| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: Rural Engineering Wing Budgam Name of work :- Setting up of DDMA premises/ control room for Magistrates etc including civil works at Railway station Nowgam (civil Works only) Scheme: SANJY - 2026 Contract No: of 2026-27 DATED: Adv cost =Rs 5.26 LACS Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No. Item Description Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 3 | Providing and laying vitrified floor tiles in sizes 600x600mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete |
| 4 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Powder coated aluminum (minimum thickness of powder coated 50 microns). (JS 20102: 101.60 x 44.45 x 2.50 ) |
| 5 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Powder coated aluminum (minimum thickness of powder coated 50 microns). For shutters of doors, windows & ventilators ncluding providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required & all other accessories (Handles, Tower-Bolt, Al-Drop etc.) (Door Shutters: 85.00 x 44.45 x 2.70; Window Shutter: 50.00 x 44.50 x 2.50) |
| 6 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on both sides. |
| 7 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
| 8 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 9 | Finishing exterior walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade two or more coats @3.84kg/10sqm. |
| 10 | Providing and fixing 18mm thick gang saw cut mirror polished granite (premoulded and pre polished), machine cut for kitchen platform, vanity counters window sills facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 11 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion elded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge, PN-16 pipe, Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc :a) 16 mm OD |
| 12 | P/F of PPR fittings of standard quality and make(c-grade) including jointing/ testing complete a. PPR Union 20mm |
| 13 | Tank nipples 20mm dia |
| 14 | Providing and fixing of PPR gate value with C.I wheel of approved quality (ISI mark) : 25 mm nominal bore |
| 15 | P/F of following PVC pipes & fittings of standard quality & make (B type) Prince or equivalent incl.including PVC waste fittings (Collars, Tees's, Elbows etc.) jointing/testing complete a) 100mm dia |
| 16 | P/F of following PVC pipes & fittings of standard quality & make (B type) Prince or equivalent incl.including PVC waste fittings (Collars, Tees's, Elbows etc.) jointing/testing complete a) 75 mm dia |
| 17 | P/F PVC fittings of standard quality type : a) Floor Trap (100mm) |
| 18 | Tee (100mm) |
| 19 | Reducer 100mm to 75 mm |
| 20 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth,leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge.All kinds of soil : |
| 21 | Providing and Laying of stone soling/khakh bajri hand packed under floors/walls/lanes/drains etc including, ramming , and dressing complete. |
| 22 | Providing & Laying of stone dust/Moorum as binding material Including consolidation . |
| 23 | Constructing masonry Chamber 30x30x30 cm inside, in brick work in cement mortar 1:4 (1cement :4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. 19.26.1 With common burnt clay (non modular) bricks of class designation 7.5 |
| 24 | P/F of Gyser of Superior Quility 50 Leter |
| 25 | Providing and fixing of Shower 150mm |
| 26 | P/F CP Brass Bib Cock 15mm |
| 27 | P/F CP Floor Grating (100mm) |
| 28 | P/F CP Angle valve 15mm Nominal Bore concealed type Jaquar or Equivalent. |
| 29 | P/F PVC Water Storage Tank Tripple Layer Sintex or Eq Make |
| 30 | S/L of precast RCC rings of 7 inch width and 3'dia and 1.25 inch thick for soakage and septic tank incl earthwork in excavation, RCC cover in M20 grade with reinforcement for soakage pits & , incl. disposal of excavated earth beyond the site, disposed earth is to be leveled and neatly dressed incl. dewatering of trenches during execution. (if required). |
| 31 | Providing and fixing of 0.5 HP water motor of approved brand and quality, including installation, testing, and commissioning, including providing and fixing 20mm dia PPR pipes of 9mts length, complete with necessary fittings such as elbows, sockets, and clamps for the water connection to the main pipeline, including fabrication, supply, and fixing of a protective cage for the motor made of structural steel sections (angle iron, flat iron, etc. & CGI Cover) of appropriate size and thickness, with proper welding and painting securely fixed to the ground or a stable base, including electrical wiring connections and testing the system to ensure proper functioning. Complete Job in all respects as per directions of the engineer-in-charge. |
| 32 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch ( Anchor roma urban/ Eq. make), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required..( Havell/Legrand/Roma urban/ Eq. make as per ISI Standard ) |
| 33 | P/F of Curtain rods , curtains for doors and windows (Complete Job) |
| 34 | Providing and fixing of Exast Fan with complete job |
| 35 | Carraige of Sand from Source to Site. 14 Km Lead by MT |
| 36 | Add provisions for Scrapping of paint out side unforseen items. (to be paid as per actual Site Requirements) Total in Figures Excess(+) 1.0 Full Conversion INR 526000.82 526000.82 INR Five Lakh Twenty Six Thousand and Paise Eighty Two Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |