| 1 | Excavation in trenches not exc 1.5m wide & not exc 1.5m in depth for foundation etc or manholes & getting out hard/dense soil complete all as specified and as directed. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. |
| 3 | M&L cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 4 | S&F for mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc and flat iron fillets for securing wire mesh similar work Confirming to Fe-290 (Gde E-165) etc, complete all as specified and as directed. |
| 5 | S&F MS flat iron supports or stays for fixing chain link fencing, including nut, bolts, washers etc conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 6 | S&F mild steel screw bolts (machine made) diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 05 cm and n exc 10 cm long, complete all as specified and as directed. |
| 7 | S&F MS Round bars 8 mm dia and over cut to length bent to shape required and all as specified conforming to gde Fe 410-W (Gde.E-250) quality-A or Fe 290 (Gde-E-165)for securing chain link fencing, complete all as specified and as directed. |
| 8 | Material supplied Chain link MS galvanisd fencing, of size (75mm x 75mm) and dia of wire is 4mm complete all as specified, complete all as specified and as directed. |
| 9 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 10 | S & F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and as directed. |
| 11 | Supply and Laying dia 600mm Concertina coil reinforced punched (chorme rajor or blade wire) with barbed tape of 0.5mm thick galvanised steel sheet and core wire of dia 2.5mm high tensile steel wire complete all as specified and as directed. |
| 12 | Removing excavated material n. exc 50m & depositing where directed at a level n.exc.1.5m above the starting point complete all as specified and as directed. |
| 13 | M&L two coat of synthetic enamel paint over a coat of red oxide Zinc chorme on newly steel surfaces of any description,over 10cm in width or girth including preparation of surface, complete all as specified and as directed. |
| 14 | M&L for 2 coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description,not exc 10cm in width or girth complete all as specified and as directed. |
| 15 | M&L for providing Reinforced cement concrete M-30 (Design Mix) (20mm graded aggregates) in foundation,including rafts,footing,foundation beams,plinth beams, bases of coloumn complete all as specified and as directed. |
| 16 | M&L for providing Reinforced cement concrete M-30 (Design Mix) (20mm graded aggregates) as in coloumns,pillars,piers,posts and struts complete all as specified and as directed. |
| 17 | M & L for formwork to sides of concrete foundations,footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 18 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 19 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in reinforcement of fencing posts,colums,plinth beams in fencing complete all as specified and as directed. |
| 20 | All as per item No.19.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and as directed. |
| 21 | M&L 15 mm thick rendering on fair faces of concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 22 | M&L for prepration of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 23 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 24 | S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and connected items complete all as specified and as directed. |
| 25 | M&L Mild steel, plain, black sheet 1mm in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed. |
| 26 | Surface excavation n. exc. (not exceeding 30 cm deep and avg 15 cm deep) and getting out in hard/ dense soil complete all as specified and directed. |
| 27 | M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 28 | M&L 100mm thick PCC type C-2, 1:2:4 (40mm graded stone aggt) as in path, hard standing, parking floors etc. complete all as specified and as directed. |
| 29 | M&L for Finishing surface of concrete by brooming as in flooring complete all as specified and as directed. |
| 30 | Forming 12mm thick expansion joint filled with pre formed bituminous filler and top 30 mm primed and sealed with sealing compound grade A ( thickness of concrete slab 100mm complete all as specified and as directed. Please Enable Macros to View BoQ information |