| Sl. No. | Item Description |
| 1 | Part I- CIVIL AND PLUMBING WORKS |
| 2 | Brick work with F.P.S.bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 4 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 6 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks). |
| 7 | Providing edge prefinished or moulding to 18mm thick marble stone counters, Vanities, Treads etc., including machine polishing to edge to give stone nature finish etc. complete as per design approved by Engineer-in-Charge.(Granite work) |
| 8 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete. |
| 9 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia. 0.5mm all complete. With 12mm uPVC or aluminum powder coated U beading |
| 10 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage o water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification and direction of engineer-in-charge Section of steel reinforcement and cross sections of uPVC profiles to be set as per design approved by Engineer -in charge. Wire mesh/ Glazing of plain /toughened/ laminated/ double glass unit with/ without high perfrmance coatings as per design requirements and conforming to IS:3548 and IS :16231 shall be paid seperately. Note :- Structural design proof checked from a government institute to be provided by the manufacturer for (i) sites with basic wind speed >45 m/ sec as per IS 875-Part 3 (ii) sites with structure height more than 20 m for all wind speeds |
| 11 | Two track two panel sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 12 | Using R 3 series with frame (55 mm and above) x(40 mm and above) and sash 930 mm and above) x( 55 mm and above) with Zink alloy (zamak) powder coated handle on every panel along with multi point locking system (height upto 1.8m) |
| 13 | Three track three panels sliding window with two glazed and one wire mesh panels with aluminium channel for roller track, wool pile, nylon rollers with SS 304 body |
| 14 | Using R 3 series with frame (98 mm and above) x(40 mm and above) and both glazed and fly screen sash (30 mm and above) x( 55 mm and above) with Zink alloy (zamak) powder coated handle on every panel along with multi point locking system (height upto 1.8m) |
| 15 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 16 | Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 17 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 18 | Providing & fixing glass panes with putty and glazing clips in upvc windows, windows, clerestory windows, all complete with : 5mm thick glass panes |
| 19 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as perIS : 4457, complete as per the direction of Engineer-in- Charge. |
| 20 | In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) |
| 21 | Acid and alkali resistant tile |
| 22 | In dado/skirting on 12 mm thick mortar 1:4 (1 acid proofcement : 4 coarse sand) Acid and alkali resistant tile |
| 23 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 24 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 25 | 11.41A.3.1 Size of Tile 600 x 600 mm sqm |
| 26 | Grouting the joints of flooring tiles having joints of 3 mm width, usingepoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge |
| 27 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 28 | Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 29 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 30 | 110 mm diameter |
| 31 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion. |
| 32 | Single tee without door 110x110x110 mm |
| 33 | Bend 87.5° 110 mm bend |
| 34 | 12 mm cement plaster of mix : |
| 35 | 1:4 (1 cement: 4 fine sand): |
| 36 | 15mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1cement: 4 fine sand) |
| 37 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications :13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm overand including one coat of Special primer applied @ 0.75 ltr/10 sqm sqm 193.70 |
| 38 | Painting wood |
| 39 | 13.52 Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer’s specifications including appropriatepriming coat, preparation of surface, etc. complete.13.52.1 On steel work sqm 241.75 |
| 40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 41 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 42 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 43 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 44 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge . concealed work including cutting chases and making good the walls etc., |
| 46 | 20 mm nominal outer dia .Pipes. |
| 47 | 25 mm nominal outer dia .Pipes. |
| 48 | 32 mm nominal outer dia .Pipes. |
| 49 | Providing and fixing uplasticised PVC connection pipe with brass unions: 45cm length and 15mm nominal bore |
| 50 | Providing and fixing CP Grating Square Grating, Size: 5\\"X5\\" SS304 Brand Onida Shape Square Material Stainless Steel Size 5\\" x 5\\"/6\\" x 6\\" Cat No 60/3025 Model No 5120/5121 125 mm nominal dia with 25 mm waste hole/without hole |
| 51 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III): 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4coarse sand (zone-III): 8graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1ement: 3coarse sand) finished with floating coat of neat cement and making |
| 52 | Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 53 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 54 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod ofapproved quality as per architectural drawings and dirUpto 5mm depth and 5 mm width |
| 55 | Providing and fixing soil, waste and vent pipes Slung piping ,vertical piping or horizontal piping in uPVC SWR pipings including all fittings , clamps hanging ropes and fasteners with or without doors . Only length is to be measured from GT , Manhole to Cowl or fittings. 75 mm dia |
| 56 | Providing and fixing soil, waste and vent pipes Slung piping ,vertical piping or horizontal piping in uPVC SWR pipings including all fittings , clamps hanging ropes and fasteners with or without doors . Only length is to be measured from GT , Manhole to Cowl or fittings. 110 mm dia |
| 57 | P/F CPVC union approved make CPVC pipes i/c cutting and making all complete as per the directions of Engineer-in-charge. |
| 58 | 32 mm nominal bore |
| 59 | Extra for providing 8mm thick float glass in place of 5mm thick glass |
| 60 | Extra for providing toughened glass pane instead of ordinary float glass panes in doors, windows and clerestory: |
| 61 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge |
| 62 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 63 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 64 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 65 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. |
| 66 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 67 | In cement mortar |
| 68 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 69 | From brick work in cement mortar |
| 70 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead : |
| 71 | Of area beyond 3 sq. metres |
| 72 | Dismantling wood work in frames, trusses, purlins and rafters up to10 metres span and 5 metres height including stacking the materialwithin 50 metres lead :15.14.1 Of sectional area 40 square centimetres and above |
| 73 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 74 | PART–II ELECTRICAL WORK |
| 75 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required:Group A |
| 76 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.:Group A |
| 77 | Wiring for twin control light point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 78 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 79 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 80 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 81 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 82 | Providing and fixing hexagonal fan box circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 83 | Supply and drawing following pair, 0.5 sq.mm. FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required.2 Pair |
| 84 | 2 Pair |
| 85 | Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc as required: 1or2 Module (75mmx75mm) |
| 86 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 87 | 25 mm |
| 88 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 89 | 15/16 amp switch |
| 90 | 6 pin 15/16 amp socket outlet |
| 91 | Telephone socket outlet |
| 92 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 93 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 94 | 1 or 2 Module (75mm x 75mm) |
| 95 | 8 Module (125mm x 125mm) |
| 96 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. |
| 97 | SITC of 10 watt mirror light fixture made of extruded aluminium housing suitable for 220 Volt AC with system lumens output of 2000 or higher colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) =50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd. |
| 98 | SITC of 1200mm (Nominal Size) LED luminaire of 36-40 watt made of extruded aluminium housing suitable for 220 Volt AC with system lumens output of 2000 or higher colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) = 50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd. |
| 99 | SITC of 12-15W LED surface Downlighter with a nominal system lumen output of 1300 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 Complaint,new backlit design . The luminaire should have a color temperature between 4000K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance etc complete as reqd. |
| 100 | Supplying, Installation, Testing and Commissioning of surface mounting IP-65, 10 Watt LED bulk head light fitting with polycarbonate diffuser, single phase, 100-270V AC, effiicacy 100 Lumens/ watt complete with integral electronic driver etc complete as reqd. |
| 101 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 102 | Supplying, Installation, Testing and Commissioning of following sizes Heavy duty Exhaust Fan with Aluminium Louvers including connection with 3 core PVC insulated PVC sheathed flexible copper conductor cable on the existing window opening / Structure / Box complete etc. as required: 300mm sweep 900 rpm.The exhaust fan shall be fixed on minimum 10 mm thick bakelite sheet having suitable opening for exhaust fan. |
| 103 | Part II- LAB COUNTERS IN CRCA STEEL AND ALLIED EQUIPMENT |
| 104 | CHEMISTRY WORK BENCH |
| 105 | Modular island Workbench with as per attached drawings and specifications- Table Dimension-133550mm W*1200 mm D*850 mm H, Over counter Storage Dimension-1500 mm L*400 mm D* 700 mm H |
| 106 | Laboratory Workstations in Plinth mounted designGeneral Description: Laboratory furniture must be tested as per SEFA-8M standards. All modular construction & design must be made of mainly skin passed/ zero spangle double skin pass CRCA steel sheet duly coated with at least 50 - 60 micron Epoxy Powder Coated in panel form and in CKD (Completely Knocked Down) construction. The design should have provision for reconfiguration for change in layout using simple tooling and should provide independent access to the utilities installed, electrical panel & instrumentation panel. It should be removable without removing other panels. All CRCA steel sheet components are of superior brand like TATA Steel / Posco/ Jindal/ SAIL and are fabricated by precision shearing, levelling, and notching, piercing, machines to achieve consolidated dimensions within close tolerances under the strict quality checks and assembled with the aid of fixtures. Exposed welding marks should be polished smooth to improve aesthetic. Corner intersections of vertical and horizontal members should in the same plane with bolted joints and should be suitably aligned. The height of Laboratory Work Stations should be 850 mm in metallic construction designed to have completely flexible modular system. Each module will have independent base frame. Necessary leg space are provided between two modules wherever required. Rear portion of the leg space are covered with the enclosure panel. Work table should consist of; a) SEFA-8 standards heavy duty under cabinets & drawers: SEFA-8 standards heavy duty under module, comprising of two shutters with two vertical x2 horizontal shelves under each sink unit of 750 mm width and - one shutter 375 mm wide -two horizontal shelves under each work top of 750 mm width- while remaining 375 mm under each worktop to be empty for maintenance space . |
| 107 | . Cabinet shutter will be in double skin construction and shall be provided with heavy duty, knuckle and barrel type SS hinges and positive catch arrangement. Shutter and drawer handles are also provided with recessed designed in Aluminum const. with pure epoxy powder coating. The under module shall be fabricated out of heavy gauge special grade CRCA steel sheet in weldless construction and shall be finished with pure epoxy powder coating for extra ordinary corrosion resistance. - Detailed specifications and thickness of CRCA items in each module: - Cabinet end panels; min. 1.0 mm thick CRCA steel sheet - Cabinet rear panel and top panel; min. 1.0 mm thick CRCA steel sheet - Cabinet base skid;1.0 mm thick CRCA steel sheet - Cabinet drawers; 1.0 mm thick CRCA steel sheet - Cabinet shutters & drawer front panels; double skin const, min 0.8 mm thick CRCA steel sheet - Cabinet main frame structure and drawer slide rails, 1.6 mm thick CRCA steel sheet - Each cabinet shall have self-standing type base skid plinth. |
| 108 | REMOVABLE BACK PANELS: These cover panels should cover the service lines (eg: for sink, Laboratory faucets, Valves etc. with complete pipeline for inlet and outlet for water supply, drainage , PNG and electrical Switch, Socket, etc with complete internal electrical wiring as per standard wherever required) that run through the middle for the island units. These should be easily removable (unclipped) and the service line should be accessed for maintenance. They should be made of CRCA STEEL of 1mm thickness with pure epoxy powder coating of 50-70 microns.COVER PANELS: All side cover panels and back panels, filler panels should be made from CRCA STEELpanels of 1.0 mm thickness with pure epoxy powder coating of 50-70 microns. |
| 109 | REAGENT SHELVES: Depending upon the layout it should be complete modular design consisting of 3 stage horizontal storage shelves made of minimum 1 mm thick CRCA STEEL with pure epoxy powder coating and having cutouts for electrical switches and sockets. Cutout for 3 module plate to be provided. All the members are knock down and can be restructured. The Reagent Racks vertical pillars should be made from CRCA STEEL of 1.6 mm thickness with pure epoxy powder coating with MS brackets of 2 mm thickness. There should be provision of installation of LED tubelight below the horizontal shelves for sufficient illumination on the working space.UNDER-BENCH STORAGE CABINETS:Welded cabinet body should be of flush face construction with intersection of vertical and horizontal members like LH and RH side panel along with front horizontal channel, back panel and bottom panel. It should have the provision for relocation anywhere easily as it should be an independent unit. Cabinet should be of square non-sharp edge construction. Doors should be assembled with SS-304 hinge assembly. Removable back panel should be provided to easily access the service lines running behind the cabinet benches. Intermediate horizontal channels should be provided between door and drawer. Shelf should be eight bend panel with 20mm thickness. Drawer tray – If needed- should be of single piece construction. Drawer should be well supported on LH and RH ball slide suspension system. Steel door and drawer front should be of double wall construction with sound dampening material filled inside. Doors should be easily removable, and hinges should be easily replaceable. The under-storage units should be ergonomically distributed at an alternative interval with leg space of same length as that of the under-storage unit. |
| 110 | Dimensions: The dimensions of the cabinets should be as per plan, Depth = 510mm.Configuration: The configurations should be , comprising of two shutters with two vertical x2 horizontal shelves under each sink unit of 750 mm width and - one shutter 375 mm wide -two horizontal shelves under each work top of 750 mm width- while remaining 375 mm under each worktop to be empty for maintenance space MOC: The entire material construction for the storage units should be CRCA Steel : IS 513 (1994). Thickness: LH/RH side panels, shutter front, Bottom panel, Top front, Drawer separator, shelf, Alignment channel should be of 1.2mm thk. Removable Back panel, Shutter cover, Fr. Rack strip, Top cover panel should be of 1mm thick. FINISH: The finish of the welded cabinets should be powder coated pure epoxy of thickness 50- 70 microns. Handles should be Anodized Aluminium Recessed-Type, CTC: 160.0 mm. LOCK: Units should have a locking facility with 180° cam lock mechanism. HINGES: Soft-closing type Hinges. Shutter should be of twin-type construction with sound dampening effect using profeel. Shutter cover should be equipped with Bump on for sound dampening. Ball Slide : for drawer units should be 400mm length.SERVICE FITTINGS AND ACCESSORIES: The service fittings (Sink, Faucet, Valve, Light fittings, Tube Light, Socket, Switch, drain board etc.) should be laboratory grade, and water faucets and valve bodies should be cast red brass alloy or bronze forgings or PTMT, all fittings should be powder plated unless specified otherwise. Fittings should be identified with service indexes in the color coding as per DIN 12920. |
| 111 | ELECTRICAL TRUNKING: The electrical trunking used for housing electrical switches and sockets, its top panel, bottom panel of the trunking should be made from 1.0 mm thick CRCA STEEL panel. It should be available in both, single sided and double-sided configurations. It should be made from CRCA STEEL with pure epoxy powder coating. The front surface that houses the electrical points should have a slope. The electric trunking unit should consist of Three Modular 16/6A switch socket MCB unitLABORATORY SINK AND ACCESSORIES: The sinks should be polypropylene molded construction made up of 5 mm thick high density and elastic poly propylene with good resistance to organic solvents. Bowl size should be 560 L x 350 W x 255 D mm. Faucet should be 3-way type. The worktop should be 19mm (+/- 2mm)thick Jet-Black Granite worktop. The exposed edges of the worktop should be chamfered and smoothened. The bottom of the worktop should be polished and there should be a V-groove throughout the length of the exposed edges to protect the cabinets from meeting the spillages. The overhang on the storage cabinet is 25 mm at the front side and 30 mm at the sides. The backing material used is a neoprene mat of 6 mm thickness. [NOTE : Supply and installation of laboratory furniture with necessary placement of sink, Laboratory faucet, valve etc. with complete pipeline for inlet and outlet and electrical Switch, Socket, light fittings etc with complete internal electrical wiring as per standard wherever required will be within the scope of theBidder/Agency. Source of Water inlet and waste outlet and Electricity Source will be provided within the room by buyer.] |
| 112 | SINK UNIT : Providing and Placing in position Sink Unit. Welded cabinet body shall be of flush face construction with intersection of vertical and horizontal members along with front horizontal channel, back panel and bottom panel. It shall be relocated anywhere easily as it should be an independent unit. Cabinet shall be of square non-sharp edge construction. Doors shall be assembled with soft closing hinge assembly. Door front shall be of double wall construction with sound dampening material filled inside. Doors shall be easily removable and hinges shall be easily replaceable. Thickness of side panels, shutter front, Bottom panel,Top front, should be of 1.2mm and for Shutter cover, Front Rack strip, Top cover panel shall be of 1 mm. Powder coating shall be pure epoxy with thickness of 50-70 microns. Anodized Aluminum Recessed- Type handles shall be provided. Providing and fixing PP Drop-In Sink with Anti-Siphon Bottle Trap and Flexible Serrated Connector to connect sink to the waste line, length 1metre. and 38mm Dia. Polypropylene Molded Sinks shall be made up of 5 mm thick high density and elastic poly propylene with good resistance toorganic solvents. Polypropylene Sinks (Drop-in) of overall size 560 L x 350 W x 255 D(mm), (Black color). Classic timeless appearance in matt finish, non rusting and easy to maintain with bottle trap. Providing and fixing 3-way outlet Water Faucet on each Sink Unit. The Faucet shall have 3 swan neck type water faucet made up of Brass with epoxy powder coating or PTMT . It should be PH and rust resistant, autoclavable and leak proof with at least 2 years of comprehensive guaraantee. The switch valve cast to be made of ceramic that can avoid acid wear. The outlet produced in PVC, has detachable hose nozzles, allay pressure, changeable high-pressure outlet constructed or normal clean outlet control of water flow faucet immediately |
| 113 | Demonstration Table with 2 base cabinet,(1 drawer & 2 shutters 2 no) .Table top:18 +/- 1 mm thick well-polished Jet Black Granite with half round nosing, acid-resistant, alkali-resistant .Material of Construction for Work Bench: 18G thick,CRC Sheet. Interior & Exterior will be provided with powder-coated finish. Under Bench Cupboards will be provided with Top Drawer and Bottom two Shutter with one Horizontal Partition. All necessary hardware fitting like Heavy Duty Drawer Channels for smooth rolling to be provided .All necessary hardware fitting like Heavy Duty Drawer Channels for smooth rolling to be provided,Table Dimension-2100mm W*750 mm D*850 mm H, Storage Dimension-600 mm W* 520 mm D |
| 114 | Glass Shutter Full Height cabinet (CRCA steel ) :Made of epoxy powder coated 18-20 gauge sheet,Dimension-1200 mm W x 500 mm D x 1800 mm H Dimension-1200 mm W x 500 mm D x 1800 mm H |
| 115 | Glass Shutter Full Height cabinet (CRCA steel ) :Made of epoxy powder coated 18-20 gauge sheet,Dimension-1500 mm W x 500 mm D x 1800 mm |
| 116 | Glass Shutter under counter cabinet (CRCA steel ) with grnite top : |
| 117 | Made of epoxy powder coated 18-20 gauge sheet, Dimension-1200mm W x 500 mm D x 850 mm H |
| 118 | PEG BOARD- Dimension- 550x400mm Material- Polypropylene |
| 119 | ALUMINIUM PARTITION- Providing and fixing full height single skin aluminium partition with 4mm thick float glass and 10mm thick prelaminated particle board combination. Fixing with required hardware and rubber gasket all complete. |
| 120 | EYE WASH- Material - Polypropylene Details - Eyewash stations target just the eyes and therefore have a lower flow requirement. ANSI Z358.1 recommends a flow of 0.4 gpm also at 30 psi. |
| 121 | Supply and Installation of Emergency Eye Wash with double spray-type outlet heads to deliver soft , wide , high volume spray of water . Outlet heads should have an internal self-regulating flow control, a reticulated polyurethane filter, a threaded spray cover and a hinged swing-away dust cover. Hinged cover should be permanently attached to outlet head body with a stainless-steel pin. All wearing components should be located inside spray head for ease of service. All emergency eye wash and shower equipment should be third party certified to comply with ANSI Z358.1-2009.WATER FITTINGS : Internal Water distribution line for the laboratories as per the BOQ . Providing and fixing of internal water connection to all the sink units with UPVC piping system.UPVC Pipe of Dia - 25 mm for Water Inlet and UPVC Pipe of Dia - 75 mm for Water Outlet. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail