| 1 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10/14] |
| 2 | 4 Way Enclosure [Make: Legrand Enclosure (607715) or equivalent model of L&T/ABB/Siemens/Crabtree] |
| 3 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 4 | 2+16 way Enclosure [Make: Legrand Enclosure (607713) or equivalent model of L&T/ABB/Siemens/Crabtree] [D-9/13] |
| 5 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment |
| 6 | 2 Way [D-9/11] |
| 7 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand/Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6] |
| 8 | 40 Amp DP Isolator |
| 9 | 63 Amp FP Isolator |
| 10 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7] |
| 11 | (a) 6-32 Amps SP MCB |
| 12 | (b) 6-32 Amps DP MCB |
| 13 | Supplying and fixing 415V, 100 Amp TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.[ Make: L&T/ Havells/ Siemens/Standard] [D3:4(a)] |
| 14 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-Havells/RR Cable/ Polycab/Finolex) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan /call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish.[only PVC Rigid Conduit on ceiling and remaining portion concealed] |
| 15 | i) Average run 12 mtr [E-25/4(g)] |
| 16 | Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works |
| 17 | 25 mm dia 3 mm thick polythene pipe without earth continuity wire [E-2/4(a)] |
| 18 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-Havells/RR Cable/ Polycab/Finolex as approved by EIC) for ECC in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall for horizontal & vertical runs and in suitable size PVC casing-capping (Precision make) for ceiling portion only, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour as approved by E.I.C) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment flushed in wall incl. mending good damages to original finish [only PVC casing-capping on ceiling and remaining portion concealed] |
| 19 | 3 x 1.5 sqmm [E-9/C1(b)] |
| 20 | 2x 2.5 sqmm + 1x 1.5 sqmm as ECC [E-9/C1(s)] |
| 21 | 2x 4 sqmm + 1x 2.5 sqmm as ECC [E-9/C1(v)] |
| 22 | 2x 6 sqmm + 1x 4 sqmm as ECC[E-9/C1(y)] |
| 23 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9] |
| 24 | 2.5sqmm [F-5/9(i)] |
| 25 | 4 sqmm [F-5/9(ii)] |
| 26 | 6 sqmm [F-5/9(ii)] |
| 27 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. |
| 28 | 4 Module [E-17/F1(a)] |
| 29 | 6 Module [E-17/F1(b)] |
| 30 | 8 Module [E-17/F1(c)] |
| 31 | 2 Row 12 Module [E-17/F1(e)] |
| 32 | 2 Row 18 Module [E-17/F1(f)] |
| 33 | Supply & Fixing 240 V 6 A Modular type switch (Legrand: Mylinc/Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(a)] |
| 34 | Supply & Fixing 240 V 16 A Modular type switch (Legrand: Mylinc/Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)] |
| 35 | Supply & Fixing 240 V, 6 A, 5 pin Modular type plug socket (Legrand: Mylinc/Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)] |
| 36 | Supply & Fixing 240 V,16 A, 5 pin Modular type plug socket (Legrand: Mylinc/Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)] |
| 37 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand: Mylinc/Myrius/Arterior or equivalent model of Crabtree/ROMA ) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [E-18/10] |
| 38 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [C-3/21(a)] |
| 39 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. [C-3/21(b)] |
| 40 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. |
| 41 | 4 core 35 sqmm |
| 42 | Laying of cable from 4 core 35 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. [ F-1/2(c) ] |
| 43 | Supplying and fixing compression type gland and finishing the ends of following XLPE / PVC armoured AL. cable (2/4 / 3.5)Core as per GS. [F-4 & F-5] |
| 44 | 4 core 35 sq.mm. [[7(c)/F4 & 8(b)(xv) /F5]] |
| 45 | Add. G.S.T.@ 18% on total of item |
| 46 | Add. LWC.@ 1% on total of item Please Enable Macros to View BoQ information |