| 1 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 2 | Demolition of cement concrete (unreinforced) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. |
| 3 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) of internal dia 300 mm, set in cement mortar complete all as specified and as directed. |
| 4 | Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) of internal dia 450 mm, set in cement mortar complete all as specified and as directed. |
| 5 | M & L for concrete bed to glazed stoneware pipes of internal diameter 300 mm, laid in trenches of depth upto 1.2 m in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed. |
| 6 | M & L for concrete bed to glazed stoneware pipes of internal diameter 450 mm, laid in trenches of depth upto 1.2 m in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed. |
| 7 | Supplying and laying reinforced concrete pipes with collars, 300 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 9 | Removing excavated material (soils) exceeding 250 m but not exceeding 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 10 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 11 | Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 12 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 13 | M & L for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed. |
| 14 | M & L except stone for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed. |
| 15 | M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 16 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed. |
| 17 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 50 mm thick laid in alternate panel, finished even and smooth without using extra cement complete all as specified and as directed. |
| 18 | Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 19 | Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 20 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. |
| 21 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 22 | M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed. |
| 23 | Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed. |
| 24 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.complete all as specified and as directed. |
| 25 | M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. |
| 26 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. |
| 27 | Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M40 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. |
| 28 | Providing and laying at or near ground level factory made kerb stone of any size, top bullnosed shape, made of M-25 (Design Mix) grade cement concrete, in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 29 | Preparation of newly or previously untreated brick, stone, concrete, asbestos cement or plaster surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer of the same manufacturer complete all as specified and as directed. |
| 30 | M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed. |
| 31 | Dismantling of wrought or mild steel work of any description not otherwise described into primary parts complete all as specified and directed. |
| 32 | S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and as directed. |
| 33 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 34 | M & L for laying full body vitrified matt finish paving tiles of size 300x300x10mm thick suitable for exterior areas, set and jointed in neat cement slurry and pointed in white cement mixed withpigment to match the colour of tiles, confirming as per IS 15622:2017, laid over and including 15 mm thick screed in CM 1:6, complete all as specified and directed. |
| 35 | M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 30 cm X 30 cm X 25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) complete all as specified and as directed. |
| 36 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 37 | Supply and laying flexible DWC HDPE pipe ISI UV resistant in trenches under floor, wall etc 100mm outer dia with thickness not less than 1.2mm for the protection of XLPE cable from nearest LT panel to DB, incl MS clamp complete all as specified and directed. |
| 38 | Supplying & laying in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 39 | Supplying & laying in trenches 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 40 | Supplying & laying in trenches 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 41 | Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor upto any size and upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit or for relaying complete all as specified and as directed. |
| 42 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 43 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 44 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 45 | S & F in replacement of terminal box made of PVC Box fix on pole by means of mild steel clamps with bolt and nuts, provn for cable entry for incoming and outgoing including MCB 6-32-1Nos and 4 way connector-1nos Amps necessary connection duly fixed with and including cable glands threaded tye IP65 made of polymide with lock nut complete all as specified and directed. |
| 46 | M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) single swan neck including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including preparing and painting on steel tubular swaged pole 410 SP-31 (9.0 metre long) including cross arms, GI brackets of approved size, PCC coping incl taking out old existing PCC pole with all accessories complete all as specified and as directed. comprising the following: -(a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions |
| 47 | BLANK |
| 48 | M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down existing GI bracket complete all as specified and as directed. |
| 49 | M & L for bracket made out of GI pipe 32 mm dia medium grade, 1.2 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down old unserviceable complete all as specified and as directed. |
| 50 | S & F in replacement PVC insulated 3 core in single PVC sheathing multistranded copper cable of size 1.5 sqmm sheathed, 1100 volt grade drawn through and including conduit/ casing caping of suitable size fixed on wall/ pole and making good disturbed surface complete all as specified and directed. |
| 51 | M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 52 | M&L for scrapping down and removing of old deteriorated paint from LT steel poles of 7.50 metre height above ground level, preparing surface for painting, applying two coat of aluminium paint upto full height of pole including MS clamps etc all as directed at site including providing 3 Nos band/straps (300mm wide each) with red post office box colour synthetic enamel paint at a distance 300mm from plinth block and marking of pole number serially with black synthetic enamel paint 2 meter above PCC block, letter should not be more than 4 cm high with 16 cm dia circle around the marked number, complete all as specified and directed. |
| 53 | Labour only for attending complaints of unserviceability of street/security lights, dismantling of street lights, checking fault, rectifying fault, removing carbon deposits from terminals and replacement of driver (if required), reassembling the street light and making the light functional, complete all as specified and directed.Notes: (i) Supply only of driver of LED light shall be measured and paid separately under respective item of BOQ.(ii) Contractor's electrician shall attend the complaint cell of AGE E/M to collect the complaints and making the lights functional within the timeline given by the Engineer-in-Charge but not more than two days from the receipt of the complaints, in case of failing which a penalty of Rs 200/- per day per complaint shall be imposed on the contractor for delay in rectification of street light faults.(iii) If the light is to be replaced, the same shall be measured and paid under respective item of BOQ and no payment under this item shall be made for the same |
| 54 | S & F in replacement miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. |
| 55 | S & F LED street lights nominal power 60 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700⁰K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 56 | S & F LED street lights nominal power 70 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 8200, lumen efficacy of minimum 120 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours with and including fixing at any height on building using 1.5 metre medium grade galvanized iron pipe bracket made of 32 mm nominal bore and necessary nuts, bolts, clamps and concreting and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 2.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 57 | S & F LED streetlight/ building security light nominal power 90 Watt, 230 V AC, outdoor type with aluminium pressure die-cast housing, polyester powder coated, IP 65/66 protection complete with in-built integrated electronic LED driver including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 58 | S & F LED flood lights nominal power 150 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 80 lumens per watt, built-in electronic LED driver (APFC) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65, beam angle of 120⁰ clear, CW available CCT of 5700⁰K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated white finish, life span of minimum 50000 working hours with and including fixing at any height on building using 1.5 metre medium grade galvanized iron pipe bracket made of 32 mm nominal bore and necessary nuts, bolts, clamps and concreting and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 59 | S & F LED street lights nominal power 70 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 7000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700⁰K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-781-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix \\"B\\" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 60 | S & F LED street lights nominal power 70 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 7000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700⁰K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-781-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix \\"B\\" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Please Enable Macros to View BoQ information |