| 1 | PART A (CIVIL WORKS) FOR RESIDENTIAL COLONY AND TOWNSHIP (without ITC) |
| 2 | PART B (ELECTRICAL WORKS) FOR RESIDENTIAL COLONY AND TOWNSHIP (without ITC) |
| 3 | PART A (CIVIL WORKS) FOR RESIDENTIAL COLONY AND TOWNSHIP (without ITC) |
| 4 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm |
| 5 | Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet : 250x130x30 mm |
| 6 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 7 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 8 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :Flat back wash basin of size 450x300 mm |
| 9 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mm |
| 10 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia |
| 11 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm dia |
| 12 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms |
| 13 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 14 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 15 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 16 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore |
| 17 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 18 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50mm nominal bore |
| 19 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 20 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length15 mm nominal bore |
| 21 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore |
| 22 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :25 mm nominal bore |
| 23 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm |
| 24 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size ) |
| 25 | Brick work with FALG bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 26 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 27 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 28 | Neat cement punning. |
| 29 | Renewal of old putty of glass panes (length) |
| 30 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats |
| 31 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 32 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 33 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore |
| 34 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore |
| 35 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore |
| 36 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 37 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 38 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 39 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : Above 40 mm nominal bore |
| 40 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 41 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size) |
| 42 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 100 mm diameter : Class I |
| 43 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 44 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 45 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 46 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 47 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in- Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 48 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 100x58x1.90 mm |
| 49 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 300 mm weighing not less than 200 grams |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 51 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :20 mm dia (heavy type) |
| 52 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 53 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 18 mm thick |
| 54 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood |
| 55 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm |
| 56 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 57 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 58 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding |
| 59 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore |
| 60 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :50 mm nominal bore |
| 61 | Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material: Beyond 30 cm girth upto and including 60 cm girth. |
| 62 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
| 63 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 64 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm |
| 65 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :100x10 mm |
| 66 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm |
| 67 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 68 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes |
| 69 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes |
| 70 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 71 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :40 mm nominal bore |
| 72 | Readjusting wash basin/sink. (including cost of all materials, nails etc. all complete as per direction of EIC) |
| 73 | Repair of flushing cistern. (including cost of all materials, nails etc. all complete as per direction of EIC) |
| 74 | Repair of gate latch. (including cost of all materials, nails etc. all complete as per direction of EIC) |
| 75 | Refixing mirror shelf. (including cost of all materials, nails etc. all complete as per direction of EIC) |
| 76 | Refixing mirror. (including cost of all materials, nails etc. all complete as per direction of EIC) |
| 77 | Readjusting brackets of curtain rod. (including cost of all materials, nails etc. all complete as per direction of EIC) |
| 78 | Repair of bib cock / change of washer. |
| 79 | Repair of piller cock / change of washer. |
| 80 | Repair of valve of all sizes |
| 81 | Repair of stop cock / change of washer. |
| 82 | Providing & fixing CP piller cock / change of washer. |
| 83 | Removing and refixing water supply pipe after cleaning it, all complete as per direction of EIC. Upto 40mm diametre. |
| 84 | Providing and fixing kota stone draining board including C.I brackets. ( fixing with 25mm kota stone beat arelite)The board shall have a fluted surface with smooth finish complete 600x450x25mm size. |
| 85 | Providing and fixing aluminium sheet 24 guage |
| 86 | Providing & fixing cover of PVC water tank |
| 87 | Easing & refixing charges for all sizes of window, Doors etc.( one carpenter and one helper for one day ) -Minimum four doors to be eased and refixed in a day |
| 88 | Repair of PVC water tanks |
| 89 | Providing& fixing G I bend/ elbow 15mm dia |
| 90 | Providing& fixing G I bend/ elbow- 25mm dia |
| 91 | Providing & fixing G.I sockets - 15mm |
| 92 | Providing & fixing G.I sockets - 25mm |
| 93 | Providing and fixing G.I tees - 15mm |
| 94 | Providing and fixing G.I tees - 25mm |
| 95 | Providing & fixing 100 MM foot valve for underground sump |
| 96 | Refixing/repairing of float valve for over head PVC water tank |
| 97 | Dismantling of WC pan of all types including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 98 | Work for trimming of big trees cutting of dead trees etc and collection and disposal of tree branches or waste materials by mechanical means, including loading, transporting, unloading to dumping ground beyond 50 m initial lead, for all leads including all lifts involved. desired by EIC to his satisfation. |
| 99 | Providing, laying and jointing unplasticised Rigid PVC pipes including testing of joints etc. complete as per instruction of EIC.: 150 mm diameter |
| 100 | Providing and fixing C.I. Bracket for wash basin and sinks. |
| 101 | Cleaning of open area inside colony compound wall & door to door collection of dry and wet garbage, emptying of dustbins from all 75 nos. of residential quarters including dumping of garbage at specified place inside the colony premises complete on daily basis as per instruction of EIC (One unskilled manpower every day). |
| 102 | Cleaning of storm water drains (i.e. main drains & individual drains of all 75 nos. quarters) of the entire colony including removing RCC covers where ever required and resetting the same including dumping of garbage at specified place inside the colony premises complete on weekly basis as per instrcution of Engineer-Incharge (One unskilled manpower every day). |
| 103 | Cleaning of colony roads, berms about 1200 meter everyday & cleaning, brooming, sweeping of 1No.Office, Cash room,store etc.including 1No. Toilet for Office including dumping of garbage at specified place inside the colony premises complete on daily basis as per instruction of Engineer-Incharge (one unskilled manpower every day). |
| 104 | Operating water supply pumps and operation of all valves of the pipelines and individual tanks properly inside colony premises on daily basis (in two shifts) in order to avoid wastage, overflowing etc.as per direction of EIC (Two semi-skilled manpower every day). |
| 105 | Cleaning of all sizes of water tanks once in a year for two years as per instruction of EIC. |
| 106 | Cleaning and desludging of septic tank of all sizes by mechanized means only (suction-cum-jetting machine / vacuum tanker), including opening of cover, removal of sludge and night soil, collection, transportation and safe disposal outside colony premises in leak-proof container, refixing of cover and sealing of joints with cement mortar (1:4), complete as per direction of Engineer-in-Charge. |
| 107 | Removal of blockage of Manhole/Inspection Chamber and sewer line by using Hydro-Ejector Machine (High Pressure Sewer Cleaning Unit), including jetting, suction, flushing and disposal of silt/sludge, complete as per direction of Engineer-in-Charge.Rate is inclusive of all cost of labour inclusive of minimum wages, tools and tackles, consumables, contractor profit etc in complete all respect. |
| 108 | Cleaning of underground reservoir twice in a year for two years as per instruction of EIC. |
| 109 | Disposal of dead animals including digging of pits & covering with earth etc as per direction of the authorised incharge of the work.Rate is inclusive of all cost of labour inclusive of minimum wages, tools and tackles, consumables, contractor profit etc in complete all respect: Dog. |
| 110 | Disposal of dead animals including digging of pits & covering with earth etc as per direction of the authorised incharge of the work.Rate is inclusive of all cost of labour inclusive of minimum wages, tools and tackles, consumables, contractor profit etc in complete all respect: Cat and Puppy. |
| 111 | Supply of materials (Qty. Of materials should be supplied proportianately average consumption per month):- |
| 112 | a. Detergent Powder |
| 113 | b. Seekh Jhadu |
| 114 | c. Mopping cloth |
| 115 | d. Bleaching powder |
| 116 | e. Toilet freshner/Odonil |
| 117 | f. Phool Jhadu |
| 118 | g. Phenyl White |
| 119 | h. Phenyl Black |
| 120 | i. Colin |
| 121 | j. Phenyl Goli |
| 122 | k. Duster |
| 123 | l. Liquied Hand wash |
| 124 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 125 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 126 | Carrying out anti mosquito & pest control inside residential complex, minimum one semi skilled manpower for colony on each working day for two years needs to be provided as per instruction of EIC : (a). Anti larval operation inside the colony for open catchment area and open drains with Barcelo twice in a month. (Total two operations in a month). (b). Mechanical spraying in residential / non residential units with Malathion 50 EC. One operation each in the month of June, Sept., December and March. (Total four operations in a year) including elimination of adult mosquito and pests such as Lizards,cockroach etc. (c). Mechanical spraying in residential/ non residential units with K-Othrine 2.5% flow. One operation each in the month of July, Oct., January and April. (Total four operations in a year) including elimination of adult mosquito and pests such as Lizards, cockroach etc. (d). Outdoor fogging, misting of non residential areas inside the colony premises with kingfog once in a week i.e Total four operations in a month.(e). Snake control treatment in each units with Carbolic acid during rainy season and as per requirment and instruction of EIC. (f). Rodent control treatment inside qtrs. with anticoagulate cake as per requirement and instruction of EIC. |
| 127 | Supply of Materials |
| 128 | a. Barcelo |
| 129 | b. Malathion |
| 130 | c. K-OTHIRINE |
| 131 | d. KING FOG |
| 132 | e. Anticoagulant cake |
| 133 | f. Carbolic acid |
| 134 | g. Disel |
| 135 | h. Petrol |
| 136 | Total impact of GST for the purpose of CTC |
| 137 | PART B (ELECTRICAL WORKS) FOR RESIDENTIAL COLONY AND TOWNSHIP (without ITC) |
| 138 | Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. |
| 139 | Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 140 | Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2x4 sq.mm + 1x4 sq.mm earth wire. |
| 141 | Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2x6 sq.mm + 1x6 sq.mm earth wire |
| 142 | Supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required. 3 x 1.5 sq.mm |
| 143 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required : 5/6 amps switch |
| 144 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required : 15/16 amps switch |
| 145 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required : 3 pin 5/6 amps socket outlet |
| 146 | Supplying and fixing piano/flush type switch/socket on the existing switch box/cover including connections etc. as required : 6 pin 15/16 amps socket outlet |
| 147 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. (each set consists 3 numbers). |
| 148 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 149 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 150 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. |
| 151 | Supplying and fixing of call bell/buzzer suitable for single phase, 230 volts, complete as required. |
| 152 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole |
| 153 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole and neutral |
| 154 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredTriple pole and neutral |
| 155 | Supplying and fixing PVC batten/ angle holder includingconnections etc. as required. |
| 156 | Supplying and fixing Bell push switch on the existing switch box/cover including connections etc. as required |
| 157 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 158 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 A |
| 159 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired.40 A |
| 160 | Providing and fixing 36 kA, 125 amps four pole rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc. as required . |
| 161 | Providing and fixing 36 kA, 250 amps four pole rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc. as required . |
| 162 | Providing and fixing 50 kA, 400 amps four pole rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc. as required . |
| 163 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required |
| 164 | Upto 35 sq. mm |
| 165 | Above 35 sq. mm and upto 95 sq. mm |
| 166 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. : Upto 35 sq. mm |
| 167 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 168 | 4X10SQMM (25 mm) |
| 169 | 4X16SQMM (28 mm) |
| 170 | 4 cx 25 sqmm (28 mm) |
| 171 | 4 cx 35 sqmm (32 mm) |
| 172 | 4 cx 50 sqmm(35 mm) |
| 173 | 3½ cx 70 sqmm(38 mm) |
| 174 | 3½ cx 95sqmm (45mm) |
| 175 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. : upto 120 sq mm |
| 176 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 70 sq. mm |
| 177 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 70 sq. mm |
| 178 | Supply and fixing of AL Lugs of different sizes : 25 sq.mm |
| 179 | Supply of AL Lugs of different sizes : 120 sq.mm |
| 180 | Supply and fixing Junction boxes/ Cable end boxes for 6 Way TPN DD DB (Out door) |
| 181 | Supply and fixing Junction boxes/ Cable end boxes for 4 Way TPN DD DB (Out door) with connector. |
| 182 | Supply and Fixing of 63 AMPS \\"c\\" series MCB TPN 440VOLTS, 10kAmps with connections, testing and commisioning etc as required for inductive loads TPN 63A |
| 183 | Supply and fixing of top 6 Amp. |
| 184 | Supply and fixing of top 16 amp. |
| 185 | Supply and fixing of following lamp/tube 07 watt LED lamp |
| 186 | Supply and fixing of on the existing board 15/16 Amps S/S combined |
| 187 | Supply and fixing of wooden board of different sizes with backelite sheet on top. 4\\"x4\\" |
| 188 | Supply and fixing of wooden board of different sizes with backelite sheet on top. 7\\"x4\\" |
| 189 | Supply and fixing of wooden board of different sizes with backelite sheet on top. 8\\"x6\\" |
| 190 | Supply and fixing of wooden board of different sizes with backelite sheet on top. 8\\"x10\\" |
| 191 | Supply and fixing of 24/20/25 Watt Batten LED Tube Light |
| 192 | Supply and fixing of 60 W LED street light |
| 193 | Supply and fixing of 48 W LED street light driver circuit |
| 194 | Repairing & Rewinding of Ceiling Fan including replacement of bearing/bush etc. as required, dismantling & fitting (24 months from 01.07.2026 to 30.06.2028) |
| 195 | Replacement of 2.5 mfd ceiling fan condenser (24 months from 01.07.2026 to 30.06.2028) |
| 196 | Repairing & Rewinding of Exhaust Fan(upto 300mm) including replacement of bearing/bush etc. as required, dismantling & fitting (24 months from 01.07.2026 to 30.06.2028) |
| 197 | Replacement of 5 mfd exhaust fan condenser (24 months from 01.07.2026 to 30.06.2028) |
| 198 | CAMC of RO water purifier in built with water cooler(50 ltr/ph) installed in camp-01 nos. (24 months from 01.07.2026 to 30.06.2028)Rs-20990.00 per machine per year |
| 199 | Comprehensive, AMC ,(without compresser)of 02 Nos. 2 TR Inverter Split AC’s installed atcamp.(24 months from 01.07.2026 to 30.06.2028) |
| 200 | a. AC Servicing with Jet Pump |
| 201 | b. Gas Charging R-32 |
| 202 | c. Voltas /Godrej Make Fan motor, fan blade replcement & fitting |
| 203 | d. Voltas /Godrej Make PCB Indoor and Outdoor replacement & fitting |
| 204 | Estimate of manpowers (one electrician and one khalasi ).for operation of camp substation,day to day electrical breakdown rectification works , maintenance of Electrical Installtions, cleaning of switchyard,Monthly tree trimming work in the campus, street lights checking and swicthing works etc as required time to time and other allied works as per the instruction of EIC/OIC (camp), at CMPDI, RI VI-6 camp office complex and township Singrauli(24 months from 01.07.2026 to 30.06.2028). |
| 205 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |