| 1 | Excavation in trenches not exc. 1.5 mtr wide and depth not exc. 1.5 mtr for foundation, laying GI pipes and UG cables etc not exc 10 sqmtr on plan, in soft/loose soil and getting out complete all as specified and directed. |
| 2 | All as per Item No.1.00 above but exc 1.5 m and not exc 2.00 m in deep and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 4 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 5 | Supply and laying 50 mm outside dia double wall corrugated pipe (DWC pipes SN-8) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. |
| 6 | Supply and laying 75 mm outside dia double wall corrugated pipe (DWC pipes SN-8) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. |
| 7 | Materials and labour for GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed. |
| 8 | Materials and labour for GI tubing of 50 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed. |
| 9 | Materials and labour for GI tubing of 80 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed. |
| 10 | Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 120 sqmm 3.5 core inclusive of cable lugs of suitable size including taking down old unserviceable cable and making necessery connections all as specified and as directed. |
| 11 | All as item no 10.00 above but of size of cable 95 sqmm 3.5 core |
| 12 | All as item no 10.00 above but of size of cable 70 sqmm 3.5 core |
| 13 | All as item no 10.00 above but of size of cable 50 sqmm 3.5 core |
| 14 | All as item no 10.00 above but of size of cable 35 sqmm 3.5 core |
| 15 | All as item no 10.00 above but of size of cable 25 sqmm 4 core |
| 16 | All as item no 10.00 above but of size of cable 16 sqmm 4 core |
| 17 | All as item no 10.00 above but of size of cable 16 sqmm 2 core |
| 18 | All as item no 10.00 above but of size of cable 10 sqmm 4 core |
| 19 | All as item no 10.00 above but of size of cable 10 sqmm 2 core |
| 20 | Supply and fixing Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-31 (9 metre long) including taking down old unserviceable RCC pole complete all as specified and directed. |
| 21 | Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint heat shrink type, complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately) |
| 22 | Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint heat shrink type, complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 70 to 185 Sqmm, complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately) |
| 23 | Materials and labour for PCC, type C1, (1:3:6), using 20mm graded crushed stone aggregated, as in foundation of poles, panels etc. with necessary formwork including demolition of old damaged concrete from pole complete all as specified and as directed |
| 24 | Materials and labour PCC, type D2, (1:4:8), using 40mm graded crushed stone aggregated, as in PCC on road cutting /installation area and foundation of pole etc complete all as specified and as directed. |
| 25 | Materials and labour for boring holes 1mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items). |
| 26 | Supply and fixing in repair Indicator lamp (AC/DC), LED, type for as per existing fitting.complete all as specified and as directed by Engr-in-Charge. |
| 27 | Supply and fixing in repair 3 Phase LED Ammeter complete all as specified and as directed by Engr-in-Charge. |
| 28 | Supply and fixing in repair, 3 phase LED Voltmeter complete all as specified and as directed by Engr-in-Charge. |
| 29 | Supply and fixing as in repairs MCCB four pole , 415 Volt, 63 Amps,16 KA , fixed thermal & magnetic release including spreader link complete all as specified and directed |
| 30 | Supply and fixing as in repairs MCCB four pole , 415 Volt, 100 Amps,16 KA , fixed thermal & magnetic release including spreader link complete all as specified and directed |
| 31 | Supply and fixing as in repairs MCCB four pole , 415 Volt, 125 Amps,16 KA , fixed thermal & magnetic release including spreader link complete all as specified and directed |
| 32 | Supply and fixing MCCB, 160 Amps, 4P, 16 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link complete including taking down old unserviceable MCCB complete all as specified and as directed. . |
| 33 | Supply and fixing MCCB, 200 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link complete including taking down old unserviceable MCCB complete all as specified and as directed. |
| 34 | Supply and fixing MCCB, 250 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link complete including taking down old unserviceable MCCB complete all as specified and as directed. |
| 35 | Supply and fixing MCCB, 400 Amps, 4P, 36 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release including spreader link complete including taking down old unserviceable MCCB complete all as specified and as directed. |
| 36 | Material and labour for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 25 X 4mm GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.Note: The earth resistance value shall be less than 3 Ohm and test report shall be submitted to the department. |
| 37 | Material and labour for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.Note: The earth resistance value shall be less than 3 Ohm and test report shall be submitted to the department. |
| 38 | Materials and labour for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. |
| 39 | Supply and fixing thermoplastic polycarbonate cable junction box having IP 66 protection, dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size upto 25 sqmm and of size 195x155x100mm with terminals, brackets, cable lugs of size upto 25 sqmm for max 4 cable entry for street light pole mounting and provision of one 6A MCB SP all as specified and as directed. |
| 40 | Supply and fixing thermoplastic polycarbonate cable junction box having IP 66 protection, dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size upto 25 sqmm and of size 295x195x100mm with terminals, brackets, cable lugs of size upto 25 sqmm for max 4 cable entry for street light pole mounting and provision of one 6A MCB SP all as specified and as directed. |
| 41 | Materials and labour for painting old painted LT Panel/feeder pillar by two coats of synthetic enamel paint after preparation of surfaces complete all as specified and as directed. |
| 42 | Servicing of LT Panel after shut down and removing all dust particles and proper layout of LT panel wlth gland packing including 2.5 sqmm copper single core copper cable including repairing/replacing door hinges/door lock etc amd for necessary connections complete all as specified and directed |
| 43 | Materials and labour for Preparation of metalic surface with sand paper for street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge |
| 44 | Materials and labour for aluminium paint two coats on newly primed metalic surface of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge |
| 45 | Materials and labour for two coats of Yellow/black synthetic enamel paint on metalic surface complete all as specified and as directed by Engr- in-Charge |
| 46 | Materials and labour for preparation of old decorated concrete/plastered surfaces and applying two coats of Cement based paint complete all as specified and as directed by Engr- in-Charge |
| 47 | Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure complete all as specified including providing, fixing and connecting following accessories of approved make :- Incoming :- (i) Aluminium busbar rating 400 Amps rating- 4 Nos. (minimum width and thickness 50x10mm) (ii) MCCB 250 Amps 4 pole breaking capacity 25 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit pro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 160 Amps 4 pole 02 No, MCCB 100 Amp 4 pole 02 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 Nos, Digital Voltmeter with in built selector switch -01 Nos and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Sets |
| 48 | Supply, installing, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure complete all as specified including providing, fixing and connecting following accessories of approved make :- Incoming :- (i) Aluminium busbar rating 250 Amps rating 4 Nos. (ii) MCCB 160 Amps 4 pole breaking capacity 25 KA thermal mag protection with ICS = ISU100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuit pro-tection having positive insulation, Spreader Link -01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 01 No, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, thermal mag protection with Icu = 100% & rated impulse withstand voltage (Vimp) 8 KV with over current & short circuit protection having double insulation & positive insulation. (ii) MCB SPN 20 Amps-06 Nos.(iv) Current transformer 100/5Amps class-1 15 VA - 1 No, Digital Ammeter with inbuilt selector switch -01 Nos, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Sets (at both incomer MCCB) |
| 49 | Supply and fixing in repair CPRI approved street light panel of suitable dimension outdoor type, powder coated,dust and vermin proof IP-55,prewired , operates on three phase made with 3.15mm thick CRCA sheet, framing with 50x50x6mm thick MS angle, legs of 45cm long fixed in PCC (1:3:6) 100mm thick platform (upto 1m alround), slanting roof, suitable locking arrangement duly painted both internally and externally with powder coating paint in heat process having auto/manual selector switch, connecting incoming/outgoing cable with suitable size of lugs and comprising the following.Incoming :- (i) Aluminium busbar rating 150 Amps rating- 4 Nos. (ii) MCCB 100 Amps 4 pole 415 volts, breaking capacity 25 KA adjustable thermal and adjustable magnetic protection including fixing accessories -01 No.Outgoing :-(i) MCCB 40 Amp 4 pole 415 volts, breaking capacity 10 KA, adjustable thermal and fixed magnetic protection including fixing accessories -02 Nos. (ii) MCB SPN 20 Amps-05 Nos. (iii) MCB SPN 10 Amps-05 Nos.(iv) Digital Ammeter with inbuilt selector switch -01 Nos, (v) LED type red indicator lamp -03 Nos. |
| 50 | Taking down existing faulty LT UG cable line 1100V of any size from existing location and relaying serviceable portion of LT UG cable after necessary repair work at fault location, providing joints etc. if required all as specified and as directed(Note: Items required for repair, joint and excavation works will be measured and paid separately under relevant items. Only serviceable portion relayed shall be measured for payment) |
| 51 | Taking out old bricks/cable cover and relaying after cable repair work complete all as specified and as directed. |
| 52 | Materials and labour for marking Street light pole/Panel numbers with black colour synthetic enamel paint including all connecting items complete all as specified and as directed by the Engineer in Charge. |
| 53 | Supply and fixing danger notice plate of size 25x20cm of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skul and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 complete as directed by the Engineer in Charge. |
| 54 | Supply and fixing in repair CPRI approved bus bar panel of suitable dimension outdoor type, powder coated,dust and vermin proof IP-55,prewired , operates on three phase made with 3.15mm thick CRCA sheet with locking arrangement duly painted with minimum four numbers of Aluminium bus bar having current rating 400 Amps with arrangement for two incoming and 4 outgoing cables including foundation using PCC (1:2:4) work complete all as specified and as directed by Engineer in Charge. |
| 55 | Supply and fixing in repair 8 KW ,three phase automatic Street Light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor overload protection fuse gear, power contactor & MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole/Wall mountable elcosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 with universal lock and key arrangement complete all as specified and as directed by Engr- in- Charge Make: kakatiya energy system Pvt Ltd Cat No. Swadeep 66-02EC-8KW 3P or equivalent in Havells/GE |
| 56 | Materials and labour for coping of poles by using PCC, type C1, (1:3:6, using 20mm graded stone aggregates) as in including formwork for any type of poles including painting two coats of cement paint complete all as specified and as directed including demolition of old damaged concrete from pole complete all as specified and directed. Please Enable Macros to View BoQ information |