| 1 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed. |
| 2 | Material and labour for Point wiring with 2 Run of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit medium grade not less than 20 mm dia with accessories/ casing caping, concealed/surface type on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including sunken pressed steel terminal boxes (modular type, size/modules as required at site) with and including screws, modular cover plate over sunken box for housing the modular switches, socket outlet. Supply and fixing in replacement of regulators etc and making good the disturbed surfaces as per existing for :- One light point/bell/fan point controlled by one switch complete all as specified and directed.Note:- 1. Modular metal flush/sunken Box, and for modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 2. Switch, socket and fan regulators to be measured and paid separately. |
| 3 | All as per Srl Item No. 02.00 here-in-before but One 3 pin socket point 5 Amps on independent board. |
| 4 | All as per Srl Item No. 02.00 here-in-before but One 3 pin socket point 5 Amps on same board. |
| 5 | All as per Srl Item No. 02.00 here-in-before but for one socket point 15 Amp with 2.5 sq mm PVC unsheathed FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.5 sq mm green colour FRLS-H, 1100 volt grade ISI marked copper wire as earth continuity conductor connected to common earth dolly . |
| 6 | All as per Srl Item No. 02.00 here-in-before but for one socket point 15 Amp/AC box with 4 sq mm PVC unsheathed FRLS, 1100 volt grade ISI marked, multi stranded copper conductor along with 4 sq mm green colour FRLS, 1100 volt grade ISI marked copper wire as earth continuity conductor connected to common earth dolly. |
| 7 | Material and labour for replacement of modular switch 6 Amp 1 way 1 module 230 volts complete all as specified and directed. |
| 8 | Material and labour for replacement of switch modular 16 Amp 1 way 1 module 230 voltscomplete all as specified and directed. |
| 9 | Material and labour for replacement of socket modular 2/3 pin 5 Amp 2 module 230 volts complete all as specified and directed. |
| 10 | Material and labour for replacement of socket modular 2/3 pin 6/16 Amp 2 module 230 volts complete all as specified and directed. |
| 11 | Material and labour for replacement of electronic Fan regulator modular 100 watt 1/2 module complete all as specified and directed. |
| 12 | Material and labour for replacement of ceiling rose surface type 2/3 terminal complete all as specified and directed. |
| 13 | Material and labour for replacement of lamp holder, insulated body, with back plate for angular batten fittings complete all as specified and directed. |
| 14 | Material and labour for replacement of LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and directed. |
| 15 | Material and labour for replacement of Lumiline Plus LED batten tube light fitting 20 watt, 4 feet long, wall mounted box type, opal diffuser, high efficient aluminum housing body, high efficient, AC 220-240 volts, complete all as specified and directed. |
| 16 | Material and labour for replacement of DECORATIVE LED MIRROR light 6/7/8/9 watt 3 in one color wall mounted PVC body (color decided by engr in charge) including driver complete all as specified and directed. |
| 17 | Material and labour for replacement of LED Midnight Wall light round shaped (Bulkhead) 12W 6000K surface mounted bulk head luminaries including driver & LED etc complete with all accessories complete all as specified and directed. |
| 18 | Material and labour for replacement of decorative wall light, stainless steel, rust free fixture with white glass diffuser suitable for 7.5/9 watt LED, 240 volt, 50HZ, AC supply complete with all accessories complete all as specified and directed. |
| 19 | Material and labour for replacement of LED Building security light fitting 35 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment, including GI pipe bracket and suitable hole fastner complete all as specified and directed. |
| 20 | Material and labour for replacement of ultra slim LED flat panel 2' x 2' size surface/ recess mounted (grid/ gypsum type) 36-40 watt , warm/cool white with provision of PVC flexible copper conductor cable to light fitting complete all as specified and directed. |
| 21 | Material and labour for replacement of LED Inverted pyramid tripod type Bollard with soft 360 degree light distribution 10 watt , IP-65 rated , 240 volt, 50HZ, AC supply, having metalic base complete with all accessories including PCC 1:3:6 of size 400x400x400 mm including necessary form work complete all as specified and directed. |
| 22 | Material and labour for replacement of ultra slim LED circular downlighter recess mounted (false ceiling grid/ gypsum type) 9/10 watt watt, warm/cool white complete all as specified and directed. |
| 23 | Material and labour for replacement of LED post top luminaire 30-35W IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with fitting and including fitting & provision of 3 core PVC flexible copper conductor from Electric Supply Source to connector of the light complete all as specified and directed. |
| 24 | Material and labour for decorative Rope light warm white Low power consumption, Safe and Reliable for beautification, Long Life and Perfect as per requirement. 1 unit of 50 mtr roll would have adaptor & end cap attached to the strip & 10 clamps would be included. LED Rope Light: 6W per Meter AC Strip Light for prefect ambience.Waterproof with IP65 site rating, for superior life and withstanding harsh weather.including two extra adopter per 50 mtr roll for easier connection as per requirement complete all as specified and directed. Note :- Cost of two extra adopter is inclusive in the unit cost. |
| 25 | Material and labour for replacement of 55W Smart LED Strip – High brightness with 240 LEDs per meter Bright White Light – Perfect for functional and decorative illumination.Flexible 5M Roll – Easy to cut and install for customized setups.Smart Home Compatible – Works with WiFi for remote control and automation.Energy Efficient & Long-Lasting – Saves power while ensuring durability.Versatile Use – Ideal for homes, offices, retail displays, parties, and décor complete all as specified and directed. |
| 26 | Material and labour for Decorative hanging light having metalic canopy, pendant mounting ,having hight adjustable string, color decided by Engr in Charge, consist of pin type bulb of 10 watt complete all as specified and directed |
| 27 | Material and labour for decorative 7 watt two way LED light having aluminium housing wall mounted complete all as specified and directed. |
| 28 | Material and labour for Melody Music Remote Control Door Bell 32 Musical Sound Cordless Doorbell With 32 Melody Music Lines Grace, Light Touch Button complete all as specified and directed. |
| 29 | Material and labour for replacement of single pole and neutral enclosure with two pin and earth plug and socket 20 Amp complete with and including one single pole MCB. 20 Amp in enclosure complete all as specified and directed. |
| 30 | Material and labour for replacement of sheet metal MCB DBs 4 way with 200 Amps rated bus bar single pole and neutral, IP-43, double door fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth disturbed surface after r complete all as specified and directed. |
| 31 | Material and labour for replacement of sheet metal MCB DBs 8 way with 200 Amps rated bus bar single pole and neutral IP-43, doubel door fixed on wall duly grouted in solid block wall or on wooden board, including copper lugs/thimbles duly crimped for connection, including making smooth disturbed surface complete all as specified and directed. |
| 32 | Supply and fixing in replacement of sheet metal MCB DBs 12 way with 200 Amps rated bus bar single pole and neutral IP-43, doubel door fixed on wall duly grouted in solid block wall or on wooden board, including copper lugs/thimbles duly crimped for connection, including making smooth disturbed surface complete all as specified and directed. |
| 33 | Material and labour for replacement of sheet metal enclosure Vertical triple pole & neutral(VTPN) with MCCB TPN 125 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface complete all as specified and directed. |
| 34 | Material and labour for replacement of sheet metal enclosure Vertical triple pole & neutral(VTPN) with MCCB TPN 63 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface after removing old unserviceable VTPN complete all as specified and directed. |
| 35 | Material and labour for replacement of MCB SP 6-32 Amps, 240 volt,10 KA 'C' curve i complete all as specified and directed. |
| 36 | Material and labour for replacement of MCB SPN 32/40 Amps, 240 volt,10 KA 'C' curve complete all as specified and directed. |
| 37 | Material and labour for replacement of sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked multi stranded copper conductor with one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor connected to common earth dolly including capping & casing or concealed on wall/ceiling in PVC conduit medium grade not less than 25 mm dia ISI marked of adequate size for housing the wires complete all as specified and directed.Note :- (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB (ii) For the purpose of payment two runs of 6 sqmm conductors and one run of 6 sqmm conductor with conduit shall be measured as one length of one RM. |
| 38 | Material and labour for replacement of sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked multi stranded copper conductor with one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor connected to common earth dolly including capping & casing or concealed on wall/ceiling in PVC conduit medium grade not less than 25 mm dia ISI marked of adequate size for housing the wires complete all as specified and directed.Note :- (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB (ii) For the purpose of payment two runs of 4 sqmm conductors and one run of 4 sqmm conductor with conduit shall be measured as one length of one RM. |
| 39 | Supply, laying, fixing or passing through pipe 1100 volts grade heavy duty 2 core, 6 sq mm cable with PVC insulated, multi stranded aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and directed. |
| 40 | Supply, laying, fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm cable with PVC insulated, multi stranded aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and directed. |
| 41 | Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the same XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as specified and directed. Note :- Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately . Please Enable Macros to View BoQ information |
| 42 | Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the same XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as specified and directed. Note :- Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately . Please Enable Macros to View BoQ information |