| 1 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2 | Earthwork in excavation by mechanical mens (Hydraulic excavator)/ manual means over areas(exceeding 30cm in depth, 1.5m width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by engineer-in-charge).All kinds of Soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc, in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for alllift. |
| 4 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 5 | Providing preconstructional antitermite treatment and creating and chemical barrier under and around the coloumn pits wall trenches bascement excavation top surface inplinth filling juction of wall and floor, along the external per meter of binding expansion joints surrounding of pipes and conduit etc. complete (plinth area of the building at ground floor only shall be measurd as per I.S. 6313(part Il 1981) Aldrine emulsifiable concentrate or any other approved material such as Hepthachlor of chlordance will be used. The rate of application of chemicalemulsion shall be as follows :-1) Treatment for massonary and foundation 5 litesper sqmBack fill in immediate contact with foundation7 .. 5 lites per sqm3) Treatment of surface of plinth filling 5 lites per sqmTreatment of soil along external permeter of4)and injecting chemical for2)Building 2.25 liter per linear meter of theperimetr wall5) Treatment of soil under external permeter 5lites per sqm |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level:1:4:8 derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) |
| 7 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works upto plinth levelConcrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 8 | All works above plinth level upto floor V LevelConcrete of M25 grade with minimum cementcontent of 330 kg /cum |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4(1 cement:4 coarse sand) |
| 10 | Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.MS AND Medium tensile steel bars |
| 11 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 12 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes |
| 13 | 15MM cement plaster on rought side of single or half brick wall of mix Total qty for Plaster Work |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 16 | Finishing walls with Premium Acrylic Smooth exterior paint with Siliconeadditives of required shade:New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 17 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 18 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 19 | Lock For Frameless toughened Glass as railling |
| 20 | Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc |
| 21 | Supply and Fixing of artificial grass on the top of slab of fountain |
| 22 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting andmaking good the walls etc. |
| 23 | Internal work – Exposed on wall. |
| 24 | 25 mm nominal outer dia Pipes |
| 25 | 32 mm nominal outer dia Pipes |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 27 | Concealed including cutting chases and making good the wall etc. |
| 28 | 32 mm nominal outer dia Pipes |
| 29 | 25 mm nominal outer dia Pipes |
| 30 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tappingthe main : |
| 31 | 25 mm nominal bore |
| 32 | 100mm fountain |
| 33 | 100mm fountain extension pipe |
| 34 | Heavy duty pvc suppling, laying in wall following sizes of heavy duty pvc pipes and covering with cement ctc. As required suppling and fixing of 100mm dia high pressure pvc pipe |
| 35 | 4 way brass elbow 25mm |
| 36 | 3 Way brass circuit |
| 37 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 38 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 39 | Providing and fixing of pump motor of 3 HP with wire |
| 40 | Providing and fixing of pump motor of 2 HP with wire |
| 41 | Submersible pump |
| 42 | Submersible bore |
| 43 | SILICON FOR WATER PROOFING |
| 44 | PLANT FOR GREENERY |
| 45 | ss main gate laser cutting |
| 46 | ss writing material cutting |
| 47 | security piller |
| 48 | Cost of Electrical Works as per Specification |
| 49 | Statue |
| 50 | 18% GST Please Enable Macros to View BoQ information |