| 1 | Lump Sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule 'A' Part-I |
| 2 | Lump Sum price worked out by the contractor for \\"INTERNAL ELECTRIC SUPPLY WORKS\\" as listed in Schedule 'A' Part-II |
| 3 | Lump Sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY WORKS\\" as listed in Schedule 'A' Part-III |
| 4 | Lump Sum price worked out by the contractor for \\"SEWAGE DISPOSAL WORKS\\" as listed in Schedule 'A' Part-IV |
| 5 | Lump Sum price worked out by the contractor for \\"AREA DRAINAGE WORKS\\" as listed in Schedule 'A' Part-V |
| 6 | Lump Sum price worked out by the contractor for \\"ROAD/ PATH/ HARD STANDING WORKS\\" as listed in Schedule 'A' Part-VI |
| 7 | Lump Sum price worked out by the contractor for \\"EXTERNAL ELECTRIC SUPPLY WORKS\\" as listed in Schedule 'A' Part-VII |
| 8 | Lump Sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY WORKS\\" as listed in Schedule 'A' Part-VIII |
| 9 | Lump Sum price worked out by the contractor for \\"PROTECTIVE WORKS\\" as listed in Schedule 'A' Part-IX |
| 10 | Lump Sum price worked out by the contractor for \\"GARBAGE BINS\\" as listed in Schedule 'A' Part-X |
| 11 | Lump Sum price worked out by the contractor for \\"SITE CLEARANCE, DEVELOPMENT AND EARTH WORKS (FOR PART-II TO PART-X)\\" as listed in Schedule 'A' Part-XI |
| 12 | Lump Sum price worked out by the contractor for \\"DEMOLITION AND DEMOLITION WORKS\\" as listed in Schedule 'A' Part-XII |
| 13 | Schedule 'A' Part- XIV (Misc Items) Note : This schedule is not pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only. |
| 14 | Misc items for Internal Electric Supply Works |
| 15 | Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable conforming to IS-694 of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly drawn in and including new concealed rigid PVC non metallic conduit terminated on and including new modular GI metal sunken box of thickness not less than 1.2 mm and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall including cutting chases (using electric driven cutter) in any type of wall complete, comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge.Note: cost of cutting chases and making good shall deemed to be included in the unit rate quoted against the item. |
| 16 | All as per Serial item No. 13.00 here-in-before but for one socket outlet 3/ 5 pin, 5 Amps on independent board complete all as specified and as directed by Engineer-in-Charge. |
| 17 | All as per Serial item No. 13.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge. |
| 18 | All as per Serial item No 13.00 here-in-before but for one socket outlet 3/5 pin, 15 Amps on independent board, size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge. |
| 19 | S&F Inverter type LED tube light batten 4 feet, 1 x 18/20 watt, 230 volts inbuilt Lithium ion battery with charging time 8 to 10 Hours and back up time minimum 4 Hours complete including fitting fixed on wall/ ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection complete all as specified and directed by Engineer-in-charge. |
| 20 | Supply and fixing LED Bulb, 09 Watt, ISI Marked complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 21 | Supply and fixing LED Bulb, 09 Watt, ISI Marked complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |