| 1 | Running & Maintenance of Internal Electrical Installations, External lighting and Maintenance of submersible pump at Open Playground at Qutubgarh Village as per inventory and Additional conditions enclosed the contractor shall depute following staff :i) 1 No Wiremen for 1 day in a week for 52 week as per direction of site incharge ii)1 No. Khallasi for 1 day in a week for 52 week as per direction of site incharge All tools and plants including tower wagon suitable to maintain fittings mounted up to height 12 mtrs. shall be made available at the site throughout the contract period. |
| 2 | Comprehensive (Semi) Annual Maintenance of 1 No. RO System 50 LPH capacity connected with water coolers i/c three mandatory services (cleaning of All Filters), repair/ replacement of all electrical and electronic spare parts and one time replacement of consumables once in a year like Particulate Filter 20” or (2 x 10”), Sediment Filter 20” or (2 x 10”), Pre Carbon Filter 20” and Post Carbon Filter 20” (except membranes), attending complaints within 24 working hours with complete overhauling and servicing etc. as required. Dismantle material retained to contracter. |
| 3 | Replacement of RO TFC Membrane 75 GPD i/c testing, commissioning etc. as required old dismantle shall be retained by the contractor |
| 4 | Extra Filters Required to be replaced after using its life to enhance the funcioning of the machines. i/c Leak testing, commissioning etc complete as reqd at site. old dismantle shall be retained by the contractor |
| 5 | 20\\" Particulate / Sediment Filter |
| 6 | Supply and replacement of 20'' pre filter spun 5 micron for RO system etc complete as required. |
| 7 | Supply and replacement of feed water pressure generating pump with automated switch for 50 LPH capacity RO system etc complete as required. |
| 8 | Supplying and fixing of Automated on/ off Switching Device for Level monitoring of Water cooler in existing 50 LPH RO at site. |
| 9 | Servicing of water cooler 150 ltr. Capacity oiling in fan motor, Cleaning of base plate and condenser coil with chemical and cleaning of water tank etc. complete as required. |
| 10 | Supply and replacement of following part in water cooler i/c connection, testing etc. complete as required |
| 11 | Thermostat |
| 12 | Over load protection with relay box |
| 13 | Float Valve Assembly |
| 14 | Water tap |
| 15 | Rewinding of fan motor suitable for 150 Ltr capacity water cooler i/c replacement of bushes, testing, commissioning etc. complete as require. |
| 16 | Service of following type air conditioner of 2.0 ton capacity i/c cleaning of cooling coil & condenser with chemical, washing the complete air-conditioner, painting of sheet metal parts hose plate with synthetic enamel i/c painting of exposed cooling & condenser pipes with anti corrosion paint, oiling of fan motor, etc as required. |
| 17 | split type |
| 18 | Supply and charging of refrigerant for 2.0 Ton capacity following type air conditioner of various make i/c testing of pressure and cooling etc. complete as required. |
| 19 | Split Type /Ref Charging |
| 20 | Repairing of PCB of Split type AC i/c connection, testing etc. complete as required. |
| 21 | Supplying and replacement of unserviceable pair of PCB for both indoor unit and out door unit of air conditioner, suitable for various make of 2 Ton inverter type air conditioner i.c connection,testing etc. complete as required. |
| 22 | Supply and fixing of CO2 type Fire Extinguisher of 4.5 Kg , Duly ISI marked conforming to IS: 15683, complete with delivery hose horn , wheel type release valve, locking arrangement, pressure gauge, operation manual and bracket etc. complete as required. |
| 23 | Supply and fixing of ABC type Fire Extinguisher of 5 Kg , CE Certified conforming to IS: 4308 , complete with delivery hose horn , wheel type release valve, locking arrangement, pressure gauge, operation manual and bracket etc. complete as required. |
| 24 | Lifting out of submersible pump set from the exiting bore well up to the required depth along-with existing G.I. pipes and accessories etc. i/c dismantling of G.I pipe and disconnecting the sub. cable etc. complete as reqd. |
| 25 | Lowering of sub. pump set in the existing bore well up to the required depth along with existing G.I pipe and sub. cableetc , water proof jointing of sub. cable. Replacement of reqd. nuts, bolts, washers and packing, nipple, reducer, connection testing, etc. complete as reqd. |
| 26 | Repairing and rewinding of Submersible motors of following capacity with cartage, dismantling, reassembling i/c supply & replacement/ repairing of all damaged parts of motors and making good for operation i/c connection, testing, painting etc. complete as required. |
| 27 | Upto 3 HP single/ three Phase Submersible motor |
| 28 | Supplying of sub. Pump set duly coupled with suitable rating Three phase, 415 volt, 50Hz, sub. Motor. The pump sets shall be suitable for the following duties. a) Head Range:- 6-55 Mtr. Discharge Range :-450-100 LPM. Minimum HP/Stage:- 3 HP/5 Stage. Outlet Size:-50 mm |
| 29 | Supplying of copper conductor flat submersible cable of following size i/c testing,connection etc. complete as reqd. |
| 30 | 3 x 2.5 sq.mm |
| 31 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. |
| 32 | 5/6 A switch |
| 33 | 15/16 A switch |
| 34 | 3 pin 5/6 A socket outlet |
| 35 | 6 pin 15/16 A socket outlet |
| 36 | Supplying of following MCB's for Electrical Panel Board/ feeder pillar/ pole including testing etc as required. |
| 37 | 6 to 32 Amp SP MCB \\"C\\" series. (10 KA Capacity) |
| 38 | 32 Amp DP MCB \\"C\\" series. (10 KA Capacity) |
| 39 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 40 | 100 A,30KA,FPMCCB |
| 41 | 200 A,36KA,FPMCCB |
| 42 | Supplying and Repalcement (including deduction of cost for replaced item) of PVC insulated copper wire of following size in the existing surface/ recessed conduit i/c connection, testing etc. as required. |
| 43 | 3 x 1.5 sq. mm |
| 44 | 3 x 2.5 sq. mm |
| 45 | 3 x 4 sq. mm |
| 46 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internalsurge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)36 watt |
| 47 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm18- 22 Watt Please Enable Macros to View BoQ information |