 63 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items. |
| 67 | S&F for factory made sheet metal enclosure box of suitable size(not less than 50x45x12 cm) for fixing of load lines DBs/TPN DBs outdoor type vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated openable door, locking arrangement fixed on wall semi flush and making good the wall and match with the existing complete after taking down the unsv complete all as specified and directed. |
| 68 | S&F in replacement of 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified. |
| 69 | S&F in replacement of 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 to 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified. |
| 70 | S&F in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN and current carrying capacity 40-100 Amp in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 71 | S&F in replacement of MCCBs 63 Amps 415V,16KA, 4 Pole complete all as specified and directed. |
| 72 | S&F in replacement of MCCBs100 Amps 415V,16KA, 4 Pole complete all as specified and directed. |
| 73 | Rectifying faults by attending faults of point/sub main wiring complaints (excluding fittings and fixtures) any rating/ make/ model/ type in position including testing of serviceability of point wiring, finding of fault/ defect and repairing, jointing of wires/ cables properly with required jointing materials and making wiring functional etc., complete; all as specified and directed.Note:- (i) The rate quoted is deemed to be inclusive of cost of the required materials like insulation tape etc where required.(ii) Provn of point/sub main wiring, switch, socket accessories will be paid under relavent items. (iii) Contractor or his accredited Engineer/ representative shall collect the list of daily complaints from Complaint Cell.(iv) Contractor shall submit the daily list of all rectified/ non-rectified complaints to the Engineer-in-charge at the end of the day's work on each working day of unit/ AGE's office. |
| 74 | M&L for taking down and refixing carefully the ceiling fan of size/ make after disconnecting electric connections, including labour for servicing by greasing, Oiling, minor repairs and replacement of unserviceable/ rusted spares such as cotter pins, split pins,rubber wheel bearing washers,bushes, and connected hardware, and testing for proper operation after refixing, complete all as specified and directed. Note: (i) Rewinding of fan motor and replacement of major electrical components such as capacitors, stators, or bearings shall be measured and paid for seperately under relevant items. (ii) All replaced parts shall be handed over to the Engineer-in-Charge unless otherwise directed. |
| 75 | M&L for taking down and refixing carefully the Exhaust fan of size/ make after disconnecting electric connections, including labour for servicing by greasing, Oiling, minor repairs and replacement of unserviceable/ rusted spares such as cotter pins, split pins,rubber wheel bearing washers,bushes, and connected hardware, and testing for proper operation after refixing, complete all as specified and directed. Note: (i) Rewinding of fan motor and replacement of major electrical components such as capacitors, stators, or bearings shall be measured and paid for seperately under relevant items. (ii) All replaced parts shall be handed over to the Engineer-in-Charge unless otherwise directed. |
| 76 | M&L for taking down and refixing carefully the Wall mounted fan/Air circulator fan/ Pedestial fan of size/ make after disconnecting electric connections, including labour for servicing by greasing, Oiling, minor repairs and replacement of unserviceable/ rusted spares such as cotter pins, split pins,rubber wheel bearing washers,bushes, and connected hardware, and testing for proper operation after refixing, complete all as specified and directed. Note: (i) Rewinding of fan motor and replacement of major electrical components such as capacitors, stators, or bearings shall be measured and paid for seperately under relevant items. (ii) All replaced parts shall be handed over to the Engineer-in-Charge unless otherwise directed. |
| 77 | Material and Labour for painting of ceiling fans of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces complete including writing SM/MES No. in synthetic enamel paint (Black colour) over the same surface where the existing No. was written etc., all as specified and as directed. |
| 78 | Material and Labour for painting of Exhaust fan of any sweep to obtain even, smooth & glossy finish, with synthetic enamel paint of approved colour by using paint spraying devices after filling cavities with filler after cleaning all dust etc., over fan surfaces complete including writing SM/MES No. in synthetic enamel paint (colour as approved) over the same surface where the existing No. was written etc., all as specified and as directed. |
| 79 | Material and Labour for rewinding of fan motor with super enameled copper winding wire of same gauge and weight after cutting and removing the existing burnt/heated up windings, including cleaning of rotor, stator and varnishing, heating and providing fresh insulating materials for Ceiling fan of 1200/1400 mm sweep including dismantling and reassembling of fan motor complete all as specified and directed. |
| 80 | All as per above Item herein before but for Exhaust fan 200 to 300 mm sweep complete all as specified and directed. |
| 81 | All as per above Item herein before but for Exhaust fan 350 to 450 mm sweep complete all as specified and directed. |
| 82 | All as per above Item herein before but for wall mounted/Air circulator fan of any sweep/model complete all as specified and directed. |
| 83 | Supply only ball bearing suitable for ceiling fan of size 1200/1400mm sweep complete all as specified and directed. |
| 84 | Supply only ball bearing suitable for exhaust/wall mounted/Air circulator fan of any size and make complete all as specified and directed. |
| 85 | Replacement of old/unserviceable capacitor of capacity 2.5 µfd for the fans in position as complete all as specified and directed. |
| 86 | Replacement of old/unserviceable capacitor of capacity 4 µfd for the fans in position complete all as specified and directed. |
| 87 | Supply and fix in replacement of ventilation fan(plastic body) motors suitable for 200/250mm sweep complete all as specified and directed. |
| 88 | Supply and fix PVC canopy/Ceiling fan cap with fixing screws etc suitable for ceiling fan 1200/1400mm sweep etc., complete all as specified and as directed |
| 89 | Supply and fix ceiling fan blade with fixing accesories etc suitable for ceiling fan 1200/1400 mm sweep etc., complete all as specified and as directed |
| 90 | Supply and fix exhuast fan blade (metal body) with fixing accessories etc suitable for exhaust fan 300/480 mm sweep etc., complete all as specified and as directed |
| 91 | Supply and fix Air circulator fan blade (metal body) with fixing accessories suitable for 450 to 600 mm sweep etc., complete all as specified and as directed |
| 92 | Supply and fix exhuast fan louver (shutter) metal body with fixing accessories etc suitable for exhaust fan 300mm sweep etc., complete all as specified and as directed |
| 93 | M&L for ventilation fan blade (PVC type) suitable for 200/250 mm sweep complete all as specified and directed. |
| 94 | S&F in replacement louvers with shutter plastic body suitable for single phase 240 Volts ventilation fan 200/250 mm sweep with necessary fixing accessories after taking down existing complete all as specified and directed.. |
| 95 | Supply and fixing in replacement of 200 mm dia, 900 RPM, fresh air fan with plastic louvers, frame incl necessary alteration for fixing of fan in exist window as per site requirement complete all as specified and directed. |
| 96 | Supply and Fix ceiling fans down rods fabricated out of 15 mm dia GI pipe medium grade duly cutting/ threading/ drilling etc. Suitable for ceiling fans (1200/1400 mm sweep) fixed by means of check nut and split pin, 'U' clamp bolts, nuts, washers, rubber split pin check nut etc., complete all as specified and as directed. |
| 97 | M&L for making hole for fixing of exhaust/ventilation fan size 200 mm to 380 mm with necessary civil work as per site requirement complete make good the wall/ventilation window match with exist complete all as specified and directed. |
| 98 | M&L for taking down existing un serviceable and refxing with new check nut and split pin including 'U' clamp bolts, nuts, washers, rubber split pin check nut etc.,complete from ceiling fan 1200/1400 mm sweep etc.,all as specified and as directed. |
| 99 | Fixing arrangment of Air circulator fans with iron channels/Walls with suitable clamps, nut and bolts etc.,incl necessary welding works as per site requirement complete all as speccified and directed. |
| 100 | Supply and Fix ceiling fan hook made out of 40 x 6 mm MS flat iron and 10 dia MS round bar bend to shape for hanging ceiling fans including taking down existing unserviceable fan hook complete all as specified and as directed. |
| 101 | S&F in replacement of LED light fitting 1x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 102 | S&F Switch flame proof rotary type with termination box in LM6, 10/16A, single pole 240V complete all as specified and directed. |
| 103 | M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) complete all as specified and directed. |
| 104 | Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire complete all as specified and directed. Please Enable Macros to View BoQ information |