| 1 | Electrical Maintenance |
| 2 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 3 | OD35125/2026-2027:Dismantling existig damaged FL type Tube fittings and supply and fixing of new LED tube light on exisiting ROUND BLOCK/STIFF/CHAIN/WALL, 2 Nos 1200 mm LED lamps tube light fittings made of CRCA with 0.5mm thickness complete with all accessories and double side pin type single piece indoor LED Tube ,poly carbonate body (cool white at 6500 K temperature ) 1200 mm, G13 base Minimum 18 W with extruded aluminum heat sink with nominal system level lumen package of min 2100 Lumen / efficiency of minimum 115 lumen/watt, inbuilt Driver with THD 0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc and extruded Aluminium heat sink etc . The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification(LM 79& 80). Fittings directly fixed on wall or ceiling/RB/Stiff/Chain and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. |
| 4 | 1.43:Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 5 | OD35140/2026-2027:Charges Painting of stiff (fan/tube) in installed position with one or more coats of Brush paintingwith synthetic enamel paint of approved brand and Colour as required. |
| 6 | OD35126/2026-2027:Dismantling existig damaged FL type Tube fittings and supply and fixing of new LED tube light on exisiting ROUND BLOCK/STIFF/CHAIN/WALL, 1200 mm LED lamps tube light fittings made of CRCA with 0.5mm thickness complete with all accessories and double side pin type single piece indoor LED Tube ,poly carbonate body (cool white at 6500 K temperature ) 1200 mm, G13 base 18 W with extruded aluminum heat sink with nominal system level lumen package of min 2100 Lumen / efficiency of minimum 115 lumen/watt, inbuilt Driver with THD 0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc and extruded Aluminium heat sink etc . The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification(LM 79& 80). Fittings directly fixed on wall or ceiling/RB/Stiff/Chain and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. |
| 7 | OD357416/2025-2026:Supply,installation,testing and commissioning of 1800 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea pre-wired light fitting of all types complete with all accessories fixed to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. |
| 8 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 9 | 1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 10 | OD357417/2025-2026:Supply and fixing of 12W Mirror lamp warm white 3000k dimensions (LxDxH) mm 500x180x95 with RoHS compliant, duly wired up for use on 230 V AC supply and giving connection etc.including making good the damages, colour washing etc as required. Make -Philips or Equivalent) |
| 11 | OD357418/2025-2026:Supply, installation, testing and commissioning of 4000 lumen (1ft X 4ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled /Nichea pre-wired light fitting of all types complete with all accessories and fluorescent lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. |
| 12 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 13 | OD35133/2026-2027:Dismantling existing fan and Supply, installation, testing and commissioning of new 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 14 | OD357489/2025-2026:Supply, conveyance, installation , testing and commissioning of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 15 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 17 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 18 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 19 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 20 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 21 | 1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) |
| 22 | OD35177/2026-2027:Dismantling existing ordinary type tube /choke from fittings and Supply,Conveyance,installation, testing and commissioning of Minimum 18W LED pre-wired G13 base with extruded LED Tube poly carbonate body (cool white at 6500 K temprature ) 1200 mm, T8 I, Aluminium Heatsink having lumen pakage of 2100 Lumen /effiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. .( Make -Philips/Equivalent) |
| 23 | OD357484/2025-2026:Supply and fixing of 9W LED Bulb |
| 24 | OD35172/2026-2027:Charges for Painting of Exhaust fan in installed position with one or more coats of painting with synthetic enamel paint of approved brand and colour including checking bearing greasing and inter connections etc and tightening the connections etc as required |
| 25 | OD35173/2026-2027:Supply and replacement of Capacitor for Ceiling Fan |
| 26 | OD35174/2026-2027: Charges for Painting of single/double tube fittings,Round block and stiff in installed position including petty repairs with one or more coats of painting with synthetic enamel paint of approved brand and Colour by brush as required. |
| 27 | OD35175/2026-2027:Charges for dismantling the existing EI, complete, making good the damages of walls and conveying the dismantled materials to section store. Please Enable Macros to View BoQ information |