| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur Name of Work : REPAIR/MAINT OF 33/11 KV INSTALLATIONS AND DITRIBUTION NETWORK, POWER TRANSFORMERS, EARTHING, CONTROL CABLES, VCBS, INSULATORS AND PANELS ALONGWITH CONNECTING WORKS IN CANTT AREA UNDER GE (I) KANPUR Contract No : GE(I)/KAN/T-15 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for HT / LT underground cable / pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed. |
| 3 | Returning filling of excavated soil after laying the cable with spreading leveling watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed. |
| 4 | Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed. |
| 5 | M&L for sand cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid. |
| 6 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 7 | M&L for drilling manually in soft/loose/ hard soil under road ,pavement hard standing for protection of GI pipe up to 80mm dia complete all as specified and directed. Note Depth of bore shall not be more than 1 Mtr from ground level. |
| 8 | Supply & laying in replacement of GI tubing of 80 mm bore dia, light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, on wall or pole incl fixing arrangement as directed, culvert etc of required length for cable protection complete all as specified and directed. |
| 9 | Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning complete all as specified and directed. Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. |
| 10 | All as per item No 8.00 above but HT 11 KV cable of size 120 Sqmm complete all as specified and directed. |
| 11 | All as per item No 8.00 above but HT 11 KV cable of size 185 Sqmm complete all as specified and directed. |
| 12 | Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed. |
| 13 | Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. |
| 14 | Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sq mm complete all as specified and directed. |
| 15 | Supply and fix cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. |
| 16 | Supply and fix cable straight through jointing kit for 11 KV (Earthed) grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed. |
| 17 | Supply and fix cable straight through jointing kit for 11 KV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. |
| 18 | S&F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 08 core cut to pieces including making all necessary connections as per site requirement and removing the old unsv control cables from ducts etc complete all as specified and directed. |
| 19 | S&F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 10 core cut to pieces including making all necessary connections as per site requirement and removing the old unsv control cables from ducts etc complete all as specified and directed. |
| 20 | S&F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 12 core cut to pieces including making all necessary connections as per site requirement and removing the old unsv control cables from ducts etc complete all as specified and directed. |
| 21 | Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable complete all as specified and directed. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required. |
| 22 | Dismantling & taking down old, deteriorated, switch air break and S&F with new 11 kV Isolator Double Stack, Horizontal Type, 400 Amp, each pole consist of galvanised steel base, HT insulators as per IS, non ferrous knife and spring loaded contact, arcing horns of adequate section to break the magnetizing current, including horizontal G.I. pipe adequate length for phase separation, adequate length of G.I. pipe of 32 mm for operation from ground level and operating handle complete in both OFF and ON position, jumpers with suitable conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontally mounting, supplied and fixed in repairs, complete all as specified and directed. |
| 23 | Dismantling & taking down old, deteriorated, switch air break and S &F with new 33 kV Isolator Double Stack , Horizontal Type, 400 Amp, each pole consist of galvanised steel base, H.T. insulators as per IS, non ferrous knife and spring loaded contact, arcing horns of adequate section to break the magnetizing current, including horizontal G.I. pipe adequate length for phase separation, adequate length of G.I. pipe of 32 mm for operation from ground level and operating handle complete in both OFF and ON position, jumpers with suitable conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontally mounting, supplied and fixed in repairs, complete all as specified and directed. |
| 24 | S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and directed.(Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Bracketsover 10 kg each to be measured under 'Structural Steel') |
| 25 | Servicing / Calibration to 11 KV HT VCB / SF-6/LBS/RMU complete including the following (a) Taking out 33 / 11 KV HT VCB / LBS/RMU of 400 /800 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB / SF6 trolley including opening the VCB / SF6 & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB / SF6 including connection to HT panel complete insulating oil to be replaced where reqd complete all as specified and directed.(b) Taking out relay set of any make from HT 33 / 11 KV VCB / SF6 panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. (Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately as supply only and cost for fixing of the same shall be deemed to included in quoted rates. Note : Minor spares if required shall deems to be included with the above job. |
| 26 | Supply only shunt trip coil assembly suitable for HT, SF6 / VCB, operating on 30 / 110 volt system and testing complete all as specified and directed. |
| 27 | Supply only closing / tripping coil operated on 110 / 30 volt system as per sample suitable for working of relay of HT SF6 / VCB complete all as specified and directed. |
| 28 | Supply only fabricated gears as required for spring charger of VCBs complete all as specified and directed. |
| 29 | Supply only vaccum circuit bottle as per existing make complete all as specified and directed. |
| 30 | Supply only Potential transformer as per existing size and make for 11 KV VCB / RMU complete all as specified and directed. |
| 31 | Supply only Current transformer as per existing size and make for 11 KV VCB / RMU complete all as specified and directed. |
| 32 | Supply only feeder protection relay for 33/ 11 KV incomer feeder panel complete all as specified and directed. |
| 33 | Supply only indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed. |
| 34 | Dismantling and taking out unserviceable DO fuse unit and supply and replace of DO fuse unit complete with insulators with metal fitting on both ends unit 11 KV complete all as specified and directed. |
| 35 | Supply & Fixing in replacement Pin type insulator porcelain, vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut, 100mm high & 65mm dia suitable for 11 KV grade working pressure fixed incl dismantling old complete all as specified and directed. |
| 36 | Dismantling from insulators and taking down ACSR conductor any size from HT/LT over head lines complete all as specified & directed. |
| 37 | S&F Aluminium conductor of any size with GI/steel reinforced complete all as specified and directed. |
| 38 | Taking down carefully transformer any capacity, any make, any type from pole / plinth by dismantling, dis-connecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site/store and shifting/refixing in other location under GE Kanpur after cleaning and making all electrical/earthing connections complete all as specified and directed. |
| 39 | M&L for disconnecting electrically and dismantling of LT Panel/RMU/ LBS at site and shifting/ refixing in other location and making all electrical connections complete all as specified and directed. Note : Cost of T&P / transportation is included in this item) |
| 40 | Dismantlling top cover of transformer 11/.440 KV of capacity upto 750 KVA , any make for repair / replacement of HT / LT bushing of transformer or for replacement of top cover gasket or for inspection of transformer or for minor internal repairs of transformer all including draining carefully transformer oil as required / upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed. |
| 41 | Dismantling old u/s HT 11 KV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 250 KVA complete all as specified and directed. |
| 42 | All as per item No 40.00 above but exceeding 250 KVA not exceeding 750 KVA complete all as specified and directed. |
| 43 | Dismantling old u/s LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 250 KVA complete all as specified and directed. |
| 44 | All as per item No 42.00 above but exceeding 250 KVA but not exceeding 750 KVA complete all as specified and directed. |
| 45 | Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket / seal , or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed. |
| 46 | M&L for taking out old burnt winding and rewinding of HT/LT coil of any type, capacity and make of transformer with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. complete all as specified and directed. |
| 47 | S&F in replacement of temperature gauge circular dial type of standard size and dia suitable for indoor/outdoor type transformer upto 750 KVA complete all as specified and directed. |
| 48 | M&L for replacement and full fill up fresh silica gel in assembly at site complete all as specified and directed. |
| 49 | S&F Top gasket made of 3mm thick cork sheet with suitable holes for 33/11/6.6/0.433 KV transformer of any type/capacity including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformer complete all as specified and directed. |
| 50 | Disconnecting electrically, open the cover of transformer any type/size and filteration and dehydration of Transformer oil for 33/11 / 6.6 / 0.433 KV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 KV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner. |
| 51 | Cleaning of transformer of size 63 KVA to 315 KVA outer surface suitable for painting and painting with two coat of synthetic enamel paint by spray machine of light grey colour or as directed including transformer accessories such as radiator, conservator tank, marshalling box and incl writing SM No/size/ feeder name etc complete all as specified and directed. |
| 52 | All as per item No 50.00 above but of transformer of size 315 KVA to 750 KVA complete all as specified and directed. |
| 53 | M&L for marking/writing feeder names/ SM No / MES No for HT/LT Electrical Eqpts like VCB, Tfrs, LBS / RMU/panels etc with synthetic enamel paint of Make Asian paints Ltd. Or Stickers equivalent of approved color complete all as specified and directed. |
| 54 | M&L for earthing with GI plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed. |
| 55 | S&F in replacement of HT 11 KV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work complete all as specified and directed. |
| 56 | Transportation of Transformer from site E/M yard to workshop for repairing and from workshop to site /E/M yard after repair etc of capacity upto 750 KVA complete all as specified and directed. NOTE : The rate deemed to be included of transportation charges. |
| 57 | Material and labour for dismantling of complete HV/LV coils of transformer upto 750 KVA (33/11/6.6/0.433 KV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV / LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed.Note : 1. Rewinding of defective HV / LV Coils shall be measured and paid seperately. 2. The rate deemed to be included of all tools and plants. |
| 58 | M&L Installation, commissioning, testing of transformer up to 750 KVA by connecting all HT 33/11/6.6/0.433 KV connections, earthing connections, control cables for various protections, indications, metering, connection and bezels connections and testing complete all as specified and directed. |
| 59 | S&F in replacement of fully retroreflective sign boards of cut to sizes/shape having writing back ground made out of 18 SWG MS Sheet duly painted with two coats of synthetic enamel paint over a coat of primer including marking/writing letters, road sign any type with radium tape in different colours, duly mounted on angle iron frame 45mm X 45mm and 5mm thick fixed with nut, bolt, washer and welding (height as per site requirement) etc and painting with two coats of black synthetic enamel paint over a coat primer including all necessary earth work and PCC for foundation complete all as specified and directed. |
| 60 | M&L for making for LBS operating handle and compartment key as per existing make of LBS complete all as specified & directed. |
| 61 | S&F in replacement of battery 12 volt 12 AH complete all as specified & directed. |
| 62 | S&F in replacement of battery bank consisting of 15 battery having cell capacity 100 Ah 2 volt complete all as specified & directed. |
| 63 | M&L for Open the cover of transformer any type/size on site and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 60 KV when tested at 4mm gap complete all as specified and directed. |
| 64 | M&L for advance maintenance free chemical earthing with enviornment friendly ring earthing system consisting each set of 03 (three) Nos of 10 (ten) feet length 40 mm dia earth eletrode made out by copper, maintenance free electrolytic grade copper earthing system based on flat in pipe technology of 3 Mtrs length , 40 mm dia with crystalite conductive mixture COMPOUND filled withthe permanent sealings at the top & bottom with the lead terminal / strip in 25x4 mm size copper with 2 holes of 10 mm dia at the top , to be lowered in 150 mm dia bore including filling of back fill ecofriendly earth enhancing compound tested by ROHS comply to IEC 62651-7 which should have passed leaching ,corrosion, supphur & resistivity test as per IEC 62651-7 by NABL accredit LAB/JAM plus compound in 150 mm bore in immediate contract around the earth electrode and top of the bore shall be finished with 40 mm thick PCC in 1:2:4 type B 1 over 75 mm thick PCC in 1:4:8 type D-2 and backfilly/ JAM compound shall be covererd with FRP pit cover of suitable size for each earth electrode , joint to be made by JAM weld exothermically welded technology including copper strip size 32 x 6 mm for earthing ring system and copper strip 32x6 mm size for earthing electrode to test point with saddles & porcelain insulators suitable size on wall ,earth strip protected by light grade GI pipe 40 mm dia in case of plinth protection / floor/ hard standing crossing complete all as specified and directed. Note :- Earth work , PCC work, PCC cutting work by cutter, earth chamber in suitable size with testing on suitable value etc rate shall deemed to be included in quoted rate |
| 65 | S&F in replacement of Current transformer (CTs) 33 KV outdoor type oil filled of ratio 100-30/5+5 class-1 for metering, class 5 P 10 for protection 15 VA burden suitable for protection metering and deferential protection mounted on extended frame of VCB and made up of hot dip galvanized steel structure. All control cables shall be terminated in junction box. Note :- (i). Cost of junction box and frame work used for CTs is deemed to be included in the rate quoted. (ii). Double core CT shall be provided one for protection (earth fault/over load) and one for measuring instruments. |
| 66 | S&F in replacement of single phase potential transformer (PTs) oil filled type of ratio 33KV/110 volts, class-1 suitable burden and mounted on hot dip galvanized steel structure, all control cables shall be terminated in junction box. Note : (i) Cost of junction box and frame work used for PTs is deemed to be included in the rate quoted. |
| 67 | Removing the cover of cable duct for removal of unwanted vegetation/bushes/small plants/ shrubs/soil from cable duct not exc 3' wide and 3' deep at 33 KV sub station and removing the excavated material to a distance exceeding 50 M and placing the cover after completion complete all as specified and directed. |
| 68 | Removal coarse aggregate of any size from MES installation and segregate/removal of vegetation/ bushes/ small plants/ shrubs etc and after that spreading in the same location incl levelling and removing the vegetation/ bushes/ small plants/ shrubs to a distance exceeding 50 M complete all as specified and directed. |
| 69 | M&L for coarse aggregate not less than 40 mm graded nominal size without any vegetation or chemical incl levelling spreading all around complete all as specified and directed. |
| 70 | M&L for lightening arrestor non linear resistor type confirming to Fe 410 W (gde -E-250) quality \\"A\\" complete line discharge class 3 nominal discharge current 10 KA station class & high discharge with stand 100 KA assembly suitable for 33 KV working pressure and mounted on hot dip galvanised steel structure including all clamp nuts bolt and washers etc connecting to earth 32 x 6 MM GI strip including taking out the same complete all as specified and directed. Note:- MS channel and angle shall be measured and paid seperately. |
| 71 | Supply and fixing in replacement to cabin assembly of silica gel suitable for step down transformer 11/ 0.440 capacity upto 630 KVA including excess water storage bottol , clamp including silicazel filled etc in existing make model sepcification in complete all as specified and directed. Note : Quoted rates shall be including the cost of silicalgel intially filling. |
| 72 | Supply & fixing PVC insulated sheathed aluminium conductor armoured cable with inner sheathing for service connection size 10 Sqmm 2 core 1100 Volt complete all as specified and directed. |
| 73 | Supply & fixing PVC insulated sheathed aluminium conductor armoured cable with inner sheathing for service connection size 6 Sqmm 2 core 1100 Volt complete all as specified and directed. |
| 74 | S&F LED board of size 15'X3'X4'' (L x W x H) made out of 24 guage GI sheet and front with acrylic sheet total enclosed with computerised letter writings of size not less than 100 mm as decided by Engr-in-charge and inside with 4x20w LED tube light complete with time control switch , MCB and battery back up with timer and synchronised motor board should be fix on 40mm dia medium grade GI pipe of 5' height board from Bldg roof ( 3' from the bottom of the board, 3' depth of the board and 1' embedded in PCC above Bldg roof), fixed in PCC 1:2:4 type B-1 using 20mm graded agg of size 450*450*600mm with complete wiring of 2 sqmm 3 core copper sheathed cable 10 meter long including service connection from the Bldg main DB by means of 25mm dia light grade pipe to the board. The cable inside the board shall run in PVC reinforced flexible conduit including PCC work for fixing of board on Bldg roof. The details to be written with computerised writing including taking down of old unsv board complete all as specified and as directed by Engr-in-Charge. |
| 75 | Supply and fixing glow sign board (box type) of size 1500 mm x 1200 mm x 200 mm cladding PGI sheet 18 gauge fixed on aluminium angle of size 25 mm x 25 mm x 3.00 mm on top/bottom both side and transfrant acrylic sheet 3.00 mm in front on which lay out of station HT electrical equipment and cables to be marked with different colours as directed complete with 4x20w LED tube light with wiring of 1.00 sqmm 3 core copper sheathed cable 10 meter long including service connection from the Bldg main DB by means of 25mm dia light grade pipe to the board |
| 76 | Supply & fixing self adhesive PVC insulation tape suitable for 11 KV, 25.1 MM x 9.1 Mtrs x 0.305 MM for HT Scotch-70 complete all as specified and directed. |
| 77 | Supply & fixing scotch Rubber mastic tape 2228, 2\\" (50 MM minimum) width and 10 feet in length suitable for 11 KV complete all as specified and directed. |
| 78 | M&L in replacement to Unsv of heavy duty saddle type porcelain type insulator for holding to GI / copper strip with bronze nuts bolts and washers etc all as site requirement complete all as specified and directed. |
| 79 | M&L in replacement of Air termination ,single pointed aluminium rod 12 mm dia 300 mm long complete all as specified & directed. |
| 80 | M&L in replacement of test point terminal block made of gun metal or phosphorus bronze size 75x 75x 25 drilled and screwed including 3 nos hex head screw complete all as specified & directed. |
| 81 | M&L in replacement of Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified & directed. |
| 82 | M&L in replacement of Galvanised iron strip 32x6 mm buried in ground for necessary connection complete all as specified & directed. |
| 83 | Cable route indicator made out of RCC patties size 15cm x 15cm x 75cm in lengths duly engraved with (HT CABLE 11 KV) with projection of 45 cm above ground level and 30 cm grouted in foundation including PCC foundation, RCC shall be painted with yellow colour above ground and HT CABLE 11 KV will be marked with Red Colour Paint complete all as specified and directed. |
| 84 | M&L painting to steel prepared surfaces of any width or girth not otherwise described by using synthetic enamel paint in two coats (one as finishing coat) over one coat of red oxide zinc chrome primer on surface of steel structure /girder/ angle frame/ wire mesh fencing etc in any description at E/M installation using paint spray gun on specified working pressure including sign making / marking with using different colour in given size of letter etc complete all as specified and directed.Note : Paint colour & shade including writing marking of letters etc shall be deemed included in quoted unit rate and the same shall be approved by Engr-in-charge) |
| 85 | M&L painting to external surface of old painted steel tubular pole upto 11 Mtr height in various location using aluminium paint in two coats (one as finishing) by spray gun after removing/ cleaning/ scraping etc to old fadded paint incl cross arm, support complete all as directed by Engineer in-charge at site and making alternating strip in 30 CM width each upto 1.5 Mtrs above normal ground level and marking pole numbers etc with all sign complete all as specified and directed. Note : Paint colour & shade shall be approved by AGE (I) and tree shrub cutting near poles shall be deemed included in quoted unit rate. |
| 86 | M&L Painting to existed PTs/ CTs /GOD/ run of ACSR in colour coding etc of 3 three phase distribution bay/ network of 33 KV yard from end terminating point to transformer HT leg/ studs using luminous paint for phase indication in colour coding (Red, blue and yellow) phase wise in two coats over one coat of red primer including cleaning /preparation/ removing etc to old paint on external surfaces of existed located protection equipment’s as above and marking as per given by Deptt complete all as specified and as directed. Note : Quoted rate shall be including the cost of painting to external surface of PTs/ CTs/ control panel in existed colour complete all as specified and directed. |
| 87 | Supply and fixing cable termination boots suitable size for RMU unit capacity 630 Amp including taking down old unsv termination boots complete all as specified and directed. |
| 88 | M&L for refilling of SF6 gas up to required working pressure for RMU unit capacity 630 Amp complete all as specified and directed. Note - Contractor should be provide all safety equipment to his staff before refilling of SF6 gas. |
| 89 | M&L for spread out chemical in 1500 sqm area to burn out the shrub/grass/ unwanted small trees etc in out fit area of electrical sub station located at AOR, 33 KV MRS and other E/M installations, mixed with water in given ration and spread by using spray gun in given time interval as directed. (Note: Chemical sample shall be supplied in sealed container after approved by Deptt and time interval between to spray period will be given by Deptt). |
| 90 | M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc as required of size 32 x 6 mm galvanised iron strip complete all as specified and directed. |
| 91 | Supply & fixing in replacement of 12 Volt 150AH,short tubular inverter battery with rugged construction maintenance free battery mounted on steel rack complete, testing and commissioning complete all as specified and directed. |
| 92 | Supply & replace battery lead of 1 mtre length, PVC insulated multistranded copper conductor of size 25 sqmm including one side cable lugs and other side battery terminal suitable to connect starter of any sizes of DG set complete all as specified and directed. |
| 93 | Supply and fixing Inverter 12 volt 900 VA max load 756 watt, inverter type pure sine wave inverter with digital display, processor intelligent 32 bit DSP processor MCB for protection from input main complete with mounting stand suitable for inverter and Battery complete all as specified and directed. |
| 94 | M&L for Calibration and testing of 33 KV Control and Relay Panel, to ensure physical healthiness with visual check for healthy tripping of over current and earth fault, adjusting tripping time, flag setting, ratio setting, instantaneous time setting etc as per installed capacity of transformer, short circuit current in accordance with percentage impedance of transformer including taking out the unserviceable parts / relays and making necessary alteration for fixing of the same in the existing panel complete all as specified and directed.Note:- (i) All the instruments and T & P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates.(ii) The all above checking ,inspection ,installation and testing work shall be performed by auth HT expert engineer. (iii) Spares and relays reqd for proper functioning of the system will be measured and paid seperately. (iv) Any other items necessary required for functioning of panel deemed to be incl in quoted rate. |
| 95 | Supply only Numerical Over Current Protection Relay, draw out type for 33 KV control panel complete all as specified and directed. |
| 96 | Supply only Master Trip Relay, draw out type for 33 KV control panel complete all as specified and directed. |
| 97 | Supply only Oil temperature and Winding temperature Relay for 33 KV control panel complete all as specified and directed. |
| 98 | Supply only Buchholz Relay for 33 KV control panel complete all as specified and directed. |
| 99 | Supply only PRV Relay for 33 KV control panel complete all as specified and directed. |
| 100 | Supply only Transformer trouble relay of control panel complete all as specified and directed. |
| 101 | Supply only Auxillary Relay for 33 KV control panel complete all as specified and directed. |
| 102 | Servicing / Calibration to 33 / 11 KV HT VCB / SF-6/LBS/RMU complete including the following (a) Taking out 33 / 11 KV HT VCB / LBS/RMU of 400 /800 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB / SF6 trolley including opening the VCB / SF6 & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB / SF6 including connection to HT panel complete insulating oil to be replaced where reqd complete all as specified and directed.(b) Taking out relay set of any make from HT 33 / 11 KV VCB / SF6 panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. (Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately as supply only and cost of fixing of the same shall be deemed to included in quoted rates. Note : Minor spares if required shall deems to be included with the above job. |
| 103 | Supply only shunt trip coil assembly suitable for HT, SF6 / VCB, operating on 30 / 110 volt system and testing complete all as specified and directed. |
| 104 | Supply only closing / tripping coil operated on 110 / 30 volt system as per sample suitable for working of relay of HT SF6 / VCB complete all as specified and directed. |
| 105 | Supply only fabricated gears as required for spring charger of VCBs complete all as specified and directed. |
| 106 | Supply only indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed. |
| 107 | Supply only contact or fixed contact blade for 33 kv gang operated switch, heavy duty and high conductive metal of capacity 200 / 400 amp complete with all accessories complete all as specified and directed. |
| 108 | Supply only MC 61 A Relay for 33 Kv control panel complete all as specified and directed. |
| 109 | S&F Male contact or moving contact blade for 33 kv gang operated switch, heavy duty and high conductive metal of capacity 200/400 amp with all accessories complete all as specified and directed. |
| 110 | S&F Tinned copper flexible jumper 200/400 amp for 33 kv gang operated switch complete all as specified and directed. |
| 111 | S&F Fix top / bottom contact suitable for 33 KV drop out fuse complete all as specified and directed. |
| 112 | S&F in replacement of aluminium Tee clamps heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar incl disconnecting and dismantling old complete all as specified and directed. |
| 113 | S&F in replacement of aluminium Pad connector heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar incl disconnecting and dismantling complete all as specified and directed. |
| 114 | S&F in replacement of aluminium PG clamps heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar incl disconnecting and dismantling old complete all as specified and directed. |
| 115 | S&F in replacement of aluminium Universal connector heavy duty suitable for panther/dog conductor at 33 KV sub station bus bar incl disconnecting and dismantling complete all as specified and directed. |
| 116 | S&F in replacement of aluminium Compression type connector stud type heavy duty terminal suitable for panther/dog conductor at 33 KV sub station bus bar incl disconnecting and dismantling old complete all as specified and directed. |
| 117 | S&F in replacement of four in series disc type insulator porcelain vitreous complete with all accessories, brown colour for working pressure 33 KV complete incl dismantling old complete all as specified and directed. |
| 118 | S&F in replacement of dropout fuse unit with double stack post insulators and channel, nut, bolt and washers etc all as required at site for 33 KV sub station complete incl dismantling old complete all as specified and directed. |
| 119 | M&L For Transformer LV and HV side cable connection box cover as existed as per OEM upto 750 kva complete with Nut and bolt all fixing arrangement complete all as specified and directed. |
| 120 | Supply and fix bus bar chambers 300 mm long iron clad with 4 Nos 200 Amp rated copper strips fixed flush wall and making good the disturbed wall surfaces all as a required at site complete all as specified and directed. |
| 121 | Supply and errect in true vertical position LT electric pole, Octogonal Pole, hot deep galvanised, with base plate of 220x220x12 mm thick, 07 Mtrs Long, top dia 70mm, bottom dia- 135mm, thickness of sheet- 3 mm, including Single arm GI bracket, inbuilt cable junction box with door, connection plate, MCB 6A, duly connecting existing LT UG cable, cable lugs, work included necessary earth work and RCC foundation as per manifacturers recommendation complete all as specified and directed.Note: Earth work, PCC foundation as per manufacturer recommendation included in the unit rate. |
| 122 | Supply and fixing AFO (Auto fire off) plastic fire extinguisher ball (orange colour) it can self active in the presence of fire, active within 3 to 5 seconds upon reaching the appropriate temprature and extenguish the fire, maintenance free for period 5 years, completely harmless to the human body, area cover 360 degree angle, area of about 70 to 80 sqft, it can be extinguish three classes of fire, solid, Liquid and electrical classes of fire, weight 1.50 Kg, 100% eco friendly, 100% bio-degradable along with fixing on wall accessories complete all as specified and directed. |
| 123 | Supply and fixing Fire extinguisher spray 50 ml aluminium body with stand, spray that works immediately on touch to keep small from growing dangerously out of control complete all as specified and directed. |
| 124 | Supply and fixing Eco fire ABC powder type 6 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook, ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified and directed. |
| 125 | Supply and fixing Eco fire ABC powder type 9 Kg fire extinguisher (red and black) effective for all type of fire with wall mount hook, ISI/ BIS marked, ISO & CE certified multipurpose use with 5 year warranty portable complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail