| 1 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. |
| 2 | M&L for brick work with old size bricks, straight or curved on plan n.exc 6m mean radius, built in cm 1:6 complete all as specified and directed. |
| 3 | M & L for except brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius with old size bricks in CM 1:6 complete all as specified and directed. |
| 4 | Taking down cement mortar plastering on brick or stone walls, etc. including raking out joints,hacking for key,scrubbing down with water, etc. |
| 5 | M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM (1:4) finished even and smooth without using extra cement mixed with water proofing compound. |
| 6 | M&L for two coats of cement base paint over chalk whitening newly plastered surfaces of walls including preparation of surfaces all as specified. |
| 7 | Dismantling of posts or struts(wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed ground all as specified and directed. |
| 8 | Dismantling of fencing wire mesh of any type complete all as specified and directed. |
| 9 | Dismantling of steel barbed wire of any type complete all as specified and directed. |
| 10 | Excavating in post holes (or similar holes) in soft loose soil each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm |
| 11 | M & L for cement concrete Type C2 1:3:6 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified. |
| 12 | S & F galvanized 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing & straining & fixing to any type of standards rails straining bolts including securing or tying at crossing with & provn of galvanized mild steel wire complete all as specified and directed. (Each line wire to be measured) |
| 13 | Supply and fix 10mm dia MS Round bars as in support of Chain Link Fencing all as specified. |
| 14 | Supply only chain link MS galvanized fencing of any size or type complete all as specified and directed. |
| 15 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire |
| 16 | S & F mild steel bolt screwed one end with hexagonal or square nuts & washers the other end enlarged not exc 15cm long dia of neck 12mm complete all as specified and directed. |
| 17 | M&L for posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 all as specified and directed. |
| 18 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. |
| 19 | M&L for Providing, cement concrete type B1 1:2:4 using (20mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses,parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all complete all as specified and directed |
| 20 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 21 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for .Note- Rate includes for reinforcement cutting as required to facilitate demolition. |
| 22 | M&L for providing RCC (1:2:4) using 20mm graded stone aggregate as in coping, slab supported on wall, beam, lintels etc complete all as directed by Engrin charge. Please Enable Macros to View BoQ information |
| 23 | M&L for providing RCC (1:2:4) using 20mm graded stone aggregate as in coping, slab supported on wall, beam, lintels etc complete all as directed by Engrin charge. Please Enable Macros to View BoQ information |