| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified & directed by Engineer-in-Charge. |
| 2 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 3 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge. |
| 4 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 5 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge. |
| 6 | Removing excavated material soil/disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge. |
| 7 | S&F and Testing of MNRE registered/approved Solar water heating system indirect type with heat exchange provision, Capacity 200 LPD with two compartments (100 Litre each) ,with elctric back up heater of suitable capacity to achieve temperature 60 to 80 degree C as per manufacturer design suitable flat plate collectors having insulation of rock wool/mineral wool 50 mm thickness at bottom & 25 mm thickness on sides with toughned ,tempered glass 4 mm thick & clading with alum sheet 26 SWG,hot water storage tank as per manufacturer's recommendation of suitable gauge stainless steel plate (having insulation of rock wool/ mineral wool 100 mm thickness & cladding with alum sheet 24 SWG) polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 200 LPD with minimum one year warranty alongwith MNRE registered/approved 200 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304 , with thermostat and heater coil 2/3 KW to achieve temperature 60 to 80 C and suitable size of MS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified & directed by Engineer-in-Charge.Note :- Solar hot water system includes cost of two FPC plates and backup stainless steel hot water tank to meet the 200 LPD capacity. Other items will be measured separately under respective items as below. |
| 8 | S&F and Testing of MNRE registered/approved Solar water heating system indirect type with heat exchange provision , Capacity 500 LPD with two compartments (250 Litre each) ,with elctric back up heater of suitable capacity to achieve temperature 60 to 80 degree C as per manufacturer design suitable flat plate collectors having insulation of rock wool/mineral wool 50 mm thickness at bottom & 25 mm thickness on sides with toughned, tempered glass 4 mm thick & clading with alum sheet 26 SWG,hot water storage tank as per manufacturer's recommendation of suitable gauge stainless steel plate (having insulation of rock wool/ mineral wool 100 mm thickness & cladding with alum sheet 24 SWG) polyester powder coated solar water heater Flat plate collector with high transmitive clear toughened glass glazing having absorber material as headers, risers and fins made up of 99.9% pure copper with selective black chrome coating with ultra sonic laser permanent bonding between copper fins & tubesell with inlet and outlet connections with collector top and bottom leg complete suitable for 500 LPD with minimum one year warranty alongwith MNRE registered/approved 500 LPD non pressurised FPC stainless steel hot water tank with inner tank material SS 304, with thermostat and heater coil 2/3 KW to achieve temperature 60 to 80 C and suitable size of MS powder coated stand 32x3 mm angle frame with required PCC work 1:2:4 for foundation/fixing complete all as specified and directed by Engr-In-Charge Note :- Solar hot water system includes cost of four FPC plates and backup stainless steel hot water tank to meet the 500 LPD capacity. Other items will be measured separately under respective items as below. |
| 9 | M&L for Gl steel tube medium grade galvanized with all fitting laid in trenches/ on wall/ ceiling/ roof complete including wall cutting, fitting of pipes and making good surface as per existing surface for the following sizes of complete all as specified and directed by the Engineer-in-charge. |
| 10 | 25 mm bore |
| 11 | 20 mm bore |
| 12 | 15 mm bore |
| 13 | S&F and replacement of the following sizes of gun metal gate vavle with iron wheel head screwed both ends for GI pipe complete and all as specified and dismentling old valve and deposited to MES store yard complete all as specified & directed by Engineer-in-Charge. |
| 14 | 25 mm bore |
| 15 | 20 mm bore |
| 16 | S&F Rotational moulded polyethylene water storage tank of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I complete all as specified & directed by Engineer-in-Charge. |
| 17 | S&F Rotational moulded polyethylene water storage tank of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed by Engineer-in-Charge. |
| 18 | M&L for MS Work i:e includes material, cutting, welding, other process for shaping of material to get into required shape as per site requirment and fixing on site complete all as specified & directed by Engineer-in-Charge. |
| 19 | S&F Plug type bib taps,cast iron, screwed for iron pipe of size 15 mm dia and fixed complete all as specified & directed by Engineer-in-Charge. |
| 20 | S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) of size 25 mm dia complete all as specified & directed by Engineer-in-Charge. |
| 21 | S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) of size 20 mm dia complete all as specified & directed by Engineer-in-Charge. |
| 22 | M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed by Engineer-in-Charge. |
| 23 | M&L for coloured Glazed ceramic tiles in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in epopxy grouting only to match over & including 10 mm thick rendering in cement mortar (1:4) complete all as specified & directed by Engineer-in-Charge. |
| 24 | S&F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified & directed by Engineer-in-Charge. |
| 25 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-Charge. |
| 26 | S & F for MCCB DB VTPN 12 way 415 V double door IP 54 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified & directed by Engineer-in-Charge. |
| 27 | S & F for MCCB DB VTPN 4 way 415 V double door IP 54 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified & directed by Engineer-in-Charge. |
| 28 | S & F MCCB 4P 415 volts 36 KA suitable for fixing on VTPN DB of capacity 400 Amps with extended terminals complete all as specified & directed by Engineer-in-Charge.Note:- Suitable size and frame of MCCB required as per existing DBs at site. |
| 29 | S & F MCCB 4P 415 volts 36 KA suitable for fixing on VTPN DB of capacity 250 Amps with extended terminals complete all as specified & directed by Engineer-in-Charge. Note:- Suitable size and frame of MCCB required as per existing DBs at site. |
| 30 | S & F MCCB 4P 415 volts 36 KA suitable for fixing on VTPN DB of capacity 200 Amps with extended terminals complete all as specified & directed by Engineer-in-Charge.Note:- Suitable size and frame of MCCB required as per existing DBs at site. |
| 31 | S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps with extended terminals complete all as specified & directed by Engineer-in-Charge.Note:- Suitable size and frame of MCCB required as per existing DBs at site. |
| 32 | S & F in repair/replacement for MCB DB TPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-Charge. |
| 33 | Supply and fixing MCB TPN 100 Amps, 240 Volts,10 KA rapturing capacity 'B' curve.complete all as specified & directed by Engineer-in-Charge. |
| 34 | Supply and fixing MCB TPN 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve. complete all as specified & directed by Engineer-in-Charge. |
| 35 | Supply and fixing MCB's single pole 40 Amps, 240 Volts,10 KA rapturing capacity 'B' curve complete all as specified & directed by Engineer-in-Charge. |
| 36 | Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'B' curve complete all as specified & directed by Engineer-in-Charge. |
| 37 | M & L in repair for submain wiring with approved colour code/as per IS (RYB,black & green for three phase) PVC conduit circuit with four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 16.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectional area of 16.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-Charge.Note :- Four runs of 16.00 Sqmm cable & one run of 16.00 Sqmm cable shall be paid as one unit length |
| 38 | M & L in repair for submain wiring with approved colour code/as per IS (RYB,black & green for three phase) PVC conduit circuit with four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectional area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-Charge.Note :- Four runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable shall be paid as one unit length. |
| 39 | M & L in repair for submain wiring with approved colour code/as per IS (RYB,black & green for three phase) PVC conduit circuit with four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectional area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-Charge.Note :- Four runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length. |
| 40 | M & L in repair for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-Charge.Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length. |
| 41 | Supply, laying and testing cable XLPE insulated ,screened ,PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 70 sq mm 3.5 core including taking down old existing unserviceable cable complete all as specified and directed by Engineer-in-Charge |
| 42 | Supply, laying and testing cable XLPE insulated ,screened ,PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 35 sq mm 3.5 core including taking down old existing unserviceable cable complete all as specified and directed by Engineer-in-Charge |
| 43 | Supply, laying and testing cable XLPE insulated ,screened ,PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 25 sq mm 3.5 core including taking down old existing unserviceable cable complete all as specified and directed by Engineer-in-Charge |
| 44 | Supply, laying and testing cable XLPE insulated ,screened ,PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 50 sq mm 3.5 core including taking down old existing unserviceable cable complete all as specified and directed by Engineer-in-Charge |
| 45 | S&F of AC Box having 20 Amp MCB SP enclosure as incomer complete all as specified & directed by Engineer-in-Charge. |
| 46 | M&L in repair of bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 15mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified & directed by Engineer-in-Charge. |
| 47 | M & L in repair of bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 25X3 mm GI strip as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified & directed by Engineer-in-Charge. |
| 48 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with 4.00 mm dia GI wire size complete all as specified & directed by Engineer-in-Charge. |
| 49 | M&L for GI Tubing light grade 15 mm dia.for cable protection complete all as specified & directed by Engineer-in-Charge. |
| 50 | M & L in repair HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of 40 mm dia complete all as specified & directed by Engineer-in-Charge. |
| 51 | M & L in repair HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of 50 mm dia complete all as specified & directed by Engineer-in-Charge. |
| 52 | S&F repair ,50 mm bore GI tubing \\"light garde \\"in treches on pole for protection of cables complete all as specified & directed by Engineer-in-Charge. |
| 53 | M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) complete all as specified & directed by Engineer-in-Charge. |
| 54 | Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 250 Amps complete all as specified & directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |