| 1 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in Channels, angles, tees and flats complete all as specified and directed. |
| 2 | Demolition of cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) complete all as specified and directed. |
| 3 | Demolition of brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge built In cement mortar complete all as specified and directed. |
| 4 | Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars complete all as specified and directed. |
| 5 | S&F Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required, In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, complete all as specified and directed. |
| 6 | M&L for Finishing Painting Two or more coats on new work with synthetic enamel paint of approved brand and manufacture to give an even shade of required shade complete all as specified and directed. |
| 7 | Earth work in excavation of any type soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, complete all as specified and directed. |
| 8 | Returning Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m complete all as specified and directed. |
| 9 | Disposal of surplus soil/moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 10 | M&L PCC 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) PCC in foundations, filling and mass-concrete complete all as specified and directed. |
| 11 | M&L Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). |
| 12 | Providing and laying in position ready mixed or site batched design mix Concrete of M-25 grade with minimum cement content of 330 kg /cum cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete All works above plinth level upto floor V level: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete complete all as specified and directed. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Colum ,struts , Lintels, beams, plinth beams, girders, bressumers and cantilevers complete all as specified and directed. |
| 15 | M&L for TMT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto plinth level complete all as specified and directed. |
| 16 | M&L TMT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level complete all as specified and directed. |
| 17 | M&L for Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and directed. |
| 18 | M&L for 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) complete all as specified and directed. |
| 19 | M&L for Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour complete all as specified and directed. |
| 20 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia etc complete all as specified and directed. |
| 21 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) complete all as specified and directed. |
| 22 | M&L for Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used with G.I. barbed wire complete all as specified and directed. |
| 23 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red complete all as specified and directed. |
| 24 | Providing and laying factory made chamfered edge Cement Concrete paver blocks 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 25 | Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed.Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations |
| 26 | Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.Note: Only punned thickness shall be measured and paid. |
| 27 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with flat, size 300 mm x 180mm x 40mm complete all as specified and directed by Engineer-in-Charge. |
| 28 | Fixing / laying only old PCC cable cover of any description as obtained from dismantling of the cable complete all as specified and directed by the Engineer-in-Charge. |
| 29 | Taking down/disconnecting the existing LT/HT cable of any type and any size from boundary wall/trench complete all as specified and directed . |
| 30 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 150 sq mm complete, all as specified and directed. |
| 31 | Supply and fix cable jointing kit for 11 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 150 Sqmm 3 core XLPE, armoured, AI conductor cable Indoor/Outdoor type complete all as specified and directed by Engr-in-Charge. |
| 32 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete, all as specified and directed by Engr-in-Charge. |
| 33 | Supply & fixing 2 way SPN DB single door type Suitable for surface and flush mounting. IP 43 with metal door complete all as specified and directed by Engr-in-Charge. |
| 34 | Supply and fixing SP 6 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning, all as specified and directed by Engr-in-Charge. |
| 35 | S&F submain wiring alongwith earth continuity conductor with PVC insulated FR multistranded copper conductor cable (Phase- Red, Neutral - Black, Earth - Green) in PVC conduit drawing into and including concealed rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories of nominal size of 2x2.5 sqmm + 1x2.5 sqmm earth wire in suitable size of conduit complete all as specified and directed. |
| 36 | Supplying & laying GI water tubing, light grade of size 40 mm dia as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of lantern/ street light fitting complete all as specified and directed. |
| 37 | Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |