| 1 | Air Conditioning |
| 2 | OD87207/2024-2025:1) Charges for Servicing the following Air Conditioner Units such as cleaning using chemical materials and water. Cleaning air filter, attending petty repairs to copper tubes leak testing, rectifying defects if any and making the unit in proper working condition.-for Split (High Wall) type Units/for Split (floor mounting) type Units/for Ductable Split / cassette type: 1TR/1.5TR/2TR/3TR ( Each A/c unit service 4 times per year) |
| 3 | OD87208/2024-2025:All inclusive Comprehensive maintenance contract of the following air conditioner units including replacement of defective accessories as and when required including refrigerant control, pressure testing of the system, vacuuming oil charges, gas charging etc as required and excluding replacement of defective compressor, electrical main switches and civil works 8.5TR Air Cooled Ductable Split AC units with service of the plant 12 times per year. |
| 4 | OD87209/2024-2025:All inclusive Comprehensive maintenance contract of the following air conditioner units including replacement of defective accessories as and when required including refrigerant control, pressure testing of the system, vacuuming oil charges, gas charging etc as required and excluding replacement of defective compressor, electrical main switches and civil works.17TR Air Cooled Ductable Split AC units with service of the plant 12 times per year. |
| 5 | OD87210/2024-2025: Supply and installation of 4 pole power contractors IS/IEC 60947-4-1 & IEC 60947-4-1 , 16 A to 25 A |
| 6 | OD87211/2024-2025: Supply and installation of Fan leaf suitable for 1TR/1.5TR/2TR AC unit in the place of the defective one |
| 7 | OD87212/2024-2025:Supply and installation of copper condensing coil suitable for 1TR/1.5TR/2TR AC units in place of the defective one |
| 8 | OD30259/2026-2027:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7mm) 22 gauge |
| 9 | OD30260/2026-2027:Supply and fixing of 25 mm dia pvc drain pipe and along with all required accessory in surface/recess including cutting the wall and making good the damages etc., as required |
| 10 | OD30261/2026-2027:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.525 mm) and 5/8 inch (15.875 mm) 22 gauge |
| 11 | OD87213/2024-2025: Supply and installation of Fan leaf suitable for 3 TR AC unit in the place of the defective one |
| 12 | OD87214/2024-2025: Supply and installation of out door fan motor for 1TR/1.5TR/2TR AC unit in the place of the defective one |
| 13 | OD87215/2024-2025: Supply and renewal of Indoor Blower Motor suitable for 3TR/ 2TR/ 1.5TR/ 1TR AC unit, in place of the damaged one. |
| 14 | OD87216/2024-2025: Supply and installation of new capacitor 4 mfd or suitable for 1TR/ 1.5TR/ 2TR in place of the defective one |
| 15 | OD87217/2024-2025: Supply and installation of sensor suitable for 1TR/1.5TR/2TR/3TR AC unit, in place of the damaged one |
| 16 | OD87218/2024-2025: Supply and installation of PCB board suitable for 2TR/1.5TR/1TR in the place of defective one. |
| 17 | OD87219/2024-2025: Supply and install PCB board suitable for 3TR in the place of defective one |
| 18 | OD87220/2024-2025: Repairing of PCB board for following AC units:- 1TR/1,5TR/2TR/3TR |
| 19 | OD87221/2024-2025:Charges for filling sufficient quantity of Freon 22/ 410A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including brazing and make the compressor in good working condition for the following. 1TR/1.5TR/2TR/3TR AC unit, in place of the damaged one. |
| 20 | OD30090/2026-2027:Charges for Replacing the existing defective single phase 1.5 TR/2TR compressor units and Supply Installation Testing and commissioning of new compressors for single phase 1.5TR air-conditioning units ,providing necessary electrical and mechanical connections and making the units in good working conditions |
| 21 | OD35103/2026-2027:Painting /sticket Numbering of AC unit (same Number in indoor and out door ) Please Enable Macros to View BoQ information |