| 1 | AC work |
| 2 | OD286136/2025-2026:Supplying, installation, testing and commissioning of following nominal cooling capacity andISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS:1391: 1992 (PartI & II) with up-to-date amendments complete with indoor unit ,outdoor unit(condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerentgas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b.Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit,3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulatedwith nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/Bluestar:- 1.0TR single phase Inverter split A/C unit |
| 3 | OD286137/2025-2026:Supplying, installation, testing and commissioning of following nominal cooling capacity andISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS:1391: 1992 (PartI & II) with up-to-date amendments complete wit indoor unit ,outdoor unit(condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerentgas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b.Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit,3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulatedwith nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/Bluestar:- 2.0TR single phase Inverter split A/C unit |
| 4 | OD282289/2025-2026:Supply and Fixing of 4 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V V-Guard or its equivalen |
| 5 | OD286147/2025-2026:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unitwith voltage range of 175-275V and out put range of 210 - 250V (makeV-GUARD or its equivalent) |
| 6 | OD286149/2025-2026:Supply and installation for the Out door unit stand of Single phase 1 TR/1.5 TR/2TR Wallmounting split A/C unit. |
| 7 | OD286653/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe betweenout door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mmthick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge |
| 8 | OD282291/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge |
| 9 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm |
| 10 | OD282290/2025-2026:Supply and fixing of 25 mm dia pvc drain pipe and along with all required accessory in surface/recess including cutting the wall and making good the damages etc,as required |
| 11 | OD16366/2026-2027:Supply and fixing of 40 mm dia pvc drain pipe and along with all required accessory in surface/recess including cutting the wall and making good the damages etc,as required. Please Enable Macros to View BoQ information |