| 1 | SCH 'A' PART-I To XIINote: This schedule is pre-priced by MES and the rate indicated under Col 5 signifies this fact only |
| 2 | Total amount of Sch 'A' Part-I (Building and Structures) |
| 3 | Total amount of Sch 'A' Part-II (Site Clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch 'A' Part-III (Internal Water Supply) |
| 5 | Total amount of Sch 'A' Part-IV (Internal Electric Supply) |
| 6 | Total amount of Sch 'A' Part-V (Road, Paths & Culverts ) |
| 7 | Total amount of Sch 'A' Part-VI (Sewage Disposal) |
| 8 | Total amount of Sch 'A' Part-VII (Area Drainage) |
| 9 | Total amount of Sch 'A' Part-VIII (Compound wall, Fencing and Gate) |
| 10 | Total amount of Sch 'A' Part-IX (Hot Water Supply) |
| 11 | Total amount of Sch 'A' Part-X (External Water Supply) |
| 12 | Total amount of Sch 'A' Part-XI (External Electric Supply) |
| 13 | Total amount of Sch 'A' Part-XII (Rain Water Harvesting) |
| 14 | SCHEDULE 'A' PART-XIII (MISCELLANEOUS B/R AND E/M WORKS) |
| 15 | S&F fancy type, 15 mm dia, Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as specified and directed. |
| 16 | S&F MCCB, 4P, AC, 415 Volts of 63 Amp capacity 16 KA, thermal and magnetic adjustable Ics=100% Icu, and making connections with suitable size of copper lugs etc complete all as specified and directed. |
| 17 | S&F LED Tube light fitting 20 W extruded aluminium housing battens are equipped with lumen efficiency pg 100LM/W and milky white, special polycarbonate diffuser, for glare free efficient light distribution with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed. |
| 18 | S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitting 10 Watt with uniform light output, with all accessories including its connection with 2 core sheathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed. |
| 19 | S&F energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V, 50 HZ etc complete all as specified and directed. |
| 20 | S&F Exhaust fan, PVC body AC single Phase. 230V of size 300 mm sweep with blades, and frame and louvers complete all as specified and directed. |
| 21 | S &F Modular TV Socket 1 module including PVC Conduit pipe concealed in wall of suitable dia, complete all as specified and directed by Engineer-in- charge |
| 22 | M&L Preparation of new black top surfaces and painting lines, dashes, letter, arrows etc of any width or girth on road pavement and like with 2mm thick ness thermoplastic road marking paint white or golden yellow with glass reflectorised beads applied mechanically with thermoplastic applicator machines all as manufactures instructions and complete all as specified and directed |
| 23 | M&L for dismantling old chamber and Construction of PCC solid block valve chamber including earth work described as under complete all as specified for the internal Dimension 1200 mm x 1200 mm x 1000 mm as under : (a)100 mm thick hard core (b)PCC foundation 1:4:8 type D2 (using 40 mm graded stone aggregate) (c) 200 mm thick block masonry graded C-5 built in CM 1:6, (d)15 mm internal and external plaster in CM 1:4 (e)3mm thick MS sheet chamber cover and 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface including locking arrangements, complete all as specified and as directed. |
| 24 | Supply and fixing Ductile Iron (DI) fittings for flanged pipes of 100 mm to 250 mm bore, including bends, tapers, tee pieces (single and double branch) of any type, angle or radius, and straight connecting pieces, all ends flanged, complete with necessary bolts, nuts, rubber gaskets and jointing material, complete all as specified and as directed by the Engineer-in-Charge |
| 25 | Cutting existing cast iron (CI) pipe / galvanised iron (GI) tubing of 100 mm, 150 mm, 200 mm and 250 mm diameter in position for taking out new connections, including insertion of new tees, branches, etc., complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | Drilling and tapping cast iron (CI) / ductile iron (DI) water mains in position for providing branch connections of 50 mm internal diameter, including all necessary fittings, jointing materials and making good, complete all as specified and as directed by the Engineer-in-Charge. |
| 27 | Supply, lowering and fixing open well submersible pump set suitable for 380/415 V, 3 phase, 50 Hz AC supply, of 3.0 HP capacity, having outlet size 50 mm, head range 37 metres and discharge 150 LPM, including suitable foundation, necessary fittings, accessories, electrical connections, testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge. |
| 28 | Supply and fixing Direct-On-Line (DOL) starter with control panel for 3.0 HP open well submersible pump set, suitable for 415 V, 3 phase, 50 Hz AC supply, including all internal wiring, contactor, overload relay, push buttons, indicators, enclosure, and connections, complete all as specified and as directed by the Engineer-in-Charge. |
| 29 | Material and labour for cast iron (CI) / ductile iron (DI) special fittings such as bends of any type, radius and angle, tapers of any type, straight pieces, increasing/decreasing pieces, double socket pieces, tail pieces, single branch, ‘Y’ junctions, double branch, crosses (all socket or socket and spigot), collars, caps and plugs, etc., suitable for CI/DI pipes (Class LA) up to 300 mm bore, complete with jointing materials, complete all as specified and as directed by the Engineer-in-Charge. |
| 30 | Supply and fixing mechanical joints (non-expandable type) for CI/DI pipes of 150 mm bore, complete with rubber rings, nuts, bolts, washers and all necessary jointing materials, complete all as specified and as directed by the Engineer-in-Charge. |
| 31 | Supply and fixing mechanical joints (non-expandable type) for CI/DI pipes of 200 mm bore, complete with rubber rings, nuts, bolts, washers and all necessary jointing materials, complete all as specified and as directed by the Engineer-in-Charge. |
| 32 | Supply and laying ductile iron pipes with Spigot and socket ends centrifugally K-7 , in any length, laid in trenches for following pipes of dia complete all as specified and as directed. NOTE: Tyton joints required are deemed to be included in the unit rate quoted. |
| 33 | 150mm bore |
| 34 | 200mm bore |
| 35 | Supply and Installation of Smart RF Three Phase Meter with the following specifications:(a) AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to 15-16444 and relevant IEC standards with inbuilt cellular communication facility with self healing Mesh network with default and ·on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.(b) Meter should support sending the following data: 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software.(c) Meter should have connect/ disconnect functionality operable from billing software.(d) The meter should support open communication protocol DLMS with the software.MAKE: L&T (cat part no WR300BC73LPR6) or equivalent in Secure or Schneider.Notes:(1) Meters would have 5 years OEM Warranty(2) Data Concentrator Units (DCU) & Web based Software module and connected accessories is considered in new work projected for complete stn. |
| 36 | Supply & laying of DWC HDPE pipe ISI mark of outer dia 50 mm polyethylene with smooth internal and profiled external surface for non pressure under ground cable including coupler and bends etc complete all as specified and directed |
| 37 | Supply & laying of DWC HDPE pipe ISI mark of outer dia 120 mm polyethylene with smooth internal and profiled external surface for non pressure under ground cable including coupler and bends etc complete all as specified and directed. |
| 38 | Supply, Installation, Testing and Commissioning of step down transformer, outdoor type, and conforming to IS 1180:2014, plinth mounted, HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN - 11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus (-) 7.5% to plus (+) 7.5% in steps of 2.5%, continuous rating of capacity 100 KVA Level 3 including Cable entry box on HT Side, Cable entry box on LT side. The Transformer shall be completed with all standard fittings and accessories and first fill of transformer oil IS 335 ISI marked filtered & dehydrated oil etc, complete all as specified and directed and comprising of the following accessories :- |
| 39 | Note - Transformer shall be mounted on platform/plinth.(a) One cable entry box on primary HV side having cable glands suitable for HT XLPE Cable (consisting of 3 Nos porcelain HT bushings with brass/gun metal bushing rods complete with nuts and washers).(b) One cable entry box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No cable gland suitable for reception of outgoing LT armoured cables of suitable size.(c) Oil conservator tank with filter type, drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Thermometer pocket on tank cover.(f) One No 100mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device.(g) Rating plate with terminal markings.(h) Two earthing terminals on tank/tank cover to facilitate fixing of 32x6m GI earth strip.(j) Oil Level gauge.(k) Oil drain and filter valves.(l) Oil filler hole with cap/plug with connections complete.(m) Lifting lugs.(n) Air relief valve plug.(o) Four plan solid cast steel detachable rollers.(p) First fill of fresh oil conforming to relevant IS and tested upto 50 KV dielectric strength upto top of core.(q) Extra bushing for neutral outside the LT cable box for providing independent earthing for neutral.(s) Any other fittings/accessories so as to confirm the whole transformer to IS-1180 Part-1:2014. |
| 40 | Supply,installation,testing and commissioining factory made L T feeder pillar panel CPRI approved, size of panel as per CPRI specification, double door floor mounted outdoor type, as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body of suitable size with aluminium bus bar 300 Amps, 4 strip,(3 phase & Neutral) complete drifled,insufated with colour coded insulation tape,mounted on insulators etc with RYB indicater, internal wiring with suitable size of copper wire,panel should be dust proof, vermin proof, powder coated, locking should be screw type,mechanical type,inter focking,should have danger notice for 415 volt, AC Mounted on 50 x50 x6 mm angle iron framehaving minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) type B-1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs and glands Nuts & Bolts, complete all as specified and directed.(Incoming(a) MCCB, 125 Amps adjustable type, with breaking cap 50KA - 01 Nos (Ics=100% Icu))(b) Digital maltifunction meter with CT- 01 No.(c) Indicating lamp LED type one set in incoming phases.(d) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs.(e) Connection from MCCB to Busbar shall be of solid Aluminium conductor. |
| 41 | (f) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable.(g) KWH meter CT operated as per suitable capacity of L T Panel.Outgoing ways :- (a) MCCB 63 Amps adjudtable type ,4 pole,25 KA- 02 Nos (lcs=100%Icu)(b) MCCB 32 Amps adjudtable type ,4 pole, 16 KA- 01 Nos (lcs=100%Icu) |
| 42 | Supply and fix HT 11 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting rotating type comolete with droo out fuse havina 12 insulators of ratina uoto 200 Amps, complete all as specified and directed. |
| 43 | M &L for construction of plinth (of size 3000mm x 3000 mm x 1500 mm) including excavation in trenchs in any type of soil, PCC 1:4:8 in foundation fly ash bricks machinary in cement mortor 1:6 ,filling with moorum inside the plinth and RCC 1:2:4 over plinth including 16 mm bar reinforcement with center to centre distane 100mm and external surface of masonary shall be plasterd with cement mortar 1:4 and painted withweather coat paint (double coat paint) of shade complete all as specified and directed by Engr in charge |
| 44 | M&L Street Light Fitting Bracket made out from Gl Pipe 40 mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works, complete all as specified and directed. |
| 45 | S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 200 x 175 x100 mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size MildSteel Bolts, Nuts & Washers, etc, complete all as specified and directed. |
| 46 | S &F PCC Cable route Indicator with suitable reinforcement of size 50 x10 x10 cm with letter inscribed on both side as \\"MES LT CABLE \\" of specified front side not less than 30mm as directed and mounted on PCC 40x30x30 cm complete using PCC 1:2:4 B-1 using 20mm graded stone aggregate and applying two coat of cement base paint, complete all as specified and directed. |
| 47 | S &F PCC Cable route Indicator with suitable reinforcement of size 50x10x10 cm with letter inscribed on both side as \\"MES HT CABLE \\" of specified front side not less than 30mm as directed and mounted on PCC 40x30x30 cm complete using PCC 1:2:4 B-1 using 20mm graded stone aggregate and applying two coat of cement base paint, complete all as specified and directed. |
| 48 | Supply and fixing of 40 Amp time light DB with TP 40 Amps mcb at in comer with 40 Amp AC3 duty contractor along with design as per IEC 61439, material and CRCA sheet up to 12 mm with Astronomical time switch complete prewired IP 55 protection auto manual selector switch for auto manual operation,power indicator and 2 Amp fuse for protection of time switch,input output terminal block of termination of input output cable with gland special provision of incorporation of under voltage over voltage relay for protection of incorporated contractor coil,including the cost of labour charges for erecting on pole /walls/panel including clamps,nut bolts to complete the job up to as directed by Engineer in Charge. |
| 49 | Taking out existing HT cable from trench, including careful excavation, removal without damage, recoiling, and depositing the same in MES store yard, complete all as specified and as directed by the Engineer-in-Charge. |
| 50 | Supply and fix facory made HT Feeder pilfer box 11 KV,3 Phase 350 MVA Aluminium bus bar and installed CT &. PT for measuring voltage & current with voltmeter and Ammeter mounted on 11 KV Porceline post insulator/epoxy insulator including one coat of primer and two coat of enamel paint testing ,Commisssioning complete with grouting in PPC 1 :3:6 type C2 on plinth of size 1200 x 1200 x1 000 including one incoming and two outgoing suitable for 3 core XLPE armoured aluminium conductor cable of suitable size with including plinth as specified by Engr-in-Charge. Please Enable Macros to View BoQ information |