| 1 | Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed. |
| 2 | M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC Casing & Caping double lock type of as required width (not less than 20 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 1.6/1.8 mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for one light point controlled by one 5 Amp switch one way complete all as specified and as directed |
| 3 | All as per item No. 02 here in before, but for one fan/exhaust fan point controlled by one 5 Amp all as specified and as directed. |
| 4 | All as per item No. 02 here in before,but for one bell/buzzer point controlled by one bell push 5 Amp all as specified and as directed. |
| 5 | All as per item No. 02 here in before, but for one light point controlled by two 2-way switches all as specified and as directed. |
| 6 | All as per item No. 02 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed |
| 7 | All as per item No 02 above, but with 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switch on the ndependent board complete all as specified and as directed. |
| 8 | M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit concealed in wall of as required size (not less than 20 mm in dia) ISI marked medium grade with all accessories of same grade fixed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed |
| 9 | All as per item No 8 here in before, but for one fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed |
| 10 | All as per item No 8 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed |
| 11 | M & L for point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium in concealed grade of as required size (not less than 20 mm in width) ISI marked with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed |
| 12 | M & L for Point wiring for flame proof fitting with 1100 Volts grade PVC insulated un-sheathed single core FRLSH cable with stranded copper conductor cable of size 2.5 Sqmm and PVC insulated un-sheathed single core FRLSH cable with stranded copper conductor cable of size 2.5 Sqmm for earth, drawn through and including ERW rigid stove enamelled steel conduit of suitable size but not less than 19mm dia with and including bends, elbow, coupling etc (duly approved by CMRI Dhanbad) and including junction box in cast aluminium LM-6 material as required and complete all as specified. |
| 13 | Cutting chases, pinning in brick walls/stone concrete block or slab walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth all as specified and as directed. |
| 14 | Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed. |
| 15 | M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) / PVC conduit as per site requirement of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit) |
| 16 | All as per item No 15 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed. |
| 17 | All as per item No 15 here in before, but two run of single core 6 sqmm and one run of 6 sqmm cables as earth continuity conductor all as directed.Note Item Sr No :- 15, 16, 17Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit) |
| 18 | All as per item No 15 here in before, but four run of single core 10 sqmm and two runs of 10 sqmm cables as earth continuity conductor all as directed.Note: Four runs of cable, two run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit) |
| 19 | S & F in repairs Switch Piano flush button single pole one way 5/6 A , 240 V complete all as specified and as directed |
| 20 | S & F in repairs modular Switch single pole one way 6 A, 1 module , 240 V complete all as specified and as directed |
| 21 | S & F in repairs modular Switch single pole one way 16 A,1 module, 240 V complete all as specified and as directed |
| 22 | S & F in repairs Bell push flush button, single pole, one way, 240 V, 5 A complete all as specified and as directed |
| 23 | S & F in repairs Modular Bell push single pole, one way, 240 V, 6 Amp,1 module, complete all as specified and as directed |
| 24 | S & F in repairs Switch Socket combination 3 pin , 5 Amp flush type, 240 V, complete all as specified and as directed |
| 25 | S & F in repairs Modular Socket outlet 3 pin, 6 Amp, 2 module , 240 volts, complete all as specified and as directed |
| 26 | S & F in repairs Switch Socket Combination 16A/5A, , 5 pin, 240 volts complete all as specified and as directed |
| 27 | S & F in repairs Modular Socket outlet 16A/6A, 5 pin, flush type universal, 240 voltscomplete all as specified and as directed |
| 28 | S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm three terminals 240 volts complete all as specified and as directed |
| 29 | S & F in repairs call bell/buzzer type AC, 230 volts, single pole all as directed |
| 30 | S&F in repairs stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed. |
| 31 | S&F in repairs stepped Modular electronic fan regulator flush type 120 W, 2 module on the existing board all as directed. |
| 32 | S&F in repairs stepped Modular electronic fan regulator flush type 120 W, 1 module on the existing board all as directed. |
| 33 | S&F in repairs PVC gang box (modular type) of 1or 2 Module size, recessed type for mounting modular switches, sockets, fan regulators etc., including fixing with screws, making necessary connections to existing electrical wiring, making good the disturbed wall surface with cement mortar, plastering and finishing with matching paint to existing background, complete all as specified and as directed. |
| 34 | S & F in repairs modular flush metal box fixed in 60 mm deep of following size fixed with screw for mounting modular switches, Sockets, fan regulators etc for existing elect arrangements and connected to the existing elect wires, making good the distrubed area with cement work and paints as same existing backgound all as directed.(Note :S&F New modular switches, sockets & fan regulators will be measured and paid separely)(a) Size of the boxes suitable for 1/2 module |
| 35 | All as per item No. 34 here in before, but Size of the box suitable for 3 module |
| 36 | All as per item No. 34 here in before, but Size of the box suitable for 4 module |
| 37 | All as per item No. 34 here in before, but Size of the box suitable for 6 module |
| 38 | All as per item No. 34 here in before, but Size of the box suitable for 8 module |
| 39 | All as per item No. 34 here in before, but Size of the box suitable for 12 module |
| 40 | S & F in repairs White inner, outer cover plate Modular type with frame, 2 module |
| 41 | Diito all as per item No 40 here in before but 3 module |
| 42 | Diito all as per item No 40 here in before but 4 module |
| 43 | Diito all as per item No 40 here in before but 6 module |
| 44 | Diito all as per item No 40 here in before but 8 module |
| 45 | Diito all as per item No 40 here in before but 12 module |
| 46 | S & F in repairs PVC Casing & Caping double lock type of as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc. complete all as specified and as directed. |
| 47 | S & F in repairs PVC conduit of 25 mm dia of ISI marked with all accessories of same grade fixed on wall/ceiling etc. complete all as specified and as directed. |
| 48 | S & F in repairs knob suitable for Rotary type Flamproof switch in LM6,15A single pole 230V complete all as specified and as directed. |
| 49 | Supply and fixing LED light fitting 18/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protectio with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. |
| 50 | S & F Energy efficient surface Mounted LED Luminire 20 watts , 230 volt , 50Hz AC, Decorative ultra slim linear LED lighting fixture with acrylic body, environmental friendly, energy efficient ready to use pack complete rewired, Premium 20 W LED batten and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable all as specified and directed by Engr-in-Charge. |
| 51 | S & F in repairs Energy efficient surface Mounted LED Luminire 10 watts 2' long,230 volt , 50Hz AC with acrylic cover with aluminium body extruded complete with all accessories incl necessary three core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed. |
| 52 | Supply and fixing in replacement of environmental friendly, ultra modern, energy saving, surface mounted/recess mounted, decorative light / square or round light 9 watt LED luminaire comprising of high brightness LEDs warm white or normal white, including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor including removing old, Make : Havells / philips/Bajaj/CG |
| 53 | S & F in repairs recess/surface mounting high lumen LED flat panel 2'X2' 36 Watt, white powder coated CRCA housing with highpower LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed. |
| 54 | S & F in repairs LED Bulb 15 watts 230 volts, 50 hz AC complete all as specified and directed by Engineer-in-Charge. |
| 55 | S & F in repairs recess/surface mounting high lumen LED flat panel 1'X1' of 15 Watt, white powder coated CRCA housing with high power LEDs ,aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed. |
| 56 | S&F in repairs LED batten 1x20 W inverter batten working on AC supply in normal mode and DC supply in inverter mode with inbuilt battery back up of upto 4 hours with high efficency ,high lumen output , 20 Watt LED 230 volt 50hz all accessories including integrated electronic driver complete all as directed. |
| 57 | Supply and fix in repairs inverter Bulb works on AC supply in Normal mode and DC supply in inverter mode, with inbuilt battery back up of upto 4 hours, high efficiency, high lumes output, LED bulb 9 W 240volts, 50Hz complete all as specified and directed. |
| 58 | S&F for bulb holder suitable for 6 A as per requirement ( batten/angle type) complete as directed by engr-in -charge. |
| 59 | S & F in repairs Switch Flameproof WP Rotary type with termination box in LM6,15A single pole 250V |
| 60 | S & F in repairs Flameproof Switch socket combination with termination box in LM6,16A single pole 250V |
| 61 | Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed. |
| 62 | S&F in repairs sheet metal enclosure with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified. |
| 63 | M&L in replacement for Sheet metal enclosure Verticle TPN distribution board, 415 volts 8 way, with provision of MCCB incomer of Capicity upto 250 Amps double door complete with appropriate size bus bar , all connections to be done with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB, MCCB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) |
| 64 | M&L in replacement for Sheet metal enclosure Verticle TPN distribution board, 415 volts 6 way, with provision of MCCB incomer of Capicity upto 200 Amps double door complete with appropriate size bus bar , all connections to be done with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB, MCCB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) |
| 65 | M&L in replacement for Sheet metal enclosure Verticle TPN distribution board, 415 volts 4 way, with provision of MCCB incomer of Capicity upto 125 Amps double door complete with appropriate size bus bar , all connections to be done with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB, MCCB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) |
| 66 | Supply and fix in repair MCCB 63 Amps, 16 KA,Adjustable type, 415 volts, FP, 50 Hz thermal magnetic release adjustable type complete all as specified and directed. |
| 67 | Supply and fix in repair MCCB 100 Amps, 16 KA,Adjustable type, 415 volts, FP, 50 Hz thermal magnetic release adjustable type complete all as specified and directed. |
| 68 | Supply and fix in repair MCCB 160 Amps, 36 KA,Adjustable type, 415 volts, FP, 50 Hz thermal magnetic release adjustable type complete all as specified and directed. |
| 69 | Supply and fix in repair MCCB 200 Amps, 36 KA,Adjustable type, 415 volts, FP, 50 Hz thermal magnetic release adjustable type complete all as specified and directed. |
| 70 | Supply and fix in repair MCCB 250 Amps, 36 KA,Adjustable type, 415 volts, FP, 50 Hz thermal magnetic release adjustable type complete all as specified and directed. |
| 71 | M&L in replacement for Sheet metal enclosure MCB TPN distribution board, 415 volts 4 way, with provision of MCB TPN as incomer of Capicity of upto 100 Amps double door complete with appropriate size bus bar , all connections to be done with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB, MCB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) |
| 72 | M&L in replacement for Sheet metal enclosure MCB TPN distribution board, 415 volts 6 way, with provision of MCB TPN as incomer of Capicity of upto 100 Amps double door complete with appropriate size bus bar , all connections to be done with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB, MCB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) |
| 73 | M&L in replacement for Sheet metal enclosure MCB TPN distribution board, 415 volts 12 way, with provision of MCB TPN as incomer of Capicity of upto 100 Amps double door complete with appropriate size bus bar , all connections to be done with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB, MCB and making good distributed wall surfaces to match with existing specification . (Note:- MCBs will be measured separately.) |
| 74 | M&L in replacement for Sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification. (Note:- MCBs will be measured separately.) |
| 75 | M&L in replacement for Sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification. (Note:- MCBs will be measured separately.) |
| 76 | S & F in repairs MCB 4P 40-100 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 77 | S & F in repairs MCB 4P 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 78 | S & F in repairs MCB TP 40 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 79 | S & F in repairs MCB SPN 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 80 | S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 81 | Taking down carefully ceiling fans of size 1200/1400 mm sweep at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as coupling bolt, capacitor holder,terminal adoptor,screws,nuts,spring washers for blade/body etc and replacement of components/accessories such as ball bearings,gun metal bushes,capacitor,canopy top& bottom, shackle clip assembly and assembling of all parts including fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. Please Enable Macros to View BoQ information |
| 82 | Taking down carefully ceiling fans of size 1200/1400 mm sweep at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as coupling bolt, capacitor holder,terminal adoptor,screws,nuts,spring washers for blade/body etc and replacement of components/accessories such as ball bearings,gun metal bushes,capacitor,canopy top& bottom, shackle clip assembly and assembling of all parts including fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. Please Enable Macros to View BoQ information |