| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) including removal of debris to out side Mil Stn, complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 3 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground or lean concrete etc. complete all as specified and directed. |
| 4 | Demolition of stone/brick/concrete block masonry built in CM complete all as specified and directed. |
| 5 | Demolition of cement concrete un-reinforced any description in any position including removal of debris to out side Mil Stn, complete all as specified and directed. |
| 6 | Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed |
| 7 | Taking down cement plaster including tiles of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 8 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons Laid dry, bedded or pointed in any mortar etc including removal of debris to out side Mil Stn, complete all as specified and directed. |
| 9 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons Laid dry, bedded or pointed in any mortar etc including stacking and cleaning proper for reuse, complete all as specified and directed.Note: No extra payment shall be made for cleaning, sorting, stacking and safeguarding the tiles |
| 10 | Excavation post holes (or similar holes) in any type of soil each n exc 0.50 cum, incl getting out, complete all as specified and directed. |
| 11 | M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 12 | M&L RCC 1:1.5:3 type A-1 (using 20mm graded crushed stone aggregate) as in cover slab of drain, slab supported on walls/baffle wall, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 13 | M&L pre-cast cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in kerb stone on road side or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 14 | Providing precast cement concrete type B-0 1:2:4 (using 12.50mm graded crushed stone aggregate) as in louvres/jaffries and jallies, 25mm thick (measured solid) set in CM 1:6, including all mouldings but excluding frame of stone/brick/concrete complete all as specified and directed. |
| 15 | M&L, 75mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in sub base of flooring/interlocking tiles etc. complete all as specified and directed. |
| 16 | M&L 100mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in hard standing complete all as specified and directed. |
| 17 | M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed. |
| 18 | S&F mild steel as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting, welding or riveting etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 19 | All as per srl item No. 18.00 above but except mild steel work complete all as specified and directed.Note: Unit rate is also included locking holes after fixing of barbed wire and welding to bent protion complete all as specified and directed. |
| 20 | S&F galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanisd mild steel wire, staples or steel pins etc as directed (each line wire to be measured) complete all as specified and directed. |
| 21 | Restraining and resecuring including making good staples and tying with mild steel binding wire (whenever required) etc. in existing barbed wire fencing of any description complete all as specified and directed. |
| 22 | Supply & fixing in repair chain link fencing including line wires, any mesh, size and type to any type of straights, rails strading bolts etc including provision of binding wire complete all as specified and directed. |
| 23 | M&L preparation of new steel surfaces of any description and applying two coats of black bituminious paint wood, steel, iron, concrete, brick, stone etc. exceeding 10cm in width or girth complete all as specified and directed. |
| 24 | M&L preparing new surface of steel of any description, over 10cm width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed. |
| 25 | M&L preparing old surface of steel of any description, over 10cm width or girth not other wise described and applying a coats of synthetic enamel paint complete all as specified and directed. |
| 26 | M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius with old size bricks, built in Cement mortar 1:4, complete all as specified and directed. |
| 27 | All as per Sr item No 26.00 above but except bricks.Note: Old bricks obtained against demolition shall be used. |
| 28 | M&L walling of random rubble stone masonry uncoursed, brought up to course with best quality locally available harder stones such as granite, trap, basalt stone etc. well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed. |
| 29 | All as per srl item No. 28.00 above but except stone.Note: Old stone obtained against demolition shall be used. |
| 30 | M&L raised pointing to squared rubble stone masonry,un-courses or brought upto course in cement mortar 1:4 complete all as specified and directed. |
| 31 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 32 | Fixing only mild steel TMT CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.Note: Reinforcement steel shall be issued to the contractor from departmental store at free of cost as, complete all as specified and directed. The Contractor shall be fully responcible for loading, unloading, transpotation, safe custody, proper storage, cutting, bending and placing in position at site. No extra payment shall be admissible on this account, any loss, wastage or damage shall be recovered from the contractor as per rules. |
| 33 | Forming contraction (dummy) joint 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed. |
| 34 | M&L sand cushioning for paver block, watering and consolidation complete all as specified and directed. |
| 35 | M&L 60 mm thick rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size (shape as approved bt GE) laid in path,porch,hard standing or flooring etc conforming to IS-15658-2006, M-35 grade complete all as specified and directed . |
| 36 | All as per item No 35.00 above but except tiles. |
| 37 | M&L 80 mm thick rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size (shape as approved bt GE) laid in path,porch,hard standing or flooring etc conforming to IS-15658-2006, M-40 grade complete all as specified and directed . |
| 38 | All as per item No 37.00 above but except tiles. |
| 39 | S & F for PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber rings joints fixed to walls or floor of 75mm bore incl dismantling old unserviceable pipe any descriptions complete all as specified and as directed. |
| 40 | M&L coloured chequered cement concrete tiles, machine pressed, factory made of size 300 x 300 x25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 41 | M&L chequered cement concrete tiles, machine pressed, factory made of size 200x200x25mm thick, with grey cement and no pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 42 | M & L for preparation of old floor surfaces over 10cm in width or girth including cleaning the surfaces by wire brushes and washing and applying a coats of terracota colour acrylic antifungal exterior emulsion painting on floor of PCC Chequered tiles complete all as specified and directed. |
| 43 | M & L for Pavement floor vitrified tiles of size 300x300x10mm thick (Endura tiles of Johnson or equivalent makes listed in List of Makes) set, jointed and pointed in neat cement slurry and pointed with grey cement and pigment to match the colour of tiles in floor incl 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 44 | Cleaning of sewage lines of dia 100mm, 150mm, 200mm including blocked manholes by rodding from manholes and well flushing of blocked/ decomposed sludge/dirt, including disposal of sludge/waste other materials out side MOD land in closed container including removing and re-fixing manhole covers without damaging, complete as and when required basis, complete all as specified and as directed. Note :-(a) Two sewerman and one helper shall be detailed daily for the purpose of rendering the entire sewage system functional for 334 days. In case of failure compensation will be recovered at the double market rate of workers.(b) In case of blockage of sewage system the complaint shall be rectified within three hours from the time of intimation.(c) The rates quoted shall be deemed for attending day to day complaint basis and make functional the entire sewage system.(d) Rates quoted deemed to be inclusive of all T&P, shoes and uniform to sewerman. |
| 45 | Cleaning/clearance of blocked WC at any floor from WC to first manhole, blocked kitchen, bathroom, urinal and wash hand basin from main floor trap to gulley trap/first manhole inclduing disposal of sludge/waste out of defence land and burying the same in a pit complete all as specified and directed by Engr-in-Charge.Note: One sewerman shall be detailed daily to attend complaints for 11 months. |
| 46 | Cleaning of septic tanks including inlet, outlet chambers / manholes, any size / soak wells capacity by bailing out the water, taking out the sludge manually or mechanically (by tractor having sewage pump) and removing the waste material out of defense land and burying the same in a pit (including excavating) and covering the sludge / pit with soil complete all as specified and directed.(Note for item No 44,45 & 46:- Unit rate quoted shall deemed to be included of cleaning of surbs, grass small roots etc, around the septic tank, Soak wells, manholes and inspection chamber at adjacent to the pipe lines cleaning etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account). |
| 47 | Excavation in trenches in any type n.exc 1.5 mtr deep and 1.5 mtr wide and plan area n.exc 10 Sqm as in pits/col foundation etc complete all as specified and directed. |
| 48 | Returning, filling of soil incl watering & well ramming in layers, n.exc 25cm thick as in soil complete all as specified and directed. |
| 49 | Removal of surplus excavated soil to a distance n.exc 50 mtr & depositing at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. |
| 50 | Demolition & breaking up drain pipes (SGSW, PVC,AC or Reinforced concrete) set in cement mortar 100mm dia/150mm dia complete all as specified and directed. |
| 51 | Demolition & breaking up drain pipes (SGSW, PVC,AC or Reinforced concrete) set in cement mortar 200mm dia complete all as specified and directed. |
| 52 | Dismantling of cast iron or reinforced concrete drain pipes internal dia 75/100mm, jointed in cement mortar and taking out of wall or trenches, if required complete all as specified and directed. |
| 53 | Separating, scraping and cleaning of reinforcement steel (Demolition of concrete measured separately) |
| 54 | Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 55 | Taking down door shutter of any description exc. 1 sqm but not exc. 2 sqm each complete all as specified and directed. |
| 56 | Taking up or down 15 mm bore steel tubing and connections including complete all as specified and directed. |
| 57 | Taking up or down 20 mm bore steel tubing and connections including complete all as specified and directed. |
| 58 | Concrete bed to drain pipes 150mm dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 complete all as specified and directed. |
| 59 | Concrete bed to drain pipes 200mm dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 complete all as specified and directed. |
| 60 | M&L for 25mm thick cement concrete 1:2:4 type B0 (using 12.50mm graded stone aaggregate) in sub base, complete all as specified and directed. |
| 61 | M&L for 50 mm thick PCC 1:3:6, type C-1, using 20 mm graded aggregates as in plinth protection etc, finished even and smooth without using extra cement complete all as specified and directed. |
| 62 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation of man holes complete all as specified & directed. |
| 63 | Providing precast cement concrete type C1 1:3:6 (using 20mm graded agg) set in CM 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 64 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping). Complete all as specified and directed. |
| 65 | M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC slabs/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed. |
| 66 | S & F Salt-glazed stoneware drain pipes 150mm dia laid in trenches and jointed complete all as specified and directed. |
| 67 | S & F Salt-glazed stoneware drain pipes 200mm dia laid in trenches and jointed complete all as specified and directed. |
| 68 | M&L for glazed ceramic coloured tiles of size 350x 250x 7mm/ 450X 300X 7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile over rendering 10mm thick in cement mortar 1:3 on brick or concrete surface for fixing wall tiles as in dado complete all as specified and directed. |
| 69 | M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exc. 0.18 sqm in floors etc., set jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles incl 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 70 | M&L for 15mm thick plastering in cement mortar 1:4 on stone masonry surfaces or other than fair faces of brick surfaces, finished even and smooth without using extra cement, including WPC complete all as specified and directed. (Note :- WPC will be measured and paid separately) |
| 71 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finishing the surface even and fair without using extra cement including WPC complete all as specified and directed. (Note :- WPC will be measured and paid separately) |
| 72 | Supply only Liquid Water proofing compound complete all as specified and directed. |
| 73 | S&F for 15 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed. |
| 74 | Refixing old steel tubing 15 mm bore and connections in new or old position (walls/ceilings/floors etc) after cleaning complete all as specified and directed. |
| 75 | S&F for 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified and directed. |
| 76 | Refixing old steel tubing 20 mm bore and connections in new or old position (walls/ceilings/floors etc) after cleaning complete all as specified and directed. |
| 77 | S&F stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, for 100 bore pipe including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 78 | S&F in repair vitreous Chinaware squatting pan, 'Orrisa pattern' size 580 mm x 440 mm, white, with Cast iron 'P' or 'S' trap, front or back inlet, integral footrest complete all as specified, excluding flushing cistern and flush pipe), etc and making good to floors in repair, complete all as specified and directed. |
| 79 | S&F in repairs vitreous china ware wash hand basin white colour flat back of size 550x400mm including CI brackets, CP brass waste coupling 32mm and waste pipe etc complete all as specified and directed. |
| 80 | S&F in repairs oval shaped vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets and including, 32 mm bore waste CP coupling complete all as specified and directed. |
| 81 | S & F in repair Vitreous china wash down water closet pan 'pedestal pattern' white and trap including connection to drain (or outgoing pipe) and to flushing pipe, antisiphonage pipe etc seat and cover for pedestal pan , Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in posisition complete all as specified and directed. |
| 82 | S&F in repair single piece Suite white Vitreous china wash down water closet pan 'P or S trap' (pedestal pattern) with integral Vitreous china flushing vistern including plastic water closet seat and cover, complete all as specified and directed. |
| 83 | S&F in repairs vitreous china urinals,flat back of size 465mmX355mmX265mm,white with grating and union for discharge pipe including connecting to waste pipe complete all as specified and directed. |
| 84 | S&F 32mm dia flush pipe of polythelene of low or high density, for low or high level flushing cistern for padestal pattern water closet complete all as specified and directed. |
| 85 | S&F in repair PVC valve less, crystal white, syphonic action type flushing cistern 10 liter capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32mm dia PVC long bend flush pipe 90cm long and 15mm dia 450 mm ling PVC connection with CP brass coupling nuts and PVC washers at bothy ends fixed, in repairs, complete all as specified and directed. |
| 86 | S&F in repairs 15 mm Pillar tap cast copper alloy in single lever with capsten head chromium plated fancy type screwed down high pressure with or without letter hot or cold with long screwed shank and flynuts screwed for iron pipe and fixed in repairs complete all as specified and directed. |
| 87 | S&F in repair bib tap chromium plated cast copper alloy with capstan head wall flange screwed down screwed for iron pipe 15 mm bore complete all as specified and directed. |
| 88 | S&F 15 mm angle stop valve cast (male or female thread) copper alloy chromium plated with capstan head, wall flange screwed down screwed for iron pipe and fixed in repairs complete all as specified and directed. |
| 89 | S&F Cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints complete all as specified and directed. |
| 90 | All as per Srl item No. 89.00 above but refixing old pipe complete all as specified and directed. |
| 91 | S&F Cast iron soil, waste and vent pipes 75mm dia in any length with or without ears, with cement joints complete all as specified and directed. |
| 92 | All as per Srl item No. 91.00 above but refixing old pipe complete all as specified and directed. |
| 93 | S&F in repair 100mm bore CI floor trap with ss grating incl jointing to waste pipe with cement concrete 1:2:4 complete all as specified and directed. |
| 94 | S&F in repair 75mm bore CI floor trap with ss grating incl jointing to waste pipe with cement concrete 1:2:4 complete all as specified and directed. |
| 95 | S&F in repair 75mm bore CI bends (any radius) with ducks foot or heel rest complete all as specified and directed. |
| 96 | S&F in repair CI bends 100mm bore any radius diminishing piece or taper (Larger bore to be measured) complete all as specified and directed. |
| 97 | S & F for PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joinets fixed to walls or floor of 110mm bore with suitable MS clamps incl taking down old un serviceable pipe along with fittings any descriptions complete all as specified and directed. |
| 98 | S&F in repair PVC (SWR) bends any radius suitable for 110mm bore pipe provided with access door complete all as specified and directed. |
| 99 | S&F in repair 110mm PVC (SWR), Junction single, (Single T equal or unequal), fixed with solvent cement, with oval access door, complete all as specified and directed. |
| 100 | S & F for PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber rings joints fixed to walls or floor of 75mm bore with suitable MS clamps incl taking down old unserviceable pipe along with fittings any descriptions complete all as specified and directed. |
| 101 | S&F in repair PVC (SWR) bends any radius suitable for 75mm bore pipe provided with access door complete all as specified and directed. |
| 102 | S&F in repair 75mm PVC (SWR), Junction single, (Single T equal or unequal), fixed with solvent cement, with oval access door, complete all as specified and directed. |
| 103 | PVC (SWR) reducers 110x75mm, complete all as specified and directed. |
| 104 | S&F in repair 75mm pvc(SWR) vent cowl complete all as specified and directed. |
| 105 | S&F in repair 75 PVC (SWR) floor / nahani trap plain with ss grating, setting and jointing with solvent cement complete all as specified and directed. |
| 106 | M & L for PVC(SWR) gully trap 125/110 mm, setting and jointing with solvent cement including provision of 150 mm thick PCC 1:4:8 type D-2 (40 mm graded aggregate ) all round & at bottom of trap incl demolition existing unserviceable salt-glazed stoneware gully traps of any size including surrounding packing and concrete complete all as specified and directed. |
| 107 | S&F in repair of PVC connection pipe 15 mm dia 450 mm long with PTMT nut fixed in repairs complete all as specified and directed. |
| 108 | S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC Sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 109 | S&F factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded prelam colour PVC 'C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side Prelam PVC sheet to be fitted in the M.S frame welded/sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 110 | S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed. |
| 111 | S & F of 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 112 | S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed. Please Enable Macros to View BoQ information |