| 1 | SUB-HEAD 1--BDB,PDB,VTPN ETC |
| 2 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: Legrand/ ABB/ SIEMENS/ Schneider / L&T] |
| 3 | 4 way- Up to 160A |
| 4 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. [Make: Legrand/ ABB/ SIEMENS/ Schneider / L&T] |
| 5 | 160A FP |
| 6 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection. [Make: Legrand/ ABB/ SIEMENS/ Schneider / L&T] |
| 7 | 63A FP |
| 8 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealedin wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provisionfor earthing attachment. [Make: Legrand/ ABB/ SIEMENS/ Schneider / L&T] |
| 9 | 6 Way |
| 10 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. [Make: Legrand/ ABB/ SIEMENS/ Schneider / L&T] |
| 11 | 63A TP |
| 12 | 63A FP |
| 13 | 6-32A SP |
| 14 | Supplying and fixing 4 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment for two nos existing X-Ray machine [Make: Legrand/ ABB/ SIEMENS/ Schneider / L&T] |
| 15 | SUB-HEAD 2--Supplying & Laying of Cable |
| 16 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendment) |
| 17 | 4 CORE 95 SQMM |
| 18 | 4 CORE 70 SQMM |
| 19 | Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 20 | Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting |
| 21 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables incl. finishing end by crimping method incl solderless socket (Dowels make) as per GS as below : |
| 22 | 4 CORE 95 SQMM |
| 23 | 4 CORE 70 SQMM |
| 24 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 25 | 4 CORE 95 SQMM |
| 26 | 4 CORE 70 SQMM |
| 27 | SUB HEAD 3-- Distribution wiring |
| 28 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required |
| 29 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 30 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required |
| 31 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 32 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 33 | 25mm size |
| 34 | Finishing of thePVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 35 | 2.5 sqmm |
| 36 | 4 sqmm |
| 37 | 6 sqmm |
| 38 | 10 sqmm |
| 39 | SUB-HEAD 4 --Miscellaneous |
| 40 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. |
| 41 | 300x50x1.25mm (18SWG) With 25x25x3mm angle iron support |
| 42 | 150x50x1.25mm (18SWG) With out angle iron support |
| 43 | Supplying and fixing 415V, 160 A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc Make: L&T /Havells / Standard/ HPL/ Legrand/ ABB/ SIEMENS/ Schneider] |
| 44 | SUB-HEAD 5--AC,Timer & Starter |
| 45 | S&F of 250V, 25A timer controlled single starter for controlling Single Air Conditioning Machines in SS double door 2+10 way DB enclosure (L&T / ABB / Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm2 copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl. necessary connections as per direction of EIC : - |
| 46 | 25A DP MCB (L&T / ABB / Legrand make) – 1 no. |
| 47 | 24Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) – 1 no. |
| 48 | 3-pole power contactor (L&T make Cat no MNX22 / 250V) – 1 no. |
| 49 | 2-Modular AC motor starter (Legrand / Myrius Cat no 673031) – 1 no. |
| 50 | 1-Module 10A Modular switch (Make Legrand / Myrius) – 1 no. |
| 51 | 3-module plate with cover (Make Legrand / Myrius) – 1 no. |
| 52 | 25A Auto-Off-Bipass SPDT toggle switch (approved reputed make) – 1 no. |
| 53 | LED indication lamp (approved reputed make) – 1 no. |
| 54 | Outgoing bakelite connector 32A (Reputed make as approved by EIC) – 2 nos. |
| 55 | Supply & Fixing 240 V, 50 Hz, 1ph OLP 3+ starter with digital display for Split AC machine (1.5/2 Ton) having rated current 21 A Voltage range 160V-270V, IP 20, and provision to display voltage , current, and any fault indication (Make- Electron) incl. necessary connection (incl. supply material like wire, lugs etc if required) and commissioning the same. |
| 56 | SUB-HEAD 6--Earthing Installation |
| 57 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) |
| 58 | Earthing with 50 mm dia ISI-M GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as to GS. |
| 59 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 60 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 61 | SUB-HEAD 7--Dismentling the existing old panel & EI works |
| 62 | Dismentalling cost of existing panel, wires & fittings incl. mending good the damages as per direction of EIC. |
| 63 | Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees. Please Enable Macros to View BoQ information |