| 1 | M&L for repair to alternator 110 KVA/100 KVA disconnecting electrical connection from site carefully and shifting for repair to workshop dismantling the complete alternator, starter winding carefully and rewinding of stator with super enamelled copper winding wire of existing size with insulation material and varnish. Re-assembling after repair and shifting to site and testing on load to the entire satisfaction of Engineer-in-Charge |
| 2 | Supply and replacement of self starter assembly 12 volt complete with battery lead and battery terminal suitable for 100 to 160 KVA DG Set all as directed by Engineer-in-Charge. |
| 3 | M&L for repair, overhauling of self starter 12 Volts including replacement of worn out clutch, repair to main AUX field coil, solenoid switch, carbon brushes, spring and rewinding of armature etc for 25 KVA to 63 KVA DG set all as specified and directed. |
| 4 | All as per Srl item No 3 here-in-before but for 100 KVA to 125 KVA DG Set all as specified and directed |
| 5 | M&L for repair /overhauling of dynomo including supply & replacement of new carban bush and re-winding of armature and testing on load of the DG set of capacity 100 KVA to 160 KVA all as directed by Engineer-in-Charge. |
| 6 | M&L for taking out existing non clog sewage pump, set of any type and size from sewage sump (alongwith existing column pipe) including all fittings complete all as specified and directed. |
| 7 | M&L for lowering of non clog sewage pump, set of any type and size in sewage sump (alongwith column pipe) including all fittings complete all as specified and directed. |
| 8 | M&L for disconnecting and taking out motor from non clog sewage pump, dismantling the burnt motor, rewinding the motor with super enamelled copper winding wire as per existing gauge, size including suitable insulation material cotton tape, varnish, insulation paper, sleeves and dry & baking making connections etc and assembling complete after repair installation, commisioning and testing to entire satisfaction working performance including replacing bearing for NDE & DE side of motors for the capacitiy 12.5 HP, 3 Phase, 415 Volt, complete all as specified and directed. (Note:- The repair of pump motor shall be carried out within 72 hours after intimation of breakdown to the contractor by means of whats up/ massage/phone calls/ letter etc. Contractor shall refixpump motor at existing position within 72 hours failing which a penalty of Rs. 2000/- per days will be levived on the contractor). |
| 9 | S&F in replacement of CI impeller sutaible for 12.5 HP sewage non clog pump set complete all as specified. |
| 10 | S&F in replacement of ball bearing as per sample for 12.5 HP sewage non clog pump set etc complete all as specified. |
| 11 | S&F in replacement MS tail piece, 15cm dia, length as required, both end flanged, with nuts bolt and rubber flanged complete in replacement of existing unserviceable tail piece all as specified and directed. |
| 12 | S&F in replacement rubber insertion gasket sheet 4 mm thick for flanged MS/CI/DI pipe of dia 80 mm in replacement of old damaged rubber gasket sheet all as specified and directed. |
| 13 | S&F in replacement rubber insertion gasket sheet 4 mm thick for flanged MS/CI/DI pipe of dia100 mm in replacement of old damaged rubber gasket sheet all as specified and directed. |
| 14 | Taking out, dismantaling the mono block pump motor, from foundation / site, transporting the same to workshop, taking out burnt winding wires by strip opening of 3 phase electric motor of any make, rewinding the motor with super enameled copper winding wire of existing gauge and quantity including varnishing insulation sheet cotton, glass sleave etc as required, reassembling,testing, transporting back to site from workshop, installing back and making connection and again testing for motor capacity 0.5 HP to 1 HP complete all as specified and directed (Note:- The repair of pump motor shall be carried out within 72 hours after intimation of break down to the contractor by means of whats up/ massage/ phone calls/ letter etc. Contractor shall carry out testing for smooth functioning of pump motor and refix the same in existing position within 72 hours failing which a penalty of Rs. 500/- per day will be levived on the contractor). |
| 15 | All as per Srl item No 14 here-in-before but for motor of capacity 2HP to 4HP |
| 16 | All as per Srl item No 14 here-in-before but for motor of capacity 5HP to 7.5HP |
| 17 | All as per Srl item No 14 here-in-before but for motor of capacity 10 to 12.5HP. |
| 18 | S&F mechanical oil seal for 12.5 HP, sewerge submersible motor & pump including taking down old unserviceable one all as specified and directed. |
| 19 | M&L in replacement battery lead acid type 180 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. |
| 20 | M&L in replacement battery lead acid type 150 AH, 12Volts 25 plates, maintenance free complate all as specified and directed. |
| 21 | M&L in replacement battery lead acid type 105 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. |
| 22 | M&L in replacement of PVC insulated battery lead stranded copper conductor of size 50 Sqmm suitable complete all as specified & directed . |
| 23 | Servicing of DG Set of 12.5 KVA capacity, Make kirloskar, Model D-9, Air cooled type by cleaning externally, taking out tapet cover and carrying out tappet setting including replacement of tappet cover gasket, tightening of all external fasteners, bolts, nuts etc., cleaning of benjo bolt filter of fuel feed pump, cleaning of fuel filters, oil filters and air filter including replacement of filter elements, engine oil, fan belts, engine hoses, worn out electric wiring, meters, including toping up of coolant, electrolyte of battery etc. all as required and directed for proper designed output of gen set.(Note:- Spares e.g. fuel filter element, oil filter element, air filter element, coolant, hose pipes, fan belts, meters etc. as required to be replaced shall be measured and paid seprately as \\"supply only\\". Minor parts e.g. bolts, nuts, washers etc. including necessary T & P and cleaning materials as required for servicing shall deemed to be included in the rate quoted by the contractor). |
| 24 | All as per Srl item No 23 here-in-before but for DG set of capacity 25 KVA to 30 KVA . |
| 25 | All as per Srl item No 23 here-in-before but for DG set of capacity 35 KVA to 100 KVA. |
| 26 | All as per Srl item No 23 here-in-before but for DG set of capacity 110 KVA to 160 KVA. |
| 27 | Supply only for pre filter and fine diesel filter element for 12.5KVA Gen Set all as specified and directed. |
| 28 | All as per Srl item No 27 here-in-before but for 25 KVA Gen Set. |
| 29 | All as per Srl item No 27 here-in-before but for 30 KVA to 35 KVA Gen Set. |
| 30 | All as per Srl item No 27 here-in-before but for 40 KVA to 63 KVA Gen Set. |
| 31 | All as per Srl item No 27 here-in-before but for 100 KVA to 160 KVA Gen Set. |
| 32 | Supply only for oil filter element for 12.5 KVA Gen Set all as specified and directed. |
| 33 | All as per Srl item No 32 here-in-before but for 25 KVA to 35 KVA Gen Set. |
| 34 | All as per Srl item No 32 here-in-before but for 40 KVA to 63 KVA Gen Set. |
| 35 | All as per Srl item No 32 here-in-before but for 100 KVA to 160 KVA Gen Set. |
| 36 | Supply only rubber coupling for 12.5KVA Gen Set all as specified and directed. |
| 37 | All as per Srl item No 36 here-in-before but for 25 KVA to 35 KVA Gen Set. |
| 38 | All as per Srl item No 36 here-in-before but for 40 KVA to 63 KVA Gen Set. |
| 39 | All as per Srl item No 36 here-in-before but for 100 KVA to 160 KVA Gen Set. |
| 40 | Supply only fan belt for 12.5KVA Gen Set of existing size all as specified and directed. |
| 41 | All as per Srl item No 40 here-in-before but for 25 KVA to 35 KVA Gen Set. |
| 42 | All as per Srl item No 40 here-in-before but for 40 KVA to 63 KVA Gen Set. |
| 43 | All as per Srl item No 40 here-in-before but for 100 KVA to 160 KVA Gen Set. |
| 44 | Supply only of hose pipe set with clamp for DG Set of 25 KVA to 35 KVA all as specified and directed. |
| 45 | All as per Srl item No 44 here-in-before but for 40 KVA to 63 KVA Gen Set. |
| 46 | All as per Srl item No 44 here-in-before but for 100 KVA to 160 KVA Gen Set. |
| 47 | Overhauling and calibration of FIP ( female iron pipe) assembly of 12.5 KVA capacity DG Set at an authorised workshop including replacement of worn out rings, plungers, damper plates, gasket etc including taking out, transporting, refitting, refixing & testing complete all as specified and directed. |
| 48 | Overhauling and calibration of FIP (female iron pipe) assembly of 25 KVA to 63 KVA capacity DG Set at an authorised workshop including replacement of worn out rings, plungers, damper plates, gasket etc including taking out, transporting, refitting, refixing & testing complete all as specified and directed. |
| 49 | M&L in replacement for topping up of water coolent in radiator of DG set TVS girling/volvo line or of equivelent make all as directed by Engineer-in-Charge. |
| 50 | M&L in replacement for engine oil of DG Set of 10W-30/ 20W40 or equivalent complete all as specified and directed by Engineer In charge |
| 51 | M&L for replacement of rectifire for the DG set of capacity 12.5 KVA to 100 KVA all as specified and directed by Engineer-in-Charge |
| 52 | M&L for replacement of rectifire for the DG set of capacity 110 to 160 KVA all as specified and directed by Engineer-in-Charge |
| 53 | S&F in replacement automatic voltage regulator suitable for DG set for 12.5KVA to 160KVA all as specified and directed. |
| 54 | Taking out the radiator assembly of DG set of 125 KVA capacity and transporting to work shop dismantling upper and lower tank and cleaning thoroughly, replacement of gasket packing , nuts, bolts, washers, descaling with appropriate chemical and brazing of damazed fins / tubes and reassembling & refixing in same position after testing complete all as specified and directed. |
| 55 | All as per Srl item No 54 here-in-before but for DG Set of capacity 100 KVA to 63 KVA. |
| 56 | All as per Srl item No 54 here-in-before but for DG Set of capacity 30/40 KVA. |
| 57 | M&L for replacement of battery terminals brass with steel nuts, bolts & washers all as specified and directed. |
| 58 | S&F in replacement of off load change over switches 100amp, TPN, 415 Volts with sheet steel enclosure with side handle complete all as specified and directed. |
| 59 | All as per Srl item No 58 here-in-before but 125 Amp. |
| 60 | All as per Srl item No 58 here-in-before but 250 Amp. |
| 61 | All as per Srl item No 58 here-in-before but 400 Amp. Please Enable Macros to View BoQ information |
| 62 | All as per Srl item No 58 here-in-before but 400 Amp. Please Enable Macros to View BoQ information |