| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (Code No. 15.56) |
| 2 | 12 MM Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.. (Code No. 13.9.1) |
| 3 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.For the purpose of measurement the entire treated surface will be measured. ( Code No. 22.6) |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below (Code No. 15.12.1) |
| 5 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or leaner mix (i/c equivalent design mix) |
| 8 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 10 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 11 | Supplying & fixing 24 gauge annodized aluminium sheet of approved quality including cutting, wastage and fixing the same over the wooden door shutters with nails with all material, labour and T&P. (CSI No. 8.60) |
| 12 | Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. |
| 13 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 14 | 12 mm cement plaster of mix 1:6 (1cement:6coarse sand) lumsum |
| 15 | 12 mm cement plaster of mix 1:4 (1cement:4coarse sand) |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(Code No.13.80) |
| 17 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 18 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 19 | Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38) |
| 20 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. |
| 21 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 22 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989 |
| 23 | Supply and fixing of Single Concealed stop cock with basin spout (Composite one piece body) Jaquar make model no-FLR-5441NK . The work includes cost of all labour, material T&P for proper completion of work |
| 24 | S/F of Jaquar make pillar cock of model of FLR-5011N as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work |
| 25 | S/F of Jaquar make long body Bib Cock of model no CON-107PM as per direction of engineer in charge. This include cost of labour, material T&P etc for proper completion of work. |
| 26 | Supply and fixing of Angular stop cock of \\"Jaguar\\" make or equivalent Model No-FUS-29053as approved by E/I. This include cost of labour, material T&P etc. for proper completion of work. |
| 27 | Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. 110 mm Dia |
| 28 | Cleaning panes of glass with spirit of caustic soda including supply of all materials,labour and T&P etc.required for proper completion of the work. (CSI No. 20.09) |
| 29 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 30 | Steel work welded in built up sections/ framed work, In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (Code No. 10.25.2) |
| 31 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.00 mm thick glass panes(Code No. 10.30.1) |
| 32 | Cement concrete 40 mm thick with 20 mm nominal size stone aggregate flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (Code No. 11.3.1) |
| 33 | Providing and fixing glass strips in 40 mm wide and 4 mm thick joints of terrazo/ cement concrete floors.(Code No. 11.13.1) |
| 34 | Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. (CSI No.11.18)(NSI NO. 35) |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work(Code No. 13.99.1) |
| 36 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 37 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect |
| 38 | Wiring for circuit/ submain wiring with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR E&M 2022 1.14.2) |
| 39 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) |
| 40 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 41 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3) (Code No. 27.01) |
| 42 | Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) |
| 43 | Supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.12.1)(Code No. 27.12) |
| 44 | Supply Installation, Testing and Commissioning of 1200mm sweep, BEE 5 Star rated, ceiling fan with Brush less Direct Current (BLDC) Motor, class of Insulation: B, 3 nos blades,30cm long down rod,2 nos canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00 Air delivery minimum 210 Cum/min 350 RPM (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise-75 degree C (MAX.) INSULATION RESISTANCE MORE THAN 2 MEGA OHM. SUITABLE FOR 230v, 50Hz. Songle phase AC supply, earthing etc. complete as required (DSR E&M 2022 |
| 45 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.300 mm dia(Code No. 23.1.1.1) |
| 46 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level..300 mm dia (Code No. 23.2.1.1) |
| 47 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.100 mm nominal size dia(Code No. 23.4.1) |
| 48 | Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. (CSI No. 19.28)(NSI No. 52) |
| 49 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia(Code No. 23.3.1) |
| 50 | Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge.3240 (40 mm OD) pipe (Code No. 18.1.5) |
| 51 | Supplying and drawing following 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(DSR E&M 2022 1.17.12) (Code No. 27.22) |
| 52 | Supply & Installation of 2 HP outlet 40mm dia. or more, Head 71/36, Discharge 2000/6000 LPH submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32)c (NSI Sl. No.56)c) 2 HP outlet 40mm dia. or more, Head 89/45, Discharge 2000/6000 LPH |
| 53 | Supply & installation of 1.5/ 2 H.P pump set single phase electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31)b (NSI Sl. No.55) |
| 54 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (Code No.23.8) |
| 55 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.(Code No. 23.12) |
| 56 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Code No. 18.48) |
| 57 | Providing and laying SWR, PVC 110 mm Dia ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29c) NSI Sl. No.110 |
| 58 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal dia Pipes pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.. (Code No. 18.8.2) |
| 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 25 mm nominal dia Pipes pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.. (Code No. 18.8.3) |
| 60 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore (Code No. 18.17.1) |
| 61 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 62 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 63 | FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete . |
| 64 | Construction of boundary wall with Precast Column and Pannel (with prestressed concrete , pannel size-2100x300x50mm and column size 150x150x2400mm ,1800 mm. above and 600mm. below ground level) including fixing of pannel & column in proper alignment including cost of all material labour and T&P etc. required for proper complection of work as per direction of engineer incharge . (C.C. for grouting, excavation of pit and P.C.C. shall be paid extra) . (NSI). |
| 65 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 66 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 67 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 68 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 69 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 70 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 71 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 72 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 73 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 74 | Providing (12x15) mm section groove in plaster including all material, labour and T&P etc. required for proper completion of the work. (CSI No. 11.16) Please Enable Macros to View BoQ information |